JMJun Mutaguchi

Jun Mutaguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jun Mutaguchi has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Recurrent Severe Drug‐Induced Aseptic Meningitis due to Trimethoprim–Sulfamethoxazole Mimicking Ventriculitis‐Like MRI Findings in a Patient Receiving Anti–PD‐1 Therapy

    by Makoto Yazaki, Masaoki Hidaka, Satomi Mezuki, Takuya Kiyohara, Yuji Shono, Kuniyuki Nakamura, Yoshinobu Wakisaka, Koji Yamashita, Shunsuke Goto, Jun Mutaguchi, et al.

    Drug‐induced aseptic meningitis is a rare and usually self‐limiting condition. Although clinical and cerebrospinal fluid findings may resemble those of bacterial meningitis, brain magnetic resonance imaging findings are typically normal. An 80‐year‐old woman receiving anti–PD‐1 antibody therapy for bladder cancer developed severe meningitis with high fever and disturbed consciousness. Brain magnetic resonance imaging revealed findings suggestive of ventriculitis, strongly suggesting bacterial meningitis; however, blood and cerebrospinal fluid cultures obtained before the initiation of antibiotic therapy were negative. Two months earlier, the patient had experienced a similar episode of severe meningitis of unknown etiology. Careful review of the clinical course revealed that trimethoprim‐sulfamethoxazole had been administered shortly before the onset of both episodes. The patient was diagnosed with recurrent drug‐induced aseptic meningitis caused by trimethoprim‐sulfamethoxazole. Patients with drug‐induced aseptic meningitis rarely present with severe clinical and radiological features mimicking bacterial meningitis. Therefore, it should be considered in patients with culture‐negative meningitis, particularly those receiving immune checkpoint inhibitors.

  • Open Access

    A Case of Cerebral Air Embolization During Robot‐Assisted Partial Nephrectomy via a Retroperitoneal Approach for the Patient With Renal Cell Carcinoma

    by Takashi Matsumoto, Masashi Kaitsumaru, Keiji Tsukino, Jun Mutaguchi, Shigehiro Tsukahara, Tokiyoshi Tanegashima, Shunsuke Goto, Satoshi Kobayashi, Masaki Shiota, Masatoshi Eto, et al.

    Introduction: Cerebral air embolism accompanied by right‐to‐left shunt through the venous system during Robot‐assisted partial nephrectomy (RAPN) is regarded as a rare occurrence, with a high mortality rate. Case Presentation: A case of a 77‐year‐old man with renal cell carcinoma who developed cerebral air embolism during right retroperitoneal RAPN using AirSeal. Intraoperatively, a sudden drop in end‐tidal CO 2 was observed during tumor resection. Postoperatively, the patient developed seizures, and imaging revealed cerebral air embolization. Despite hyperbaric oxygen therapy and intensive care, he progressed to fatal cerebral infarction. Conclusion: This case highlights the risk of serious brain stroke during RAPN. The pathways of air entry into the cerebral circulation occasionally remain unclear and are difficult to fully exclude preoperatively. Renal vein clamping and adequate insufflation pressure are recommended when the tumor is entirely endophytic or close to the renal vein, especially when performing a right retroperitoneal approach.

  • Open Access

    AI System for Detecting Flat Bladder Tumours in Cystoscopic Images

    by Jun Mutaguchi, Masahiro Oda, Tokiyoshi Tanegashima, Shigehiro Tsukahara, Shunsuke Goto, Satoshi Kobayashi, Takashi Matsumoto, Masaki Shiota, Kensaku Mori, Masatoshi Eto

    Bladder tumours have a high intravesical recurrence rate after transurethral resection of the bladder tumour (TURBT). Overlooking tumours...

  • Open Access

    Feasibility of a new L43K ultrasound probe attachment for intraoperative laparoscopic ultrasonography in robot-assisted partial nephrectomy

    by Satoshi Kobayashi, Ryu Nakadate, Shinichi Miyata, Keiji Tsukino, Jun Mutaguchi, Shohei Ueda, Takashi Matsumoto, Keisuke Monji, Masaki Shiota, Junichi Inokuchi, et al.

    Background: We assessed the feasibility of a new probe attachment (PA) developed to improve the ease of holding the drop-in-type L43K ultrasound probe during robot-assisted partial nephrectomy. Materials and methods: We retrospectively analyzed the outcomes of 58 patients after robot-assisted partial nephrectomy using the conventional grip and 13 patients after surgery using the PA between September 2019 and February 2021. Propensity score matching (1:1) was performed to adjust for potential baseline confounders. The usability of the PA was evaluated regarding (1) total procedure time for intraoperative laparoscopic ultrasound; (2) proportion rate of intraoperative laparoscopic ultrasound in console time; (3) total number of probe fin grips; (4) total number of grip failures; (5) intraoperative laparoscopic ultrasound procedure time per grip; and (6) rate of successful gripping. Results: After matching, 12 patients were allocated to each group, and the tumor site was significantly different between the groups. Usability was significantly better in the PA group: (1) conventional versus PA: 6.8 versus 7.6, p = 0.53; (2) 5.6% versus 6.1%, p = 0.61; (3) 8 versus 10, p = 0.32; (4) 3 versus 0, p = 0.014; and (5) 1.5% versus 0.7%, p = 0.021; (6) 66% versus 100%, p = 0.002. In patients with complex renal tumors, completely endophytic tumors, and renal hilum tumors, nearly identical improvements in usability were observed: (1) 9.8 versus 7.8 min, p = 0.21; (2) 9.9% versus 4.7%, p = 0.001; (3) 7 versus 6, p = 0.025; (4) 3 versus 0, p = 0.048, (5) 2.9 versus 1.6 min, p = 0.89, and (6) 60% versus 100%, p = 0.003. Conclusions: Our proposed L43K PA can enhance the usability of the probe for intraoperative laparoscopic ultrasonography during robot-assisted partial nephrectomy and increase the accuracy of ultrasonography for complex renal tumors.

  • Functional outcomes in robot-assisted partial nephrectomy with three-dimensional images reconstructed from computed tomography: a propensity score-matched comparative analysis

    by Satoshi Kobayashi, Keiji Tsukino, Jun Mutaguchi, Tokiyoshi Tanegashi, Shunsuke Goto, Takashi Matsumoto, Masaki Shiota, Masatoshi Eto

    Our objective was to investigate the long-term functional outcomes of robot-assisted partial nephrectomy (RAPN) combined with three-dimensional (3D) imaging. The 3D images, reconstructed using computed tomography, were introduced in RAPN procedures. The demographic, oncological, functional, and volumetric outcomes of 296 patients who underwent RAPN with and without 3D imaging between 2013 and 2021 were analyzed retrospectively. Propensity score matching (1:1) was performed to adjust for potential baseline confounders. After matching, 71 patients were allocated to each group. In the 3D RAPN (3DRPN) group, functional outcomes significantly improved: the number of patients with over 90% estimated glomerular filtration rate (eGFR) preservation rate (40 vs. 43, P = 0.044), eGFR preservation rate (88.0% vs. 91.6%, P = 0.006), the number of patients with chronic kidney disease (CKD) upstaging (26 vs. 13, P = 0.023), and split renal function preservation rate (operated kidney: 84.9% vs. 88.5%, P = 0.015). The 3DRPN group showed superiority in terms of >90% eGFR preservation (P = 0.010), CKD upstaging-free survival rates (P < 0.001), and volumetric outcomes (excess parenchymal volume: 27.9 vs. 17.7 mL, P = 0.030; parenchyma volume preservation rate: 81.6% vs. 88.8%, P = 0.006). Three-dimensional imaging was positively associated with eGFR preservation (P = 0.023, odds ratio: 2.34) and prevention of CKD upstaging (P = 0.013, odds ratio: 2.90). In this study, RAPN combined with 3D imaging underscored the preservation of eGFR > 90% and the prevention of CKD upstaging by improving the preservation rate of renal parenchyma and split renal function.


  • Validation of schedules for optimal prostate‐specific antigen monitoring after radical prostatectomy

    by Leandro Blas, Masaki Shiota, Tokiyoshi Tanegashima, Shigehiro Tsukahara, Shohei Ueda, Jun Mutaguchi, Shunsuke Goto, Satoshi Kobayashi, Takashi Matsumoto, Junichi Inokuchi, et al.

    Background: Early detection of biochemical recurrence (BCR) after radical prostatectomy (RP) is crucial for early treatment and improving survival outcomes. The optimal prostate‐specific antigen (PSA) monitoring remains unclear, and several models have been proposed. We aimed to externally validate four models for optimal PSA monitoring after RP and propose modifications to improve them.Methods: We reviewed the clinicopathological data of 896 patients who underwent robot‐assisted RP between 2009 and 2022. We examined all PSA values and estimated the PSA value for four monitoring schedules at each time point in the virtual follow‐up. We defined the ideal PSA for BCR detection between 0.2 and 0.4 ng/mL.Results: During the median follow‐up of 21.4 months, 128 (14.3%) patients presented BCR. The original and modified Keio models, National Cancer Center Hospital model, and American Urological Association/American Society for Radiation Oncology model detected BCR in 14 (10.9%), three (2.3%), 12 (9.4%), and 11 (8.6%) patients with PSA >0.4 ng/mL. Most patients experienced BCR detected with PSA >0.4 ng/mL during the first year postoperative. The modification of interval within 6 months postoperative avoided BCR detection with PSA >0.4 ng/mL within the first year postoperative in 8/9 (88.9%), 1/2 (50.0%), 5/6 (83.3%), and 4/4 (100%) for the original and modified Keio models, National Cancer Center Hospital model, and American Urological Association/American Society for Radiation Oncology model, respectively.Conclusion: We validated four models for PSA monitoring after RP to detect BCR and suggested modifications to avoid detections out of the desired range of PSA. These modifications could help to establish an optimal PSA monitoring schedule after RP.


  • Artificial Intelligence for Segmentation of Bladder Tumor Cystoscopic Images Performed by U-Net with Dilated Convolution

    by Jun Mutaguchi, Ken'IChi Morooka, Satoshi Kobayashi, Aiko Umehara, Shoko Miyauchi, Fumio Kinoshita, Junichi Inokuchi, Yoshinao Oda, Ryo Kurazume, Masatoshi Eto

    Background: Early intravesical recurrence after transurethral resection of bladder tumors (TURBT) is often caused by overlooking of tumors during TURBT. Although narrow-band imaging and photodynamic diagnosis were developed to detect more tumors than conventional white-light imaging, the accuracy of these systems has been subjective, along with poor reproducibility due to their dependence on the physician's experience and skills. To create an objective and reproducible diagnosing system, we aimed at assessing the utility of artificial intelligence (AI) with Dilated U-Net to reduce the risk of overlooked bladder tumors when compared with the conventional AI system, termed U-Net. Materials and Methods: We retrospectively obtained cystoscopic images by converting videos obtained from 120 patients who underwent TURBT into 1790 cystoscopic images. The Dilated U-Net, which is an extension of the conventional U-Net, analyzed these image datasets. The diagnostic accuracy of the Dilated U-Net and conventional U-Net were compared by using the following four measurements: pixel-wise sensitivity (PWSe); pixel-wise specificity (PWSp); pixel-wise positive predictive value (PWPPV), representing the AI diagnostic accuracy per pixel; and dice similarity coefficient (DSC), representing the overlap area between the bladder tumors in the ground truth images and segmentation maps. Results: The cystoscopic images were divided as follows, according to the pathological T-stage: 944, Ta; 412, T1; 329, T2; and 116, carcinoma in situ . The PWSe, PWSp, PWPPV, and DSC of the Dilated U-Net were 84.9%, 88.5%, 86.7%, and 83.0%, respectively, which had improved when compared to that with the conventional U-Net by 1.7%, 1.3%, 2.1%, and 2.3%, respectively. The DSC values were high for elevated lesions and low for flat lesions for both Dilated and conventional U-Net. Conclusions: Dilated U-Net, with higher DSC values than conventional U-Net, might reduce the risk of overlooking bladder tumors during cystoscopy and TURBT.


  • Deep learning system for automatic detection of bladder tumors in cystoscopic images

    by J. Mutaguchi, M. Oda, S. Ueda, F. Kinoshita, H. Naganuma, T. Matsumoto, K. Lee, K. Monji, K. Kashiwagi, A. Takeuchi, et al.