Chien-Jung Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chien-Jung Chen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Fu-I Chou
Department of Electrical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
1 shared publication- Fu-I Chou
Department of Electrical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
1 shared publication - Jyh-Horng Chou
Department of Healthcare Administration and Medical Informatics, Kaohsiung Medical University, Kaohsiung, Taiwan
1 shared publication - Yu-Cheng Liao
Department of Electrical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
1 shared publication
Latest Publications
- Open Access
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 39728-39736
Optimal Design of the Cascade Controller for Reheating Furnace by Taguchi Method
Reheating furnaces are used to uniformly heat billets (blooms, billets, or slabs) to between 1000°C and 1300°C before hot rolling. Cascade control is widely used in temperature controllers of the reheating furnace. Unfortunately, the relationship between temperature indicator controllers (TIC) and flow indicator controllers (FIC) usually changes with a single slope. It means that temperature load disturbances cannot be effectively resolved. In this study, the relationship between TIC and FIC is proposed to be nonlinear with multiple slopes, which is used to accelerate the temperature response and increase the temperature stability under high or low load conditions. The temperature controller parameters are more diverse, so this study optimizes the temperature controller parameters and determines the characteristic curves between TIC and FIC effectively and quickly by using the Taguchi method. The performance of the multi-slope method and the single-slope method is evaluated in an actual heating furnace. The experimental results show that the proposed method in this study improves the mean square error and standard deviation by 33.76% and 22.44%, respectively. After commissioning, the parameter combination (including the characteristic curve) has a remarkable performance in the heating zone, which can be used to reduce temperature disturbance, accelerate the temperature response, and increase temperature stability in the reheating furnace.
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 39728-39736
Open AccessOptimal Design of the Cascade Controller for Reheating Furnace by Taguchi Method
Reheating furnaces are used to uniformly heat billets (blooms, billets, or slabs) to between 1000°C and 1300°C before hot rolling. Cascade control is widely used in temperature controllers of the reheating furnace. Unfortunately, the relationship between temperature indicator controllers (TIC) and flow indicator controllers (FIC) usually changes with a single slope. It means that temperature load disturbances cannot be effectively resolved. In this study, the relationship between TIC and FIC is proposed to be nonlinear with multiple slopes, which is used to accelerate the temperature response and increase the temperature stability under high or low load conditions. The temperature controller parameters are more diverse, so this study optimizes the temperature controller parameters and determines the characteristic curves between TIC and FIC effectively and quickly by using the Taguchi method. The performance of the multi-slope method and the single-slope method is evaluated in an actual heating furnace. The experimental results show that the proposed method in this study improves the mean square error and standard deviation by 33.76% and 22.44%, respectively. After commissioning, the parameter combination (including the characteristic curve) has a remarkable performance in the heating zone, which can be used to reduce temperature disturbance, accelerate the temperature response, and increase temperature stability in the reheating furnace.
- Open Access
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 33362-33369
Temperature Prediction for Reheating Furnace by Gated Recurrent Unit Approach
Reheating furnaces are used to homogeneously reheat the steel stock (Billets, blooms or slabs) at a temperature between 1000°C and 1250°C before hot rolling. Supply of accurate, stable, and reliable control of temperature is most important for reheating furnaces in hot-rolled steel production. The phenomenon of large time lags in temperature is an arduous problem that existed in the combustion system of furnaces, it causes control system big overshoot, continuous oscillation, and may even make the system unstable. In this paper, a prediction model based on gate recurrent unit (GRU) was established to forecast the inside temperature of the furnace by using temperature, fuel, and air time series. Moreover, this paper presents an approach which is combining a prediction model with a feedforward controller that can improve the stability of the temperature control system. Established prediction model of temperatures by collecting data from on-side, and evaluated the model and feedforward performance on the actual reheating furnace. Compared with other dynamic models (recurrent neural network and long short-term memory), the proposed models outperformed by 15.63% and 26.07% on average in terms of the mean absolute error and root mean square error, respectively. Moreover, the proposed control improve traditional PI controller by 33.43% and 19.92% on average in terms of the mean absolute error and root mean square error, respectively. The presented method can be used to reduce the temperature disturbances in the reheating furnaces.
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 33362-33369
Open AccessTemperature Prediction for Reheating Furnace by Gated Recurrent Unit Approach
Reheating furnaces are used to homogeneously reheat the steel stock (Billets, blooms or slabs) at a temperature between 1000°C and 1250°C before hot rolling. Supply of accurate, stable, and reliable control of temperature is most important for reheating furnaces in hot-rolled steel production. The phenomenon of large time lags in temperature is an arduous problem that existed in the combustion system of furnaces, it causes control system big overshoot, continuous oscillation, and may even make the system unstable. In this paper, a prediction model based on gate recurrent unit (GRU) was established to forecast the inside temperature of the furnace by using temperature, fuel, and air time series. Moreover, this paper presents an approach which is combining a prediction model with a feedforward controller that can improve the stability of the temperature control system. Established prediction model of temperatures by collecting data from on-side, and evaluated the model and feedforward performance on the actual reheating furnace. Compared with other dynamic models (recurrent neural network and long short-term memory), the proposed models outperformed by 15.63% and 26.07% on average in terms of the mean absolute error and root mean square error, respectively. Moreover, the proposed control improve traditional PI controller by 33.43% and 19.92% on average in terms of the mean absolute error and root mean square error, respectively. The presented method can be used to reduce the temperature disturbances in the reheating furnaces.