Aliy Bespayev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aliy Bespayev has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Zh.Sh. Mukhanbetzhanova
Satbayev University
3 shared publications - Ilya Teschev
Department of Civil Engineering, Satbayev University, Almaty, Kazakhstan
1 shared publication - Natalya Ryvkina
Department of Heat, Gas Supply and Ventilation, I. Razzakov Kyrgyz State Technical University, Bishkek 720044, Kyrgyzstan
1 shared publication - Ulan Altigenov
Department of Civil Engineering, L.N. Gumilyov Eurasian National University, Astana, Kazakhstan
1 shared publication
Latest Publications
- Open Access
- 19 March 2024
- Published by Technobius in Technobius
- Vol. 4 (1) , 0051
Assessment of mechanical properties of elements modular block
This study presents the control test process to assess the bearing capacity, crack resistance, and crack opening width of the volume block ceiling slabs and the floor slab of the inter-block corridor. These parameters play an important role in ensuring the reliability and durability of buildings, especially when volumetric blocks are used in construction. The study's first phase focuses on the methodology of load-carrying capacity testing of ceiling slabs. The study's second phase focuses on the materials' crack resistance. The analysis of cracks in the material structure is a key aspect since cracks can lead to deterioration of its mechanical properties and reduced durability. The third stage of the study focuses on the crack opening width. This parameter is important in determining the criticality of cracks and their effect on structural integrity. The fourth stage of the study covers the analysis of the floor slabs of the interlocking corridor. Considering the peculiarities of loads and operating conditions in this context, tests analyzing the bearing capacity and stability of the slabs are carried out. The crack opening width reached 0.9 mm and the vertical deflections exceeded 50 mm, the deflection in the inter-block corridor floor slab before failure was about 11 mm. The test results indicate its sufficient strength, stiffness, and crack resistance. The study provides a deeper understanding of the properties and characteristics of materials used in construction and optimizes their use to improve the strength and durability of buildings.
- 19 March 2024
- Published by Technobius in Technobius
- Vol. 4 (1) , 0051
Open AccessAssessment of mechanical properties of elements modular block
This study presents the control test process to assess the bearing capacity, crack resistance, and crack opening width of the volume block ceiling slabs and the floor slab of the inter-block corridor. These parameters play an important role in ensuring the reliability and durability of buildings, especially when volumetric blocks are used in construction. The study's first phase focuses on the methodology of load-carrying capacity testing of ceiling slabs. The study's second phase focuses on the materials' crack resistance. The analysis of cracks in the material structure is a key aspect since cracks can lead to deterioration of its mechanical properties and reduced durability. The third stage of the study focuses on the crack opening width. This parameter is important in determining the criticality of cracks and their effect on structural integrity. The fourth stage of the study covers the analysis of the floor slabs of the interlocking corridor. Considering the peculiarities of loads and operating conditions in this context, tests analyzing the bearing capacity and stability of the slabs are carried out. The crack opening width reached 0.9 mm and the vertical deflections exceeded 50 mm, the deflection in the inter-block corridor floor slab before failure was about 11 mm. The test results indicate its sufficient strength, stiffness, and crack resistance. The study provides a deeper understanding of the properties and characteristics of materials used in construction and optimizes their use to improve the strength and durability of buildings.
- 15 June 2022
- Published by LLP International Educational Corporation in Bulletin of Kazakh Leading Academy of Architecture and Construction
- Vol. 84 (2) , 184-190
USING COMPOSITE PLASTICS FOR RESTORATION OF DAMAGED REINFORCED CONCRETE STRUCTURES
A method is proposed to restore the operational suitability of bent reinforced concrete structures with increased deflections and excessive crack opening. Modern methods of reinforcement by surface gluing composite fibro-reinforced plastics (FRP) on the stretched zone of exploited reinforced concrete structures increase the strength and rigidity of reinforcing elements, but do not reduce deflections and the width of crack opening. To restore the operational suitability of damaged reinforced concrete structures, a preliminary stress is proposed, which is used to strengthen FRP, which is provided by the creation of a temporary construction lift in the damaged elements.
- 15 June 2022
- Published by LLP International Educational Corporation in Bulletin of Kazakh Leading Academy of Architecture and Construction
- Vol. 84 (2) , 184-190
USING COMPOSITE PLASTICS FOR RESTORATION OF DAMAGED REINFORCED CONCRETE STRUCTURES
A method is proposed to restore the operational suitability of bent reinforced concrete structures with increased deflections and excessive crack opening. Modern methods of reinforcement by surface gluing composite fibro-reinforced plastics (FRP) on the stretched zone of exploited reinforced concrete structures increase the strength and rigidity of reinforcing elements, but do not reduce deflections and the width of crack opening. To restore the operational suitability of damaged reinforced concrete structures, a preliminary stress is proposed, which is used to strengthen FRP, which is provided by the creation of a temporary construction lift in the damaged elements.
- 15 June 2022
- Published by LLP International Educational Corporation in Bulletin of Kazakh Leading Academy of Architecture and Construction
- Vol. 84 (2) , 263-269
METHOD OF REINFORCING REINFORCED CONCRETE STRUCTURES DAMAGED UNDER DIFFERENT FACTORS
Methods for designing surface reinforcement of normal and inclined sections of bent reinforced concrete elements under normal operating conditions are outlined. Methods for restoring damaged reinforced concrete structures are proposed, including the use of prestressing with fiber-reinforced plastics. Data on the effectiveness of the restoration of damaged reinforced concrete structures are given.
- 15 June 2022
- Published by LLP International Educational Corporation in Bulletin of Kazakh Leading Academy of Architecture and Construction
- Vol. 84 (2) , 263-269
METHOD OF REINFORCING REINFORCED CONCRETE STRUCTURES DAMAGED UNDER DIFFERENT FACTORS
Methods for designing surface reinforcement of normal and inclined sections of bent reinforced concrete elements under normal operating conditions are outlined. Methods for restoring damaged reinforced concrete structures are proposed, including the use of prestressing with fiber-reinforced plastics. Data on the effectiveness of the restoration of damaged reinforced concrete structures are given.
- Open Access
- 28 April 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (1 (116)) , 81-86
Strengthening and restoration of damaged reinforced concrete structures with composite plastics
This paper considers directions to devise methods for restoring the operational suitability of reinforced concrete structures. Mistakes of designers and non-compliance with the concreting technology of monolithic reinforced concrete structures lead to the formation of cracks and deflections of unacceptable size in reinforced concrete beams and floor slabs, as well as to insufficient strength of the elements. Such structures require not only an increase in bearing capacity but also the restoration of the operational suitability of damaged structures. A technique for restoring the serviceability of bendable reinforced concrete structures with increased deflections and excessive crack opening is proposed. To restore bendable reinforced concrete structures, surface reinforcement with pre-stressed fiber-reinforced plastics is suggested, which is ensured by the creation of a building lift in the damaged elements. Fiber-reinforced plastics have a high strain modulus, elastic nature of the diagram, and increased frost resistance; they tolerate fatigue effects well and are resistant to the effects of chemically active substances. Unlike conventional reinforcement methods, surface reinforcement techniques are characterized by high gain efficiency, corrosion resistance, low labor intensity, and short terms of work; they ensure strength increase and provide for economic feasibility. This study's results established that the use of fiber-reinforced plastics not only increases the bearing capacity of reinforced concrete structures but also helps reduce the width of the cracks formed. Thus, it is possible to avoid an increase in the cross-section of structures and reduce the time of operations, which could lead to additional costs
- 28 April 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (1 (116)) , 81-86
Open AccessStrengthening and restoration of damaged reinforced concrete structures with composite plastics
This paper considers directions to devise methods for restoring the operational suitability of reinforced concrete structures. Mistakes of designers and non-compliance with the concreting technology of monolithic reinforced concrete structures lead to the formation of cracks and deflections of unacceptable size in reinforced concrete beams and floor slabs, as well as to insufficient strength of the elements. Such structures require not only an increase in bearing capacity but also the restoration of the operational suitability of damaged structures. A technique for restoring the serviceability of bendable reinforced concrete structures with increased deflections and excessive crack opening is proposed. To restore bendable reinforced concrete structures, surface reinforcement with pre-stressed fiber-reinforced plastics is suggested, which is ensured by the creation of a building lift in the damaged elements. Fiber-reinforced plastics have a high strain modulus, elastic nature of the diagram, and increased frost resistance; they tolerate fatigue effects well and are resistant to the effects of chemically active substances. Unlike conventional reinforcement methods, surface reinforcement techniques are characterized by high gain efficiency, corrosion resistance, low labor intensity, and short terms of work; they ensure strength increase and provide for economic feasibility. This study's results established that the use of fiber-reinforced plastics not only increases the bearing capacity of reinforced concrete structures but also helps reduce the width of the cracks formed. Thus, it is possible to avoid an increase in the cross-section of structures and reduce the time of operations, which could lead to additional costs