Behnam Jafari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Behnam Jafari has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Saeed Golmohammadi
Faculty of Electrical and Computer Engineering University of Tabriz 5166616471 Tabriz
8 shared publications- Elnaz Gholizadeh
Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
6 shared publications - Ehsan Adibnia
Faculty of Electrical and Computer Engineering, University of Sistan and Baluchestan, Zahedan, Iran
5 shared publications Elnaz Gholizadeh
Faculty of Electrical and Computer Engineering University of Tabriz 5166616471 Tabriz
5 shared publications- Hadi Soofi
Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran
5 shared publications Ali Abbasifakher
Malayer University
3 shared publications
Latest Publications
- 17 October 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (11) , 2526
Compact and efficient NAND logic gate based on photonic crystal cavities
We propose a compact NAND logic gate implemented in a photonic crystal platform featuring a novel, to our knowledge, architecture with four optimized cavity resonators. The device achieves high-performance metrics, including a contrast ratio of 44.52 dB, a fast response time of 0.18 ps, and a theoretical maximum bit rate of 5.55 Tbit/s. Finite-difference time-domain simulations confirm robust operation across a wide temperature range with negligible performance degradation. The design occupies a footprint of only 84.84µm 2 , marking a substantial reduction in device dimensions compared to existing implementations while maintaining CMOS compatibility. Our comprehensive benchmarking against reported architectures establishes the superior performance of this design in terms of switching speed, signal integrity, and power consumption. These results demonstrate a viable pathway toward practical, large-scale optical computing systems and next-generation optical communication networks.
- 17 October 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (11) , 2526
Compact and efficient NAND logic gate based on photonic crystal cavities
We propose a compact NAND logic gate implemented in a photonic crystal platform featuring a novel, to our knowledge, architecture with four optimized cavity resonators. The device achieves high-performance metrics, including a contrast ratio of 44.52 dB, a fast response time of 0.18 ps, and a theoretical maximum bit rate of 5.55 Tbit/s. Finite-difference time-domain simulations confirm robust operation across a wide temperature range with negligible performance degradation. The design occupies a footprint of only 84.84µm 2 , marking a substantial reduction in device dimensions compared to existing implementations while maintaining CMOS compatibility. Our comprehensive benchmarking against reported architectures establishes the superior performance of this design in terms of switching speed, signal integrity, and power consumption. These results demonstrate a viable pathway toward practical, large-scale optical computing systems and next-generation optical communication networks.
- Open Access
- 17 June 2025
- Published by Springer Nature in Research Square
Enhanced Plasmon-Induced Transparency for Slow-Light Applications in an Ingenious Architecture of Asymmetrical Square Ring Resonators Integrated with Optical Switching and its high effect on the performance of a proposed index sensor and all optical logical Gates
This Study proposes an asymmetrically coupled square ring resonator coupled to a metal-insulator metal waveguide to optimize slow-light manipulation and refractive index sensing based on plasmon-induced transparency. The asymmetrical design facilitates differential excitation of the incoming light and the induced plasmons and thus interference patterns, which are responsible for power enhancement in certain input ports while blocking others. This mechanism gives higher delay times and pronounced slow-light effects. This, in turn, has greatly enhanced the sensitivity and figures of merit compared to the symmetrical structure, which suffers from lower delay times that reduce sensitivity. Such a dynamical process may result in different output modes with distinct resonator wavelengths depending on the size and propagation delays. 3D FDTD simulations indicate significant sensitivity enhancement with FOMs of 1900, 2000, 1600, and 1600 for the different modes featuring an ng of 95 and a corresponding delay of 34. These results further pinpoint the capabilities of the asymmetrical structure to work as a versatile sensor and optical switch, opening new ways toward ultra-compact devices for biomedical sensing, environmental monitoring, and high-speed communications. The multi-mode features of the output slow light system which originated from Asymmetrical SRRs lead to its tunability to be adjusted in any wavelength of interest in which specific modes have specified delay time, group index, FOM, sensitivity, and phase shift, which can be chosen from a wide range of 200 to 2000 nm included telecommunication band, moreover in this study reaching to negative delay time which originates from negative group velocity (Index) cause to the phase velocity of the SPPs waves can exceed the speed of light in vacuum, leading to unusual propagation characteristic in one hand and Superluminal Propagation in another hand enrich its performance and FOM in terms of optical switching and high modulation speed. The proposed structure presents a groundbreaking advancement in the fields of optical encoders, logically integrated circuits, and optical computing, opening new possibilities for enhanced functionality and innovation.
- 17 June 2025
- Published by Springer Nature in Research Square
Open AccessEnhanced Plasmon-Induced Transparency for Slow-Light Applications in an Ingenious Architecture of Asymmetrical Square Ring Resonators Integrated with Optical Switching and its high effect on the performance of a proposed index sensor and all optical logical Gates
This Study proposes an asymmetrically coupled square ring resonator coupled to a metal-insulator metal waveguide to optimize slow-light manipulation and refractive index sensing based on plasmon-induced transparency. The asymmetrical design facilitates differential excitation of the incoming light and the induced plasmons and thus interference patterns, which are responsible for power enhancement in certain input ports while blocking others. This mechanism gives higher delay times and pronounced slow-light effects. This, in turn, has greatly enhanced the sensitivity and figures of merit compared to the symmetrical structure, which suffers from lower delay times that reduce sensitivity. Such a dynamical process may result in different output modes with distinct resonator wavelengths depending on the size and propagation delays. 3D FDTD simulations indicate significant sensitivity enhancement with FOMs of 1900, 2000, 1600, and 1600 for the different modes featuring an ng of 95 and a corresponding delay of 34. These results further pinpoint the capabilities of the asymmetrical structure to work as a versatile sensor and optical switch, opening new ways toward ultra-compact devices for biomedical sensing, environmental monitoring, and high-speed communications. The multi-mode features of the output slow light system which originated from Asymmetrical SRRs lead to its tunability to be adjusted in any wavelength of interest in which specific modes have specified delay time, group index, FOM, sensitivity, and phase shift, which can be chosen from a wide range of 200 to 2000 nm included telecommunication band, moreover in this study reaching to negative delay time which originates from negative group velocity (Index) cause to the phase velocity of the SPPs waves can exceed the speed of light in vacuum, leading to unusual propagation characteristic in one hand and Superluminal Propagation in another hand enrich its performance and FOM in terms of optical switching and high modulation speed. The proposed structure presents a groundbreaking advancement in the fields of optical encoders, logically integrated circuits, and optical computing, opening new possibilities for enhanced functionality and innovation.
- Open Access
- 10 April 2025
- Published by Elsevier in Results in Optics
- Vol. 21
High-performance and compact photonic crystal channel drop filter using P-shaped ring resonator
- 10 April 2025
- Published by Elsevier in Results in Optics
- Vol. 21
Open AccessHigh-performance and compact photonic crystal channel drop filter using P-shaped ring resonator
- Open Access
- 6 January 2025
- Published by Optica Publishing Group in Optica Open
Plasmon-Induced Transparency in Square Ring Resonator Structures for Optical Switch and Slow-Light Applications
In this study, we introduce an innovative plasmonic structure utilizing a Metal-Insulator-Metal (MIM) waveguide that interacts with an A symmetric square ring resonator, designed specifically for enhanced control of slow-light effects and refractive index sensing. By leveraging the phenomenon of Plasmon-Induced Transparency (PIT), our approach addresses and overcomes key limitations associated with traditional Electromagnetically Induced Transparency (EIT). Using Finite Difference Time Domain (FDTD) simulations, we explore the capabilities of this design, demonstrating significant improvements in refractive index sensitivity and notable slow-light effects. The findings highlight the potential of this structure in advancing integrated photonic devices and in applications requiring high precision. The sensitivity achieved, represented by figures of merit (FOM) for different modes, displays values of 1900, 2000, 1600, and 1600, indicating its strong performance as a versatile sensor. Additionally, when employed in slow-light applications, the group index (ng) and delay values were recorded at 95 and 34, respectively, in addition, the proposed structure has the capability to function as a sensor and switcher, along with its main function of slow light functionality, making this design a promising candidate for next-generation optical systems.
- 6 January 2025
- Published by Optica Publishing Group in Optica Open
Open AccessPlasmon-Induced Transparency in Square Ring Resonator Structures for Optical Switch and Slow-Light Applications
In this study, we introduce an innovative plasmonic structure utilizing a Metal-Insulator-Metal (MIM) waveguide that interacts with an A symmetric square ring resonator, designed specifically for enhanced control of slow-light effects and refractive index sensing. By leveraging the phenomenon of Plasmon-Induced Transparency (PIT), our approach addresses and overcomes key limitations associated with traditional Electromagnetically Induced Transparency (EIT). Using Finite Difference Time Domain (FDTD) simulations, we explore the capabilities of this design, demonstrating significant improvements in refractive index sensitivity and notable slow-light effects. The findings highlight the potential of this structure in advancing integrated photonic devices and in applications requiring high precision. The sensitivity achieved, represented by figures of merit (FOM) for different modes, displays values of 1900, 2000, 1600, and 1600, indicating its strong performance as a versatile sensor. Additionally, when employed in slow-light applications, the group index (ng) and delay values were recorded at 95 and 34, respectively, in addition, the proposed structure has the capability to function as a sensor and switcher, along with its main function of slow light functionality, making this design a promising candidate for next-generation optical systems.
- Open Access
- 6 January 2025
- Published by Optica Publishing Group in Optica Open
Plasmon-Induced Transparency in Square Ring Resonator Structures for Optical Switch and Slow-Light Applications
In this study, we introduce an innovative plasmonic structure utilizing a Metal-Insulator-Metal (MIM) waveguide that interacts with an A symmetric square ring resonator, designed specifically for enhanced control of slow-light effects and refractive index sensing. By leveraging the phenomenon of Plasmon-Induced Transparency (PIT), our approach addresses and overcomes key limitations associated with traditional Electromagnetically Induced Transparency (EIT). Using Finite Difference Time Domain (FDTD) simulations, we explore the capabilities of this design, demonstrating significant improvements in refractive index sensitivity and notable slow-light effects. The findings highlight the potential of this structure in advancing integrated photonic devices and in applications requiring high precision. The sensitivity achieved, represented by figures of merit (FOM) for different modes, displays values of 1900, 2000, 1600, and 1600, indicating its strong performance as a versatile sensor. Additionally, when employed in slow-light applications, the group index (ng) and delay values were recorded at 95 and 34, respectively, in addition, the proposed structure has the capability to function as a sensor and switcher, along with its main function of slow light functionality, making this design a promising candidate for next-generation optical systems.
- 6 January 2025
- Published by Optica Publishing Group in Optica Open
Open AccessPlasmon-Induced Transparency in Square Ring Resonator Structures for Optical Switch and Slow-Light Applications
In this study, we introduce an innovative plasmonic structure utilizing a Metal-Insulator-Metal (MIM) waveguide that interacts with an A symmetric square ring resonator, designed specifically for enhanced control of slow-light effects and refractive index sensing. By leveraging the phenomenon of Plasmon-Induced Transparency (PIT), our approach addresses and overcomes key limitations associated with traditional Electromagnetically Induced Transparency (EIT). Using Finite Difference Time Domain (FDTD) simulations, we explore the capabilities of this design, demonstrating significant improvements in refractive index sensitivity and notable slow-light effects. The findings highlight the potential of this structure in advancing integrated photonic devices and in applications requiring high precision. The sensitivity achieved, represented by figures of merit (FOM) for different modes, displays values of 1900, 2000, 1600, and 1600, indicating its strong performance as a versatile sensor. Additionally, when employed in slow-light applications, the group index (ng) and delay values were recorded at 95 and 34, respectively, in addition, the proposed structure has the capability to function as a sensor and switcher, along with its main function of slow light functionality, making this design a promising candidate for next-generation optical systems.
- 13 December 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (36) , 9337-9346
High-speed all-optical symmetric 4 × 2 encoder using interface effects in two-dimensional photonic crystals
This paper focuses on designing and simulating a 4×2 all-optical encoder utilizing the wave interference effect within photonic crystals. The proposed structure includes four optical waveguides as inputs and two as outputs, with a total area of 133.9µm2. The encoder demonstrates a response time of 0.44 ps, a contrast ratio of approximately 13.3 dB, and a data transfer rate of 2.3 Tbit/s. The results highlight the structure’s high flexibility, efficient resolution, and competitive response time compared to other designs in this category, demonstrating its practical applicability, particularly for signal division tasks. The finite-difference time-domain technique and the plane wave expansion method were employed to analyze the simulation outcomes and determine the optical bandgap range essential for the design.
- 13 December 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (36) , 9337-9346
High-speed all-optical symmetric 4 × 2 encoder using interface effects in two-dimensional photonic crystals
This paper focuses on designing and simulating a 4×2 all-optical encoder utilizing the wave interference effect within photonic crystals. The proposed structure includes four optical waveguides as inputs and two as outputs, with a total area of 133.9µm2. The encoder demonstrates a response time of 0.44 ps, a contrast ratio of approximately 13.3 dB, and a data transfer rate of 2.3 Tbit/s. The results highlight the structure’s high flexibility, efficient resolution, and competitive response time compared to other designs in this category, demonstrating its practical applicability, particularly for signal division tasks. The finite-difference time-domain technique and the plane wave expansion method were employed to analyze the simulation outcomes and determine the optical bandgap range essential for the design.
- Open Access
- 27 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Highly sensitive label-free biosensor: graphene/CaF2 multilayer for gas, cancer, virus, and diabetes detection with enhanced quality factor and figure of merit
One of the primary goals for the researchers is to create a high-quality sensor with a simple structure because of the urgent requirement to identify biomolecules at low concentrations to diagnose diseases and detect hazardous chemicals for health early on. Recently graphene has attracted much interest in the field of improved biosensors. Meanwhile, graphene with new materials such as CaF2has been widely used to improve the applications of graphene-based sensors. Using the fantastic features of the graphene/CaF2multilayer, this article proposes an improvement sensor in the sensitivity (S), the figure of merit (FOM), and the quality factor (Q). The proposed sensor is based on the five-layers graphene/dielectric grating integrated with a Fabry–Perot cavity. By tuning graphene chemical potential (µc), due to the semi-metal features of graphene, the surface plasmon resonance (SPR) waves excited at the graphene/dielectric boundaries. Due to the vertical polarization of the source to the gratings and the symmetry of the electric field, both corners of the grating act as electric dipoles, and this causes the propagation of plasmonic waves on the graphene surface to propagate towards each other. Finally, it causes Fabry–Perot (FP) interference on the surface of graphene in the proposed structure's active medium (the area where the sample is located). In this article, using the inherent nature of FP interference and its S to the environment's refractive index (RI), by changing a minimal amount in the RI of the sample, the resonance wavelength (interferometer order) shifts sharply. The proposed design can detect and sense some cancers, such as Adrenal Gland Cancer, Blood Cancer, Breast Cancer I, Breast Cancer II, Cervical Cancer, and skin cancer precisely. By optimizing the structure, we can achieve an S as high as 9000 nm/RIU and a FOM of about 52.14 for the first resonance order (M1). Likewise, the remarkable S of 38,000 nm/RIU and the FOM of 81 have been obtained for the second mode (M2). In addition, the proposed label-free SPR sensor can detect changes in the concentration of various materials, including gases and biomolecules, hemoglobin, breast cancer, diabetes, leukemia, and most alloys, with an accuracy of 0.001. The proposed sensor can sense urine concentration with a maximum S of 8500 nm/RIU and cancers with high S in the 6000 nm/RIU range to 7000 nm/RIU. Also, four viruses, such as M13 bacteriophage, HIV type one, Herpes simplex type 1, and influenza, have been investigated, showing Maximum S (for second resonance mode of λR(M2) of 8000 nm/RIU (λR(M2) = 11.2 µm), 12,000 nm/RIU (λR(M2) = 10.73 µm), 38,000 nm/RIU (λR(M2) = 11.78 µm), and 12,000 nm/RIU (λR(M2) = 10.6 µm), respectively, and the obtained S for first resonance mode (λR(M1)) for mentioned viruses are 4740 nm/RIU (λR(M1) = 8.7 µm), 8010 nm/RIU (λR(M1) = 8.44 µm), 8100 nm/RIU (λR(M1) = 10.15 µm), and 9000 (λR(M1) = 8.36 µm), respectively.
- 27 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-15
Open AccessHighly sensitive label-free biosensor: graphene/CaF2 multilayer for gas, cancer, virus, and diabetes detection with enhanced quality factor and figure of merit
One of the primary goals for the researchers is to create a high-quality sensor with a simple structure because of the urgent requirement to identify biomolecules at low concentrations to diagnose diseases and detect hazardous chemicals for health early on. Recently graphene has attracted much interest in the field of improved biosensors. Meanwhile, graphene with new materials such as CaF2has been widely used to improve the applications of graphene-based sensors. Using the fantastic features of the graphene/CaF2multilayer, this article proposes an improvement sensor in the sensitivity (S), the figure of merit (FOM), and the quality factor (Q). The proposed sensor is based on the five-layers graphene/dielectric grating integrated with a Fabry–Perot cavity. By tuning graphene chemical potential (µc), due to the semi-metal features of graphene, the surface plasmon resonance (SPR) waves excited at the graphene/dielectric boundaries. Due to the vertical polarization of the source to the gratings and the symmetry of the electric field, both corners of the grating act as electric dipoles, and this causes the propagation of plasmonic waves on the graphene surface to propagate towards each other. Finally, it causes Fabry–Perot (FP) interference on the surface of graphene in the proposed structure's active medium (the area where the sample is located). In this article, using the inherent nature of FP interference and its S to the environment's refractive index (RI), by changing a minimal amount in the RI of the sample, the resonance wavelength (interferometer order) shifts sharply. The proposed design can detect and sense some cancers, such as Adrenal Gland Cancer, Blood Cancer, Breast Cancer I, Breast Cancer II, Cervical Cancer, and skin cancer precisely. By optimizing the structure, we can achieve an S as high as 9000 nm/RIU and a FOM of about 52.14 for the first resonance order (M1). Likewise, the remarkable S of 38,000 nm/RIU and the FOM of 81 have been obtained for the second mode (M2). In addition, the proposed label-free SPR sensor can detect changes in the concentration of various materials, including gases and biomolecules, hemoglobin, breast cancer, diabetes, leukemia, and most alloys, with an accuracy of 0.001. The proposed sensor can sense urine concentration with a maximum S of 8500 nm/RIU and cancers with high S in the 6000 nm/RIU range to 7000 nm/RIU. Also, four viruses, such as M13 bacteriophage, HIV type one, Herpes simplex type 1, and influenza, have been investigated, showing Maximum S (for second resonance mode of λR(M2) of 8000 nm/RIU (λR(M2) = 11.2 µm), 12,000 nm/RIU (λR(M2) = 10.73 µm), 38,000 nm/RIU (λR(M2) = 11.78 µm), and 12,000 nm/RIU (λR(M2) = 10.6 µm), respectively, and the obtained S for first resonance mode (λR(M1)) for mentioned viruses are 4740 nm/RIU (λR(M1) = 8.7 µm), 8010 nm/RIU (λR(M1) = 8.44 µm), 8100 nm/RIU (λR(M1) = 10.15 µm), and 9000 (λR(M1) = 8.36 µm), respectively.
- Open Access
- 6 June 2023
- Published by Springer Nature in Research Square
Ultrasensitive and label-free, graphene/CaF2 multilayer-based biosensor for detecting gasses, cancers, viruses, and diabetes, with significant improvement of sensitivity, quality factor, and figure of merit
One of the primary goals for the researchers is to create a high-quality sensor with a simple structure because of the urgent requirement to identify biomolecules at low concentrations to diagnose diseases and detect hazardous chemicals for health early on. Recently graphene has attracted much interest in the field of improved biosensors. Meanwhile, graphene with new materials such as CaF2 has been widely used to improve the applications of graphene-based sensors. Using the fantastic features of the graphene/CaF2 multilayer, this article proposes an improvement sensor in the sensitivity (S), the figure of merit (FOM), and the quality factor (Q). The proposed sensor is based on the five-layers graphene/dielectric grating integrated with a Fabry-Perot cavity. By tuning graphene chemical potential (µc), due to the semi-metal features of graphene, the surface plasmon resonance (SPR) waves excited at the graphene/dielectric boundaries. Due to the vertical polarization of the source to the gratings and the symmetry of the electric field, both corners of the grating act as electric dipoles, and this causes the propagation of plasmonic waves on the graphene surface to propagate towards each other. Finally, it causes Fabry-Perot (FP) interference on the surface of graphene in the proposed structure's active medium (the area where the sample is located). In this article, using the inherent nature of FP interference and its S to the environment's refractive index (RI), by changing a minimal amount in the RI of the sample, the resonance wavelength (interferometer order) shifts sharply. The proposed design can detect and sense some cancer, such as Adrenal Gland Cancer, Blood Cancer, Breast Cancer I, Breast Cancer II, Cervical Cancer, and skin cancer precisely. By optimizing the structure, we can achieve an S as high as 9000 nm/RIU and a FOM of about 52.14 for the first resonance order (M1). Likewise, the remarkable S of 38000 nm/RIU and the FOM of 81 have been obtained for the second mode (M2). In addition, the proposed label-free SPR sensor can detect changes in the concentration of various materials, including gases and biomolecules, hemoglobin, breast cancer, diabetes, leukemia, and most alloys, with an accuracy of 0.001. The proposed sensor can sense urine concentration with a maximum S of 8500 nm/RIU and cancers with high S in the 6000 nm/RIU range to 7000 nm/RIU. Also, four viruses, such as M13 bacteriophage, HIV type one, Herpes simplex type 1, and influenza, have been investigated, showing Maximum S (for second resonance mode of λR(M2) of 8000 nm/RIU (λR(M2) = 11.2 µm), 12000 nm/RIU (λR(M2) = 10.73 µm), 38000 nm/RIU (λR(M2) = 11.78 µm), and 12000 nm/RIU (λR(M2) = 10.6 µm), respectively, and the obtained S for first resonance mode (λR(M1)) for mentioned viruses are 4740 nm/RIU (λR(M1) = 8.7 µm), 8010 nm/RIU (λR(M1) = 8.44 µm), 8100 nm/RIU (λR(M1) = 10.15 µm), and 9000 (λR(M1) = 8.36 µm), respectively.
- 6 June 2023
- Published by Springer Nature in Research Square
Open AccessUltrasensitive and label-free, graphene/CaF2 multilayer-based biosensor for detecting gasses, cancers, viruses, and diabetes, with significant improvement of sensitivity, quality factor, and figure of merit
One of the primary goals for the researchers is to create a high-quality sensor with a simple structure because of the urgent requirement to identify biomolecules at low concentrations to diagnose diseases and detect hazardous chemicals for health early on. Recently graphene has attracted much interest in the field of improved biosensors. Meanwhile, graphene with new materials such as CaF2 has been widely used to improve the applications of graphene-based sensors. Using the fantastic features of the graphene/CaF2 multilayer, this article proposes an improvement sensor in the sensitivity (S), the figure of merit (FOM), and the quality factor (Q). The proposed sensor is based on the five-layers graphene/dielectric grating integrated with a Fabry-Perot cavity. By tuning graphene chemical potential (µc), due to the semi-metal features of graphene, the surface plasmon resonance (SPR) waves excited at the graphene/dielectric boundaries. Due to the vertical polarization of the source to the gratings and the symmetry of the electric field, both corners of the grating act as electric dipoles, and this causes the propagation of plasmonic waves on the graphene surface to propagate towards each other. Finally, it causes Fabry-Perot (FP) interference on the surface of graphene in the proposed structure's active medium (the area where the sample is located). In this article, using the inherent nature of FP interference and its S to the environment's refractive index (RI), by changing a minimal amount in the RI of the sample, the resonance wavelength (interferometer order) shifts sharply. The proposed design can detect and sense some cancer, such as Adrenal Gland Cancer, Blood Cancer, Breast Cancer I, Breast Cancer II, Cervical Cancer, and skin cancer precisely. By optimizing the structure, we can achieve an S as high as 9000 nm/RIU and a FOM of about 52.14 for the first resonance order (M1). Likewise, the remarkable S of 38000 nm/RIU and the FOM of 81 have been obtained for the second mode (M2). In addition, the proposed label-free SPR sensor can detect changes in the concentration of various materials, including gases and biomolecules, hemoglobin, breast cancer, diabetes, leukemia, and most alloys, with an accuracy of 0.001. The proposed sensor can sense urine concentration with a maximum S of 8500 nm/RIU and cancers with high S in the 6000 nm/RIU range to 7000 nm/RIU. Also, four viruses, such as M13 bacteriophage, HIV type one, Herpes simplex type 1, and influenza, have been investigated, showing Maximum S (for second resonance mode of λR(M2) of 8000 nm/RIU (λR(M2) = 11.2 µm), 12000 nm/RIU (λR(M2) = 10.73 µm), 38000 nm/RIU (λR(M2) = 11.78 µm), and 12000 nm/RIU (λR(M2) = 10.6 µm), respectively, and the obtained S for first resonance mode (λR(M1)) for mentioned viruses are 4740 nm/RIU (λR(M1) = 8.7 µm), 8010 nm/RIU (λR(M1) = 8.44 µm), 8100 nm/RIU (λR(M1) = 10.15 µm), and 9000 (λR(M1) = 8.36 µm), respectively.
- Open Access
- 14 March 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1
Author Correction: Graphene-based optofluidic tweezers for refractive-index and size-based nanoparticle sorting, manipulation, and detection
- 14 March 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1
Open AccessAuthor Correction: Graphene-based optofluidic tweezers for refractive-index and size-based nanoparticle sorting, manipulation, and detection
- Open Access
- 3 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
Graphene-based optofluidic tweezers for refractive-index and size-based nanoparticle sorting, manipulation, and detection
This work proposes a novel design composed of graphene nanoribbons-based optofluidic tweezers to manipulate and sort bio-particles with radii below 2.5 nm. The suggested structure has been numerically investigated by the finite difference time domain (FDTD) method employing Maxwell's stress tensor analysis (MST). The finite element method (FEM) has been used to obtain the electrostatic response of the proposed structure. The tweezer main path is a primary channel in the center of the structure, where the microfluidic flow translates the nanoparticle toward this channel. Concerning the microfluid's drag force, the nanoparticles tend to move along the length of the main channel. The graphene nanoribbons are fixed near the main channel at different distances to exert optical forces on the moving nanoparticles in the perpendicular direction. In this regard, sub-channels embedding in the hBN layer on the Si substrate deviate bio-particles from the main path for particular nanoparticle sizes and indices. Intense hotspots with electric field enhancements up to 900 times larger than the incident light are realized inside and around the graphene ribbons. Adjusting the gap distance between the graphene nanoribbon and the main channel allows us to separate the individual particle with a specific size from others, thus guiding that in the desired sub-channel. Furthermore, we demonstrated that in a structure with a large gap between channels, particles experience weak field intensity, leading to a low optical force that is insufficient to detect, trap, and manipulate nanoparticles. By varying the chemical potential of graphene associated with the electric field intensity variations in the graphene ribbons, we realized tunability in sorting nanoparticles while structural parameters remained constant. In fact, by adjusting the graphene Fermi level via the applied gate voltage, nanoparticles with any desired radius will be quickly sorted. Moreover, we exhibited that the proposed structure could sort nanoparticles based on their refractive indices. Therefore, the given optofluidic tweezer can easily detect bio-particles, such as cancer cells and viruses of tiny size.
- 3 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
Open AccessGraphene-based optofluidic tweezers for refractive-index and size-based nanoparticle sorting, manipulation, and detection
This work proposes a novel design composed of graphene nanoribbons-based optofluidic tweezers to manipulate and sort bio-particles with radii below 2.5 nm. The suggested structure has been numerically investigated by the finite difference time domain (FDTD) method employing Maxwell's stress tensor analysis (MST). The finite element method (FEM) has been used to obtain the electrostatic response of the proposed structure. The tweezer main path is a primary channel in the center of the structure, where the microfluidic flow translates the nanoparticle toward this channel. Concerning the microfluid's drag force, the nanoparticles tend to move along the length of the main channel. The graphene nanoribbons are fixed near the main channel at different distances to exert optical forces on the moving nanoparticles in the perpendicular direction. In this regard, sub-channels embedding in the hBN layer on the Si substrate deviate bio-particles from the main path for particular nanoparticle sizes and indices. Intense hotspots with electric field enhancements up to 900 times larger than the incident light are realized inside and around the graphene ribbons. Adjusting the gap distance between the graphene nanoribbon and the main channel allows us to separate the individual particle with a specific size from others, thus guiding that in the desired sub-channel. Furthermore, we demonstrated that in a structure with a large gap between channels, particles experience weak field intensity, leading to a low optical force that is insufficient to detect, trap, and manipulate nanoparticles. By varying the chemical potential of graphene associated with the electric field intensity variations in the graphene ribbons, we realized tunability in sorting nanoparticles while structural parameters remained constant. In fact, by adjusting the graphene Fermi level via the applied gate voltage, nanoparticles with any desired radius will be quickly sorted. Moreover, we exhibited that the proposed structure could sort nanoparticles based on their refractive indices. Therefore, the given optofluidic tweezer can easily detect bio-particles, such as cancer cells and viruses of tiny size.