Eman M. Moaaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eman M. Moaaz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ahmed S. Fayed
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
7 shared publicationsEzzat M. Abdel-Moety
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
5 shared publicationsMamdouh R. Rezk
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
5 shared publicationsAhmed S Fayed
Cairo University, Faculty of Pharmacy, Analytical Chemistry Department, Kasr El-Aini Street, ET-11562 Cairo, Egypt
2 shared publications- Amr Mohamed Mahmoud
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo 11562, Egypt
2 shared publications Ezzat M Abdel-Moety
Cairo University, Faculty of Pharmacy, Analytical Chemistry Department, Kasr El-Aini Street, ET-11562 Cairo, Egypt
2 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (10) , 238
A Sustainable Fe-MOF@N-Doped Graphite Electrochemical Platform for Sensitive Dothiepin Determination in Human Plasma
Accurate monitoring of antidepressant drugs is essential for ensuring therapeutic efficacy and minimizing adverse effects, creating a demand for sensitive and reliable analytical methodologies. In the present study, a novel electrochemical sensor was developed for the determination of dothiepin hydrochloride (DOTH) using an iron-based metal–organic framework supported on nitrogen-doped graphite (Fe-MOF@N-dG). The composite material was synthesized through a rapid sonication-assisted approach at ambient temperature, avoiding hydrothermal/solvothermal heating and reducing the consumption of hazardous organic solvents. The physicochemical and electrochemical characteristics of the prepared Fe-MOF@N-dG were investigated using scanning electron microscopy, energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and electrochemical impedance spectroscopy. Characterization results confirmed the successful formation of the composite and demonstrated a synergistic interaction between the Fe-MOF and nitrogen-doped graphite. The conductive N-dG network facilitated electron transfer, while the Fe-MOF provided abundant electrocatalytic active sites, which enhanced sensing performance. Electrochemical measurements were performed in Britton–Robinson buffer solution at pH 3.0 under optimized conditions. The fabricated sensor exhibited a linear response over the concentration range of 0.6–100 μM, with a detection limit of 0.073 μM, indicating good sensitivity toward DOTH determination. The proposed method was validated with respect to accuracy and precision and successfully applied to the analysis of spiked human plasma samples. The environmental sustainability of the developed methodology was also assessed using the recently introduced Environmental, Performance, and Practicality Index (EPPI), together with other established green analytical evaluation tools. The findings demonstrate that the Fe-MOF@N-dG platform offers a potentially sensitive, reliable, and environmentally sustainable strategy for electrochemical determination of DOTH in human plasma.
- 20 October 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (10) , 238
Open AccessA Sustainable Fe-MOF@N-Doped Graphite Electrochemical Platform for Sensitive Dothiepin Determination in Human Plasma
Accurate monitoring of antidepressant drugs is essential for ensuring therapeutic efficacy and minimizing adverse effects, creating a demand for sensitive and reliable analytical methodologies. In the present study, a novel electrochemical sensor was developed for the determination of dothiepin hydrochloride (DOTH) using an iron-based metal–organic framework supported on nitrogen-doped graphite (Fe-MOF@N-dG). The composite material was synthesized through a rapid sonication-assisted approach at ambient temperature, avoiding hydrothermal/solvothermal heating and reducing the consumption of hazardous organic solvents. The physicochemical and electrochemical characteristics of the prepared Fe-MOF@N-dG were investigated using scanning electron microscopy, energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and electrochemical impedance spectroscopy. Characterization results confirmed the successful formation of the composite and demonstrated a synergistic interaction between the Fe-MOF and nitrogen-doped graphite. The conductive N-dG network facilitated electron transfer, while the Fe-MOF provided abundant electrocatalytic active sites, which enhanced sensing performance. Electrochemical measurements were performed in Britton–Robinson buffer solution at pH 3.0 under optimized conditions. The fabricated sensor exhibited a linear response over the concentration range of 0.6–100 μM, with a detection limit of 0.073 μM, indicating good sensitivity toward DOTH determination. The proposed method was validated with respect to accuracy and precision and successfully applied to the analysis of spiked human plasma samples. The environmental sustainability of the developed methodology was also assessed using the recently introduced Environmental, Performance, and Practicality Index (EPPI), together with other established green analytical evaluation tools. The findings demonstrate that the Fe-MOF@N-dG platform offers a potentially sensitive, reliable, and environmentally sustainable strategy for electrochemical determination of DOTH in human plasma.
- Open Access
- 22 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Graphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
This study presents the first application of a graphene/cobalt hexacyanoferrate composite as an ion-to-electron transducer interlayer for the selective electrochemical determination of bupropion. The composite was prepared by homogeneously dispersing graphene with tween 80 and then decorating it with cobalt-hexacyanoferrate nanoparticles. Modifying glassy carbon electrodes with this interlayer improved and stabilized the measured potential by preventing the formation of an aqueous layer beneath the sensing membrane and enhancing charge transfer. The formation of the aqueous layer is a phenomenon commonly associated with solid-contact ion-selective electrodes. These electrodes encounter challenges regarding selectivity affecting their analytical performance in the presence of ions with similar charges and proper lipophilicity. Molecularly imprinted polymer (MIP) approach was employed to resolve the selectivity problem of analyzing bupropion in presence of naltrexone for obesity management. Scanning electron microscope and Fourier-transform infrared were utilized to characterize the fabricated composite and the MIP. Two cationic exchangers were separately integrated with the precipitated MIP to produce sensors for selective determination of bupropion in the dosage form and in spiked human plasma. The sensors exhibited Nernstian slope of 54.66 mV/decade and 55.89 mV/decade with detection limits as low as 2.51 × 10− 7 M and 2.0 × 10− 7 M. Moreover, three different metric ways verified sufficient sustainability of the proposed potentiometric method.
- 22 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessGraphene-cobalt hexacyanoferrate modified sensor doped with molecularly imprinted polymer for selective potentiometric determination of bupropion
This study presents the first application of a graphene/cobalt hexacyanoferrate composite as an ion-to-electron transducer interlayer for the selective electrochemical determination of bupropion. The composite was prepared by homogeneously dispersing graphene with tween 80 and then decorating it with cobalt-hexacyanoferrate nanoparticles. Modifying glassy carbon electrodes with this interlayer improved and stabilized the measured potential by preventing the formation of an aqueous layer beneath the sensing membrane and enhancing charge transfer. The formation of the aqueous layer is a phenomenon commonly associated with solid-contact ion-selective electrodes. These electrodes encounter challenges regarding selectivity affecting their analytical performance in the presence of ions with similar charges and proper lipophilicity. Molecularly imprinted polymer (MIP) approach was employed to resolve the selectivity problem of analyzing bupropion in presence of naltrexone for obesity management. Scanning electron microscope and Fourier-transform infrared were utilized to characterize the fabricated composite and the MIP. Two cationic exchangers were separately integrated with the precipitated MIP to produce sensors for selective determination of bupropion in the dosage form and in spiked human plasma. The sensors exhibited Nernstian slope of 54.66 mV/decade and 55.89 mV/decade with detection limits as low as 2.51 × 10− 7 M and 2.0 × 10− 7 M. Moreover, three different metric ways verified sufficient sustainability of the proposed potentiometric method.
- Open Access
- 29 May 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (23) , 18475-18489
Innovative sensors with selectivity enhancement by molecularly imprinted polymers for the concurrent quantification of donepezil and memantine
This work is overcoming the selectivity issue using the molecularly imprinted polymer (MIP) approach to determine donepezil (DON) and memantine (MEM) in their combined pharmaceutical formulation.
- 29 May 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (23) , 18475-18489
Open AccessInnovative sensors with selectivity enhancement by molecularly imprinted polymers for the concurrent quantification of donepezil and memantine
This work is overcoming the selectivity issue using the molecularly imprinted polymer (MIP) approach to determine donepezil (DON) and memantine (MEM) in their combined pharmaceutical formulation.
- 1 February 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (2) , 027502
Molecularly-Imprinted Polymer-Based Electrochemical Sensor for Indirect Determination of Memantine: Greenness and Whiteness Assessment
Substantial preference for target analytes was attained by molecularly-imprinted polymers (MIPs). A novel indirect voltammetric technique was developed to provide a useful gate for the analysis of electro-inactive substances through selective interaction with MIP and hence decrease of redox-active probe signal at the electrode’s surface. In this work, a methyldopa-based MIP was fabricated for the selective binding with memantine (MEM), a voltammetry-inactive and widely used drug for Alzheimer’s disease. In-situ electropolymerization of methyldopa monomer was implemented onto a pencil graphite electrode using MEM as a template in phosphate buffer pH 7.0. The monomer-template interaction was evaluated by UV-spectroscopy. The modified surface of the electrode was characterized using scanning electron microscope and X-ray photoelectron spectroscopy. The functionality of the sensor was assessed using cyclic voltammetry and electrochemical impedance analysis. The response was linear over a concentration range of 1.0 × 10–12 to 1.0 × 10−10 M with a detection limit down to 1.5 × 10−13 M. Sensor selectivity was studied using the co-formulated drug, donepezil. The MIP-sensor exhibited high sensitivity and proper selectivity, allowing its applicability for the analysis of MEM in combined formulations and in spiked human plasma samples. The overall process was subjected to a greenness and whiteness assessment, confirming its eco-friendliness and sustainability.
- 1 February 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (2) , 027502
Molecularly-Imprinted Polymer-Based Electrochemical Sensor for Indirect Determination of Memantine: Greenness and Whiteness Assessment
Substantial preference for target analytes was attained by molecularly-imprinted polymers (MIPs). A novel indirect voltammetric technique was developed to provide a useful gate for the analysis of electro-inactive substances through selective interaction with MIP and hence decrease of redox-active probe signal at the electrode’s surface. In this work, a methyldopa-based MIP was fabricated for the selective binding with memantine (MEM), a voltammetry-inactive and widely used drug for Alzheimer’s disease. In-situ electropolymerization of methyldopa monomer was implemented onto a pencil graphite electrode using MEM as a template in phosphate buffer pH 7.0. The monomer-template interaction was evaluated by UV-spectroscopy. The modified surface of the electrode was characterized using scanning electron microscope and X-ray photoelectron spectroscopy. The functionality of the sensor was assessed using cyclic voltammetry and electrochemical impedance analysis. The response was linear over a concentration range of 1.0 × 10–12 to 1.0 × 10−10 M with a detection limit down to 1.5 × 10−13 M. Sensor selectivity was studied using the co-formulated drug, donepezil. The MIP-sensor exhibited high sensitivity and proper selectivity, allowing its applicability for the analysis of MEM in combined formulations and in spiked human plasma samples. The overall process was subjected to a greenness and whiteness assessment, confirming its eco-friendliness and sustainability.
- Open Access
- 23 September 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-10
An eco-friendly smartphone based HPTLC method versus conventional densitometric one for determination of Naltrexone and Bupropion
The rapid uprising technologies of smartphone applications and software introduced a new era for analytical detection techniques. It has transformed bench-top laboratory methods into simpler ones depending on cost-effective, portable, and widely accessible devices. In this work, two high performance thin layer chromatographic (HPTLC) methods were developed based on smartphone’s camera detection and either ImageJ desktop software or Color-Picker smartphone’s application as alternative techniques to conventional densitometric detection. A mixture of Naltrexone hydrochloride (NAL) and Bupropion hydrochloride (BUP) was chromatographed on HPTLC- plates using ethyl acetate, methanol, acetone, and glacial acetic acid (3:6:1:0.5, by volume) as a developing system. The developed plates were scanned at 203 nm for the densitometric analysis, then visualized by modified Dragendorff’s reagent and shot by a smartphone’s camera. The captured images were uploaded to either ImageJ software or Color-Picker application to detect the separated spots. The results derived from the three detection methods were compared over the concentration range of 0.4–24 & 0.6–18 µg/band for the densitometric method, 0.4–24 & 2–24 µg/band for ImageJ built method and 0.8–20 & 5–20 µg/band for Color Picker built method for NAL and BUP, respectively. The methods were found to be appropriate for assaying both active drug substances in pure forms and combined in marketed pharmaceutical formulations. The excellent sustainability of densitometric and ImageJ-based methods enabled also the assessment of their dosage form content uniformity. The greenness and sustainability of the methods were assessed by three metric tools, namely Green Analytical Procedure Index (GAPI), Analytical GREEnness Metric Approach (AGREE), and White Analytical Chemistry (WAC). The assessments results confirmed the sustainability and superiority of the proposed methods in terms of sample treatment, waste mount, energy consumption, cost, and number of analyzed samples per an hour.
- 23 September 2024
- Published by Springer Nature in BMC Chemistry
- Vol. 18 (1) , 1-10
Open AccessAn eco-friendly smartphone based HPTLC method versus conventional densitometric one for determination of Naltrexone and Bupropion
The rapid uprising technologies of smartphone applications and software introduced a new era for analytical detection techniques. It has transformed bench-top laboratory methods into simpler ones depending on cost-effective, portable, and widely accessible devices. In this work, two high performance thin layer chromatographic (HPTLC) methods were developed based on smartphone’s camera detection and either ImageJ desktop software or Color-Picker smartphone’s application as alternative techniques to conventional densitometric detection. A mixture of Naltrexone hydrochloride (NAL) and Bupropion hydrochloride (BUP) was chromatographed on HPTLC- plates using ethyl acetate, methanol, acetone, and glacial acetic acid (3:6:1:0.5, by volume) as a developing system. The developed plates were scanned at 203 nm for the densitometric analysis, then visualized by modified Dragendorff’s reagent and shot by a smartphone’s camera. The captured images were uploaded to either ImageJ software or Color-Picker application to detect the separated spots. The results derived from the three detection methods were compared over the concentration range of 0.4–24 & 0.6–18 µg/band for the densitometric method, 0.4–24 & 2–24 µg/band for ImageJ built method and 0.8–20 & 5–20 µg/band for Color Picker built method for NAL and BUP, respectively. The methods were found to be appropriate for assaying both active drug substances in pure forms and combined in marketed pharmaceutical formulations. The excellent sustainability of densitometric and ImageJ-based methods enabled also the assessment of their dosage form content uniformity. The greenness and sustainability of the methods were assessed by three metric tools, namely Green Analytical Procedure Index (GAPI), Analytical GREEnness Metric Approach (AGREE), and White Analytical Chemistry (WAC). The assessments results confirmed the sustainability and superiority of the proposed methods in terms of sample treatment, waste mount, energy consumption, cost, and number of analyzed samples per an hour.
- 17 May 2022
- Published by Wiley in Electroanalysis
- Vol. 35 (1)
Microfabricated Solid‐contact Potentiometric Sensor for Determination of Tedizolid Phosphate, Application to Content Uniformity Testing
Solid contact sensors were designed for determination of the antibiotic prodrug tedizolid phosphate. The sensors are based on; microfabricated copper as cost‐effective electrode substrate and graphene layer as a transducer. The ion sensing PVC polymeric membrane was optimized by proper selection of the anion exchanger. The graphene layer was characterized by scanning electron microscopy, Raman spectroscopy, FT‐IR, besides measuring electrochemical impedance for the fabricated sensors. The potential drift decreased down to 0.133 mV h−1 compared to 6.67 mV h−1 for graphene free sensor. The sensors have been used to determine tedizolid phosphate in its pharmaceutical formulation and content uniformity testing applications.
- 17 May 2022
- Published by Wiley in Electroanalysis
- Vol. 35 (1)
Microfabricated Solid‐contact Potentiometric Sensor for Determination of Tedizolid Phosphate, Application to Content Uniformity Testing
Solid contact sensors were designed for determination of the antibiotic prodrug tedizolid phosphate. The sensors are based on; microfabricated copper as cost‐effective electrode substrate and graphene layer as a transducer. The ion sensing PVC polymeric membrane was optimized by proper selection of the anion exchanger. The graphene layer was characterized by scanning electron microscopy, Raman spectroscopy, FT‐IR, besides measuring electrochemical impedance for the fabricated sensors. The potential drift decreased down to 0.133 mV h−1 compared to 6.67 mV h−1 for graphene free sensor. The sensors have been used to determine tedizolid phosphate in its pharmaceutical formulation and content uniformity testing applications.
- 28 June 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (6) , 1485-1491
Eco-Friendly Chromatographic Methods for Determination of Acemetacin and Indomethacin; Greenness Profile Assessment
Background: The green chemistry approach was developed for the purpose of saving the environment by using green solvents. Applying green analytical chemistry principles to traditional methods is considered a challenge. Acemetacin is a commonly used analgesic prodrug that bioactivates to indomethacin. Objective: Developing two simple, eco-friendly chromatographic methods for simultaneous determination of acemetacin and indomethacin. Method: The first method is HPLC-DAD. Separation was performed on a Waters XBridge® Shield RP18 (250 × 4.6 mm, 5 µm) analytical column with ethanol–ammonium acetate buffer (50 mM, pH 3.5 ± 0.1; 60:40, v/v) as a mobile phase at a flow rate of 1 mL/min at 25 ± 0.5°C and UV detection at 254 nm. The other method is TLC coupled with densitometric quantification using pre-coated silica TLC plates and butanol–ethyl acetate (70:30, v/v) elution system. The plates were scanned at 254 nm. Results: Both methods were validated according to International Conference on Harmonization guidelines. Linearity was confirmed for both over a concentration range of 1–100 µg/mL for the HPLC method and 0.2–7 µg/band for TLC-densitometric method. The methods’ greenness was evaluated by the National Environmental Methods Index, Eco-Scale, Green Analytical Procedure Index metrics and Analytical GREEnness Metric Approach. Conclusions: The proposed methods were found to be suitable for determination of studied drugs in their marketed formulations and is suggested for routine analysis in quality control laboratories. Highlights: The developed HPLC method shortened the elution time of the analyzed drugs saving more time and money and the TLC method lowered the drugs’ detection limit. HPLC and TLC methods were validated for the assay of acemetacin and indomethacin. The methods’ greenness was evaluated and compared to published methods. The developed HPLC method shortened the elution time of the analyzed drugs, saving time and money and the TLC method lowered the drugs’ detection limit.
- 28 June 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (6) , 1485-1491
Eco-Friendly Chromatographic Methods for Determination of Acemetacin and Indomethacin; Greenness Profile Assessment
Background: The green chemistry approach was developed for the purpose of saving the environment by using green solvents. Applying green analytical chemistry principles to traditional methods is considered a challenge. Acemetacin is a commonly used analgesic prodrug that bioactivates to indomethacin. Objective: Developing two simple, eco-friendly chromatographic methods for simultaneous determination of acemetacin and indomethacin. Method: The first method is HPLC-DAD. Separation was performed on a Waters XBridge® Shield RP18 (250 × 4.6 mm, 5 µm) analytical column with ethanol–ammonium acetate buffer (50 mM, pH 3.5 ± 0.1; 60:40, v/v) as a mobile phase at a flow rate of 1 mL/min at 25 ± 0.5°C and UV detection at 254 nm. The other method is TLC coupled with densitometric quantification using pre-coated silica TLC plates and butanol–ethyl acetate (70:30, v/v) elution system. The plates were scanned at 254 nm. Results: Both methods were validated according to International Conference on Harmonization guidelines. Linearity was confirmed for both over a concentration range of 1–100 µg/mL for the HPLC method and 0.2–7 µg/band for TLC-densitometric method. The methods’ greenness was evaluated by the National Environmental Methods Index, Eco-Scale, Green Analytical Procedure Index metrics and Analytical GREEnness Metric Approach. Conclusions: The proposed methods were found to be suitable for determination of studied drugs in their marketed formulations and is suggested for routine analysis in quality control laboratories. Highlights: The developed HPLC method shortened the elution time of the analyzed drugs saving more time and money and the TLC method lowered the drugs’ detection limit. HPLC and TLC methods were validated for the assay of acemetacin and indomethacin. The methods’ greenness was evaluated and compared to published methods. The developed HPLC method shortened the elution time of the analyzed drugs, saving time and money and the TLC method lowered the drugs’ detection limit.
- 9 May 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (8) , 1895-1901
Determination of Tedizolid Phosphate Using Graphene Nanocomposite Based Solid Contact Ion Selective Electrode; Green Profile Assessment by Eco‐scale and GAPI Approach
Antibiotics determination plays a major role in minimizing antimicrobial resistance starting from quality control of pharmaceutical formulations to therapeutic drug monitoring. Green modified glassy carbon electrode has been developed for determination of tedizolid phosphate; new antibiotic prodrug; in presence of its active metabolite. The graphene transducer interlayer, dispersed with PVC, improved the electrode stability and standard potential reproducibility. Graphene hydrophobicity prevented the water layer formation between the sensing layers that decreased the potential drift down to 267 μV h−1. Electrochemical impedance showed a low resistance value for graphene containing sensor due to its high electron transfer ability.
- 9 May 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (8) , 1895-1901
Determination of Tedizolid Phosphate Using Graphene Nanocomposite Based Solid Contact Ion Selective Electrode; Green Profile Assessment by Eco‐scale and GAPI Approach
Antibiotics determination plays a major role in minimizing antimicrobial resistance starting from quality control of pharmaceutical formulations to therapeutic drug monitoring. Green modified glassy carbon electrode has been developed for determination of tedizolid phosphate; new antibiotic prodrug; in presence of its active metabolite. The graphene transducer interlayer, dispersed with PVC, improved the electrode stability and standard potential reproducibility. Graphene hydrophobicity prevented the water layer formation between the sensing layers that decreased the potential drift down to 267 μV h−1. Electrochemical impedance showed a low resistance value for graphene containing sensor due to its high electron transfer ability.
- 21 April 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 60 (1) , 51-60
Stability-Indicating Determination of Tedizolid Phosphate in the Presence of its Active Form and Possible Degradants
Tedizolid phosphate is an antibiotic prodrug that is metabolized into tedizolid which is used against various resistant bacterial strains. In this study, tedizolid phosphate was subjected to stress degradation conditions, namely, hydrolysis (neutral, acidic and alkaline), thermal, oxidative and photolytic ones. The prodrug was stable toward thermal and photolytic stress conditions, while it showed significant degradation upon applying oxidative and hydrolytic conditions. Two suggested chromatographic methods are described for separation and determination of tedizolid phosphate from the resulted degradation products. The first method is HPLC using Waters Xselect HSS C18 (250 × 4.6 mm, 5 μm) analytical column and mobile phase composed of phosphate buffer (50 mM, pH 6.5):acetonitrile (70:30, %v/v) pumped at flow rate of 1.0 mL/min with UV-detection at 300 nm. The second method is a TLC coupled with densitometric quantitation, precoated silica TLC-plates as a stationary phase and a mobile phase of methanol:butanol:ethyl acetate:ammonia (33%, w/v) (60:20:20:10,%v/v) were used. The chromatographed plates were scanned at 300 nm. The linearity was confirmed over concentration range of 1–100 μg/mL and 1–12 μg/band for HPLC and TLC-densitometric methods, respectively. Both methods were found to be suitable for determination of tedizolid phosphate in pure form and in its pharmaceutical formulations.
- 21 April 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 60 (1) , 51-60
Stability-Indicating Determination of Tedizolid Phosphate in the Presence of its Active Form and Possible Degradants
Tedizolid phosphate is an antibiotic prodrug that is metabolized into tedizolid which is used against various resistant bacterial strains. In this study, tedizolid phosphate was subjected to stress degradation conditions, namely, hydrolysis (neutral, acidic and alkaline), thermal, oxidative and photolytic ones. The prodrug was stable toward thermal and photolytic stress conditions, while it showed significant degradation upon applying oxidative and hydrolytic conditions. Two suggested chromatographic methods are described for separation and determination of tedizolid phosphate from the resulted degradation products. The first method is HPLC using Waters Xselect HSS C18 (250 × 4.6 mm, 5 μm) analytical column and mobile phase composed of phosphate buffer (50 mM, pH 6.5):acetonitrile (70:30, %v/v) pumped at flow rate of 1.0 mL/min with UV-detection at 300 nm. The second method is a TLC coupled with densitometric quantitation, precoated silica TLC-plates as a stationary phase and a mobile phase of methanol:butanol:ethyl acetate:ammonia (33%, w/v) (60:20:20:10,%v/v) were used. The chromatographed plates were scanned at 300 nm. The linearity was confirmed over concentration range of 1–100 μg/mL and 1–12 μg/band for HPLC and TLC-densitometric methods, respectively. Both methods were found to be suitable for determination of tedizolid phosphate in pure form and in its pharmaceutical formulations.