Toms Torims
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Toms Torims has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Abraham Tishelman-Charny
Physics Department, Brookhaven National Laboratory
9 shared publications - Albert De Roeck
European Organization for Nuclear Research
9 shared publications - Alberto Ruiz Jimeno
Instituto de Física de Cantabria
9 shared publications - Alessandro Rossi
Università di Perugia
9 shared publications - Andre David
European Organization for Nuclear Research
9 shared publications - Andre Sznajder
Universidade do Estado do Rio de Janeiro
9 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Erratum to: Future Circular Collider Feasibility Study Report
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessErratum to: Future Circular Collider Feasibility Study Report
- Open Access
- 7 March 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 16
An Alvarez-Type Linac Configuration for Future Carbon and Helium Ion Therapy Facilities with Parallel Radioisotope Production
The increasing demand for ion beams heavier than protons—particularly carbon and helium ions—for cancer therapy has driven the development of advanced accelerator technologies. Although proton therapy is well established, its physical properties limit its effectiveness against certain tumor types, thereby motivating the use of ions with higher linear energy transfer (LET) and greater biological effectiveness. This study presents the design of an Alvarez-type linear accelerator configuration that combines a Quasi-Alvarez Drift Tube Linac (QA-DTL) and a conventional Alvarez Drift Tube Linac (DTL). The proposed systems are intended for accelerating and injecting carbon or helium ions into a cancer therapy synchrotron, as well as accelerating helium ions for radioisotope production. The optimized QA-DTL and DTL structures provide a versatile and efficient solution for future particle therapy facilities, addressing the growing demand for compact, high-performance, and multifunctional accelerator systems. The proposed linac configurations are designed to operate at 352.2 MHz and consist of three sections. For accelerating low-velocity ions, the first section is a QA-DTL, which is the only section powered during the injection of carbon or helium ions (depending on configuration) into the therapy synchrotron at the energy of 5 MeV/u. The QA-DTL is followed by two DTL cavities forming the second and third sections, which further accelerate helium ions to energies of up to 7.1 MeV/u and 10 MeV/u, respectively. The energy of 7.1 MeV/u is chosen because it represents the production threshold of 211At, one of the most promising alpha emitters for targeted alpha therapy.
- 7 March 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 16
Open AccessAn Alvarez-Type Linac Configuration for Future Carbon and Helium Ion Therapy Facilities with Parallel Radioisotope Production
The increasing demand for ion beams heavier than protons—particularly carbon and helium ions—for cancer therapy has driven the development of advanced accelerator technologies. Although proton therapy is well established, its physical properties limit its effectiveness against certain tumor types, thereby motivating the use of ions with higher linear energy transfer (LET) and greater biological effectiveness. This study presents the design of an Alvarez-type linear accelerator configuration that combines a Quasi-Alvarez Drift Tube Linac (QA-DTL) and a conventional Alvarez Drift Tube Linac (DTL). The proposed systems are intended for accelerating and injecting carbon or helium ions into a cancer therapy synchrotron, as well as accelerating helium ions for radioisotope production. The optimized QA-DTL and DTL structures provide a versatile and efficient solution for future particle therapy facilities, addressing the growing demand for compact, high-performance, and multifunctional accelerator systems. The proposed linac configurations are designed to operate at 352.2 MHz and consist of three sections. For accelerating low-velocity ions, the first section is a QA-DTL, which is the only section powered during the injection of carbon or helium ions (depending on configuration) into the therapy synchrotron at the energy of 5 MeV/u. The QA-DTL is followed by two DTL cavities forming the second and third sections, which further accelerate helium ions to energies of up to 7.1 MeV/u and 10 MeV/u, respectively. The energy of 7.1 MeV/u is chosen because it represents the production threshold of 211At, one of the most promising alpha emitters for targeted alpha therapy.
- Top Cited PapersOpen Access
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Future Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Top Cited PapersOpen AccessFuture Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- Open Access
- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5)
Erratum to: Search for resonant and nonresonant production of pairs of dijet resonances in proton-proton collisions at $ \sqrt{s} $ = 13 TeV- 14 May 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (5)
Open AccessErratum to: Search for resonant and nonresonant production of pairs of dijet resonances in proton-proton collisions at $ \sqrt{s} $ = 13 TeV - Open Access
Lumped Parameter Model for Structural Analysis of Over-Constrained Multi-Legged Parallel Mechanism Supporting System Applied to Cryogenic Devices
While the design of a cryostat is being developed, one of the most relevant sub-systems is the internal supporting system that sustains the cooled component. According to the literature, the arrangement and number of supports chosen often result in a multi-leg over-constrained architecture. These are usually studied by means of finite element analysis tools alone, which makes studies like the optimization of supporting systems computationally expensive. This paper proposes a more structured and general analytical model compared to the existing models for this application. The proposed lumped parameter model allows designers to study the influence of external loads, pre-load, and cool-down on stress levels and deformation status of the supports of the cryogenic device as well as the consequent misalignment of the cooled component. The general lumped parameter model for n tie-rods of different shapes, dimensions, and materials is proposed. Two particularized models of eight and eleven supports are validated by comparing the results with those from standard finite element analysis software. Results show that the proposed model has a strong agreement with finite element simulations, and the median of relative errors is about 1.4%. This accuracy is obtained for models of randomly arranged supports, which proves the effectiveness of the model in predicting results even for non-symmetrical support configurations. Comparable and accurate results are obtained, which are about 130 times faster than in finite element analysis, thus proving the effective reduction in computational cost. Additionally, the proposed code lets designers change input parameters in a quicker and reliable way.
Open AccessLumped Parameter Model for Structural Analysis of Over-Constrained Multi-Legged Parallel Mechanism Supporting System Applied to Cryogenic Devices
While the design of a cryostat is being developed, one of the most relevant sub-systems is the internal supporting system that sustains the cooled component. According to the literature, the arrangement and number of supports chosen often result in a multi-leg over-constrained architecture. These are usually studied by means of finite element analysis tools alone, which makes studies like the optimization of supporting systems computationally expensive. This paper proposes a more structured and general analytical model compared to the existing models for this application. The proposed lumped parameter model allows designers to study the influence of external loads, pre-load, and cool-down on stress levels and deformation status of the supports of the cryogenic device as well as the consequent misalignment of the cooled component. The general lumped parameter model for n tie-rods of different shapes, dimensions, and materials is proposed. Two particularized models of eight and eleven supports are validated by comparing the results with those from standard finite element analysis software. Results show that the proposed model has a strong agreement with finite element simulations, and the median of relative errors is about 1.4%. This accuracy is obtained for models of randomly arranged supports, which proves the effectiveness of the model in predicting results even for non-symmetrical support configurations. Comparable and accurate results are obtained, which are about 130 times faster than in finite element analysis, thus proving the effective reduction in computational cost. Additionally, the proposed code lets designers change input parameters in a quicker and reliable way.
- Open Access
- 1 November 2024
- Published by Springer Nature in Meccanica
- Vol. 59 (12) , 2203-2226
Design of a 6-supports exactly constrained supporting system for superconducting magnets and its application to rotating gantries for cancer therapy
In particle therapy for cancer treatment, the radiation dose to tissues around the tumour can be reduced by employing a rotating gantry—a mechanical structure allowing the delivery of the particle beam to the patient from various angles. Gantries for ion therapy can benefit from the integration of superconducting magnets to minimize the size and weight of the machine. One significant challenge associated with the supporting system of superconducting elements is related to the management of their accuracy during both alignment and operational phases. Concurrently, heat flow from room temperature to cryogenic temperatures through the supporting system must be restricted as the ratio of power needed to operate the cooling system is around 1000 times the power extracted at cryogenic temperature. The design of the supports must consider the variability of the load during operation, i.e. guarantee accuracy of the cold-mass pose (position and rotation) under its own weight during a $${360\,\mathrm{ ^{\circ }}}$$ gantry rotation. A literature review had been done highlighting the possible application of a novel exact-constrained solution for the support of superconducting magnets. Within the framework of the European project HITRIplus (heavy Ion Therapy Research Integration), this study proposes the design and optimization of a support system based on a $$6$$ degrees of freedom parallel mechanism (exactly constrained kinematics). A mathematical model is proposed, referred as “error model”, to estimate the accuracy of the pose of the cold-mass due to major unrecoverable errors. The error model estimates the contribution of main error sources: the elasticity of the supports, the elasticity of the vacuum vessel enclosure and the influence of backlash in the joints. An optimization genetic algorithm has been developed and employed to find the optimal configuration of supports that simultaneously increases the accuracy and minimizes heat-loads to the cold-mass. The error model has been validated by finite element analysis, showing its validity for the optimization process. The optimised solution has been compared to solutions that were proposed initially based on common sense, intuition and had been manually refined: the optimized solution shows considerable improvements in the overall accuracy of the system and a substantial reduction of the heat-loads. The optimized solution also implements a pre-load system to eliminate backlash in the joints: this considerably improves the accuracy of the system. The error model presented allows computationally cheaper optimizations and variations of the designed architecture (i.e. variation in cross sections, change in material, change in geometry, implementation of pre-load etc...) with respect to a classic approach based only on finite element analysis. Furthermore, thanks to the kinematics characteristic of the proposed architecture, the 6-legs design clears the way for a more reliable implementation of an automated positioning system with respect to classical over-constrained architectures.- 1 November 2024
- Published by Springer Nature in Meccanica
- Vol. 59 (12) , 2203-2226
Open AccessDesign of a 6-supports exactly constrained supporting system for superconducting magnets and its application to rotating gantries for cancer therapy
In particle therapy for cancer treatment, the radiation dose to tissues around the tumour can be reduced by employing a rotating gantry—a mechanical structure allowing the delivery of the particle beam to the patient from various angles. Gantries for ion therapy can benefit from the integration of superconducting magnets to minimize the size and weight of the machine. One significant challenge associated with the supporting system of superconducting elements is related to the management of their accuracy during both alignment and operational phases. Concurrently, heat flow from room temperature to cryogenic temperatures through the supporting system must be restricted as the ratio of power needed to operate the cooling system is around 1000 times the power extracted at cryogenic temperature. The design of the supports must consider the variability of the load during operation, i.e. guarantee accuracy of the cold-mass pose (position and rotation) under its own weight during a $${360\,\mathrm{ ^{\circ }}}$$ gantry rotation. A literature review had been done highlighting the possible application of a novel exact-constrained solution for the support of superconducting magnets. Within the framework of the European project HITRIplus (heavy Ion Therapy Research Integration), this study proposes the design and optimization of a support system based on a $$6$$ degrees of freedom parallel mechanism (exactly constrained kinematics). A mathematical model is proposed, referred as “error model”, to estimate the accuracy of the pose of the cold-mass due to major unrecoverable errors. The error model estimates the contribution of main error sources: the elasticity of the supports, the elasticity of the vacuum vessel enclosure and the influence of backlash in the joints. An optimization genetic algorithm has been developed and employed to find the optimal configuration of supports that simultaneously increases the accuracy and minimizes heat-loads to the cold-mass. The error model has been validated by finite element analysis, showing its validity for the optimization process. The optimised solution has been compared to solutions that were proposed initially based on common sense, intuition and had been manually refined: the optimized solution shows considerable improvements in the overall accuracy of the system and a substantial reduction of the heat-loads. The optimized solution also implements a pre-load system to eliminate backlash in the joints: this considerably improves the accuracy of the system. The error model presented allows computationally cheaper optimizations and variations of the designed architecture (i.e. variation in cross sections, change in material, change in geometry, implementation of pre-load etc...) with respect to a classic approach based only on finite element analysis. Furthermore, thanks to the kinematics characteristic of the proposed architecture, the 6-legs design clears the way for a more reliable implementation of an automated positioning system with respect to classical over-constrained architectures. - Open Access
- 7 October 2024
- Published by CERN in Open Research Europe
- Vol. 2, 55
Comparative study on scenarios for rotating gantry mechanical structures
Background This paper outlines a comparative study on scenarios of gantries mechanical design for ion-therapy of cancer, which is a crucial step toward the development of the next ion medical machine. Methods Multiple scenarios were considered based on robustness of the design, size, weight and complexity, deformation and precision performances and costs, as well as environmental impact. Four prospective scenarios were identified, each of them capable of providing beam to at least 220°around the patient. One scenario is capable of providing treatment angles of 360°. This report will describe the unified methodology performed during the study in order to achieve unbiased results in a comprehensive manner. Results Results show that in statically balanced scenarios, considerable improvements can be reached in terms of safety, deformation, precision performances, complexity and costs of implementation. Conclusions All scenarios are deemed suitable for further gantry design development.
- 7 October 2024
- Published by CERN in Open Research Europe
- Vol. 2, 55
Open AccessComparative study on scenarios for rotating gantry mechanical structures
Background This paper outlines a comparative study on scenarios of gantries mechanical design for ion-therapy of cancer, which is a crucial step toward the development of the next ion medical machine. Methods Multiple scenarios were considered based on robustness of the design, size, weight and complexity, deformation and precision performances and costs, as well as environmental impact. Four prospective scenarios were identified, each of them capable of providing beam to at least 220°around the patient. One scenario is capable of providing treatment angles of 360°. This report will describe the unified methodology performed during the study in order to achieve unbiased results in a comprehensive manner. Results Results show that in statically balanced scenarios, considerable improvements can be reached in terms of safety, deformation, precision performances, complexity and costs of implementation. Conclusions All scenarios are deemed suitable for further gantry design development.
- Open Access
- 17 May 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (5) , 054801
Metal additive manufacturing for particle accelerator applications
Metal additive manufacturing technologies are rapidly becoming an integral part of the advanced technological portfolio for the most demanding industrial applications. These processes are capable of fabricating three-dimensional components with near-net shape quality by depositing the constituent materials in a layer-by-layer fashion. This fabrication approach provides numerous advantages over conventional manufacturing methods, including enhanced design flexibility, reduced production costs and lead times, rapid prototyping, and the possibility to repair damaged parts. In recent years, the growing demand for novel accelerator components with improved performance characteristics, integrating structures such as drift tubes and internal cooling channels, has prompted the exploration of additive manufacturing in the field of particle accelerators. Radio-frequency components, beam intercepting devices, and vacuum systems have been prototyped using various metallic materials and additive manufacturing technologies, demonstrating performance levels comparable to the conventionally manufactured counterparts in preliminary tests. However, the absence of established qualification protocols and the uncertain reliability of additively manufactured parts under the demanding conditions typical of accelerator applications pose significant challenges to the integration of additive manufacturing processes into the fabrication practices of these components. This paper provides a comprehensive review of documented applications of metal additive manufacturing in particle accelerators, highlighting benefits, challenges, and opportunities for future improvements. The main requirements and currently available test setups for the assessment of additively manufactured components in applications involving ultrahigh vacuum and intense electromagnetic fields are also discussed. Published by the American Physical Society 2024
- 17 May 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (5) , 054801
Open AccessMetal additive manufacturing for particle accelerator applications
Metal additive manufacturing technologies are rapidly becoming an integral part of the advanced technological portfolio for the most demanding industrial applications. These processes are capable of fabricating three-dimensional components with near-net shape quality by depositing the constituent materials in a layer-by-layer fashion. This fabrication approach provides numerous advantages over conventional manufacturing methods, including enhanced design flexibility, reduced production costs and lead times, rapid prototyping, and the possibility to repair damaged parts. In recent years, the growing demand for novel accelerator components with improved performance characteristics, integrating structures such as drift tubes and internal cooling channels, has prompted the exploration of additive manufacturing in the field of particle accelerators. Radio-frequency components, beam intercepting devices, and vacuum systems have been prototyped using various metallic materials and additive manufacturing technologies, demonstrating performance levels comparable to the conventionally manufactured counterparts in preliminary tests. However, the absence of established qualification protocols and the uncertain reliability of additively manufactured parts under the demanding conditions typical of accelerator applications pose significant challenges to the integration of additive manufacturing processes into the fabrication practices of these components. This paper provides a comprehensive review of documented applications of metal additive manufacturing in particle accelerators, highlighting benefits, challenges, and opportunities for future improvements. The main requirements and currently available test setups for the assessment of additively manufactured components in applications involving ultrahigh vacuum and intense electromagnetic fields are also discussed. Published by the American Physical Society 2024
- Open Access
Literature Review of Suspension Systems for Superconducting Elements
When designing suspension systems for superconducting elements, the primary challenge is to strike a balance between limiting the heat load to the cold mass and ensuring the proper mechanical resistance and/or stiffness of the system. This trade-off often leads engineers to choose from a limited set of materials and supporting architectures. The aim of this study is to provide an overview of the different overall designs. Scientific articles were searched within the Google Scholar database using advanced search operators to combine a defined set of keywords. Among the architectures found, the “multi-post” solution and the “8-support” solution are the two most commonly chosen classes. Additionally, a recurrent pattern for the supporting system of superconducting cavities has been identified. The choice of architecture can be correlated with the characteristics of the superconducting element being supported, such as its mass, length, and stiffness. Furthermore, the review provides a conceptual analysis of the possibility of extending these designs to the unconventional environment of rotating machines.
Open AccessLiterature Review of Suspension Systems for Superconducting Elements
When designing suspension systems for superconducting elements, the primary challenge is to strike a balance between limiting the heat load to the cold mass and ensuring the proper mechanical resistance and/or stiffness of the system. This trade-off often leads engineers to choose from a limited set of materials and supporting architectures. The aim of this study is to provide an overview of the different overall designs. Scientific articles were searched within the Google Scholar database using advanced search operators to combine a defined set of keywords. Among the architectures found, the “multi-post” solution and the “8-support” solution are the two most commonly chosen classes. Additionally, a recurrent pattern for the supporting system of superconducting cavities has been identified. The choice of architecture can be correlated with the characteristics of the superconducting element being supported, such as its mass, length, and stiffness. Furthermore, the review provides a conceptual analysis of the possibility of extending these designs to the unconventional environment of rotating machines.