Lakshmikanthan Chitra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lakshmikanthan Chitra has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- K. S. Kavitha Kumari
Aarupadai Veedu Institute of Technology, Vinayaka Mission’s Research Foundation
3 shared publications - Kannan Boopathy
Aarupadai Veedu Institute of Technology, Vinayaka Mission’s Research Foundation
2 shared publications - P. Poornima
Aarupadai Veedu Institute of Technology, Vinayaka Mission’s Research Foundation
2 shared publications - Rattan Kumar Venkatesan
Vinayaka Mission’s Chennai Campus
2 shared publications V. Ramakrishnan
2 shared publicationsA. Preethi
Department of EEE, Aarupadai Veedu Institute of Technology, Chennai-600069, Tamilnadu, India
1 shared publication
Latest Publications
- 1 May 2026
- Published by Springer Nature
- p. 171-185
Development of Multi Level Transformerless Inverter for Grid Integration of Solar Photovoltaic Power Plant
- 1 May 2026
- Published by Springer Nature
- p. 171-185
Development of Multi Level Transformerless Inverter for Grid Integration of Solar Photovoltaic Power Plant
- 15 October 2025
- Published by Springer Nature
- p. 425-434
Design and Analysis of a Single-Phase 29-Level Switched-Capacitor Boost Multilevel Inverter
- 15 October 2025
- Published by Springer Nature
- p. 425-434
Design and Analysis of a Single-Phase 29-Level Switched-Capacitor Boost Multilevel Inverter
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2357-2366
Five-level transformerless inverter with reduced voltage stress on components
Leakage current flow is an important issue of transformerless (TL) inverters due to the absence of galvanic isolation between the source and grid sides in grid-connected solar photovoltaic (PV) systems. This article proposes a five-level (5L) TL direct ground point (DGP) type inverter employing two switched capacitors (SCs). The DGP configuration shares a common ground point for the PV negative terminal with grid neutral, thereby completely suppressing the leakage current. The employed semiconductors endure maximum voltage stress equivalent to the input voltage, while the switched capacitors (SCs) are rated at only half of the input voltage. This significantly reduces both the size and cost of the inverter. In addition, it uses reduced power components and has a lower total standing voltage per unit among the recent same art of topologies. A detailed comparison to show the merits of the proposed inverter is presented. Simulations and experiments were conducted at a 1 kW output power level in stand-alone as well as grid-connected mode to validate the feasibility of the proposed inverter.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2357-2366
Open AccessFive-level transformerless inverter with reduced voltage stress on components
Leakage current flow is an important issue of transformerless (TL) inverters due to the absence of galvanic isolation between the source and grid sides in grid-connected solar photovoltaic (PV) systems. This article proposes a five-level (5L) TL direct ground point (DGP) type inverter employing two switched capacitors (SCs). The DGP configuration shares a common ground point for the PV negative terminal with grid neutral, thereby completely suppressing the leakage current. The employed semiconductors endure maximum voltage stress equivalent to the input voltage, while the switched capacitors (SCs) are rated at only half of the input voltage. This significantly reduces both the size and cost of the inverter. In addition, it uses reduced power components and has a lower total standing voltage per unit among the recent same art of topologies. A detailed comparison to show the merits of the proposed inverter is presented. Simulations and experiments were conducted at a 1 kW output power level in stand-alone as well as grid-connected mode to validate the feasibility of the proposed inverter.
- 27 November 2024
- Published by Springer Nature
- p. 287-295
ANN-Based Interleaved Synchronous Rectifier for Electric Vehicle Charging
- 27 November 2024
- Published by Springer Nature
- p. 287-295
ANN-Based Interleaved Synchronous Rectifier for Electric Vehicle Charging
- 6 July 2024
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (17) , 17929-17949
Anomaly detection using deep learning approach for IoT smart city applications
- 6 July 2024
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 84 (17) , 17929-17949
Anomaly detection using deep learning approach for IoT smart city applications
- Open Access
- 1 January 2023
- Published by National Library of Serbia in Thermal Science
- Vol. 27 (6 Part B) , 4851-4860
Performance enhancement of water output via latent heat storage system with single slope solar stills
The purpose of this study was to design, build, and assess the performance of a latent heat storage system (LHSS) in tandem with a single slope solar still (SSSS). Using a solar accumulator to transfer hot water to a shell and a spiral finned tube (SSFT) filled with 30 kg of paraffin wax (PW)-1.2 w % of Al2O3 nanocomposites, latent heat was stored. To test the effect of the storage system's performance, two trials were conducted, with and without storage, under as similar of conditions as could be arranged. The proposed storage system design eliminates any potential issues with usage of PW as the storage system in conjunction with the solar still. An outcome indicated that daily fresh water output was enhanced by 4.63% when the solar still was used in conjunction with the storage system.
- 1 January 2023
- Published by National Library of Serbia in Thermal Science
- Vol. 27 (6 Part B) , 4851-4860
Open AccessPerformance enhancement of water output via latent heat storage system with single slope solar stills
The purpose of this study was to design, build, and assess the performance of a latent heat storage system (LHSS) in tandem with a single slope solar still (SSSS). Using a solar accumulator to transfer hot water to a shell and a spiral finned tube (SSFT) filled with 30 kg of paraffin wax (PW)-1.2 w % of Al2O3 nanocomposites, latent heat was stored. To test the effect of the storage system's performance, two trials were conducted, with and without storage, under as similar of conditions as could be arranged. The proposed storage system design eliminates any potential issues with usage of PW as the storage system in conjunction with the solar still. An outcome indicated that daily fresh water output was enhanced by 4.63% when the solar still was used in conjunction with the storage system.
- 19 May 2022
- Published by Springer Nature
- p. 583-596
Artificial Intelligent Based Control of Improved Converter for Hybrid Renewable Energy Systems
- 19 May 2022
- Published by Springer Nature
- p. 583-596
Artificial Intelligent Based Control of Improved Converter for Hybrid Renewable Energy Systems
- Retracted
- 1 May 2019
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 60 (1_suppl) , 3052-3068
RETRACTED: IOT-based oil condition monitoring of wind turbine gear boxes with smart sensor technology
The performance parameters such as viscosity, humidity and pressure of the gear box lubricating oil should be monitored and controlled to improve the efficiency of the windmill. The recent technique like Internet Of Things is used for the continuous transmission of bulk data of these parameters from one machine to other machine which is situated in remote locations. Also the development of mobile technology and web made the live monitoring easier. Thus, transmission and sharing of data takes place without any time delay. The technology also helps to completely eliminate the assistance nearby the site. The large wind farms in coastal areas are easily and continuously monitored and the data are recorded from remote locations with the mobile technology having internet connections. This paper also reports the novelty in the design of micro electro mechanical systems viscosity sensor, micro electro mechanical system humidity sensor and micro electro mechanical system pressure sensor for continuous monitoring of the lubricating system. The following are the principles used for the sensor design such as thermal actuation for viscosity measurement, cantilever principle for humidity and capacitive type for pressure measurement. The sensitivity of micro electro mechanical system viscosity sensor, micro electro mechanical system humidity sensor and micro electro mechanical system pressure sensor are 0.5–0.75 mV/mm, 0.3 µm/ppm and 36 aF/0.1 bar, respectively. The main advantage of implementing micro electro mechanical system devices is to reduce the size and cost and also to improve the sensitivity. Along with IOT, smart sensor technology is also introduced in the monitoring which avoids the serious problems that occur in wind mills.
- 1 May 2019
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 60 (1_suppl) , 3052-3068
RetractedRETRACTED: IOT-based oil condition monitoring of wind turbine gear boxes with smart sensor technology
The performance parameters such as viscosity, humidity and pressure of the gear box lubricating oil should be monitored and controlled to improve the efficiency of the windmill. The recent technique like Internet Of Things is used for the continuous transmission of bulk data of these parameters from one machine to other machine which is situated in remote locations. Also the development of mobile technology and web made the live monitoring easier. Thus, transmission and sharing of data takes place without any time delay. The technology also helps to completely eliminate the assistance nearby the site. The large wind farms in coastal areas are easily and continuously monitored and the data are recorded from remote locations with the mobile technology having internet connections. This paper also reports the novelty in the design of micro electro mechanical systems viscosity sensor, micro electro mechanical system humidity sensor and micro electro mechanical system pressure sensor for continuous monitoring of the lubricating system. The following are the principles used for the sensor design such as thermal actuation for viscosity measurement, cantilever principle for humidity and capacitive type for pressure measurement. The sensitivity of micro electro mechanical system viscosity sensor, micro electro mechanical system humidity sensor and micro electro mechanical system pressure sensor are 0.5–0.75 mV/mm, 0.3 µm/ppm and 36 aF/0.1 bar, respectively. The main advantage of implementing micro electro mechanical system devices is to reduce the size and cost and also to improve the sensitivity. Along with IOT, smart sensor technology is also introduced in the monitoring which avoids the serious problems that occur in wind mills.
- 1 February 2017
- Published by American Scientific Publishers in Journal of Computational and Theoretical Nanoscience
- Vol. 14 (2) , 1035-1041
A Low Cost Sensor System for Monitoring Wind Turbine Gear Box Lubrication System
An increased demand for performance assessment of the oil has made to develop a sensor system for monitoring the lubricating system. Development of MEMS technology has taken place to fabricate the sensor array for detecting the condition of oil by measuring the parameters such as Viscosity, Humidity and Pressure. Viscosity of the oil is measured with a diaphragm which is vibrated at its resonant frequency by applying current to the actuator. Damping is provided by the oil. When the viscosity of the oil changes, the stress induced in the diaphragm also changes. The change in stress can be calculated with a help of piezoresistors. The sensitivity of the sensor lies in the range of 0.5 to 0.75 μmV/mm. For humidity sensing, the micro cantilever is coated with polyimide. Due to the absorption of water vapour present in the oil, expansion of polyimide takes place. The stress induced in the cantilever due to the swelling of polyimide is proportional to the humidity to be measured. The sensitivity of the sensor lies in the range of 0.3 μm/ppm. The pressure sensor is a capacitive pressure sensor which has several capacitors designed like a comb for capacitive sensing and to improve the sensitivity mechanical sensing element is isolated from the electrical sensing element. The sensitivity of the sensor lies in the range of 36 aF/0.1 bar.
- 1 February 2017
- Published by American Scientific Publishers in Journal of Computational and Theoretical Nanoscience
- Vol. 14 (2) , 1035-1041
A Low Cost Sensor System for Monitoring Wind Turbine Gear Box Lubrication System
An increased demand for performance assessment of the oil has made to develop a sensor system for monitoring the lubricating system. Development of MEMS technology has taken place to fabricate the sensor array for detecting the condition of oil by measuring the parameters such as Viscosity, Humidity and Pressure. Viscosity of the oil is measured with a diaphragm which is vibrated at its resonant frequency by applying current to the actuator. Damping is provided by the oil. When the viscosity of the oil changes, the stress induced in the diaphragm also changes. The change in stress can be calculated with a help of piezoresistors. The sensitivity of the sensor lies in the range of 0.5 to 0.75 μmV/mm. For humidity sensing, the micro cantilever is coated with polyimide. Due to the absorption of water vapour present in the oil, expansion of polyimide takes place. The stress induced in the cantilever due to the swelling of polyimide is proportional to the humidity to be measured. The sensitivity of the sensor lies in the range of 0.3 μm/ppm. The pressure sensor is a capacitive pressure sensor which has several capacitors designed like a comb for capacitive sensing and to improve the sensitivity mechanical sensing element is isolated from the electrical sensing element. The sensitivity of the sensor lies in the range of 36 aF/0.1 bar.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-199
Comparitive analysis of capacitive type MEMS pressure sensor for altitude sensing
This paper reports on comparison, selection, design and simulation of various types of MEMS based capacitive type pressure sensor for altitude measurement. The widely used capacitive type pressure sensor is analyzed by simulating its diaphragm deflection, capacitance change etc. for a pressure range of 0-1.1 MPa (Mega Pascal) and its merits and demerits are discussed. Also a new design is proposed to overcome the demerits of capacitive sensor.
- 1 December 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-199
Comparitive analysis of capacitive type MEMS pressure sensor for altitude sensing
This paper reports on comparison, selection, design and simulation of various types of MEMS based capacitive type pressure sensor for altitude measurement. The widely used capacitive type pressure sensor is analyzed by simulating its diaphragm deflection, capacitance change etc. for a pressure range of 0-1.1 MPa (Mega Pascal) and its merits and demerits are discussed. Also a new design is proposed to overcome the demerits of capacitive sensor.