Mohonish N. Chettri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohonish N. Chettri has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
A M Singh
Department of Immunohaematology and Blood Transfusion, Regional Institute of Medical Sciences, Imphal, India
1 shared publication- Anup Pradhan
Department of Gynecology and Obstetrics, Sikkim Manipal Institute of Medical Sciences, Sikkim Manipal University, Gangtok, Sikkim, India
1 shared publication - Chamma Gupta
Department of Biochemistry, Sikkim Manipal Institute of Medical Sciences, Sikkim Manipal University, Gangtok, India
1 shared publication Gulshana Akthar
Sikkim Manipal University, Gangtok Sikkim, India
1 shared publicationHari Shanker Sharma
Manipal - TATA Medical College, Jamshedpur, India
1 shared publicationJeevitha Kondaveety
Department of Otorhinolaryngology, Head and Neck Surgery, Central Referral Hospital, Sikkim Manipal Institute of Medical Sciences, Sikkim Manipal University, Gangtok, India
1 shared publication
Latest Publications
- 2 August 2025
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 77 (12) , 5335-5341
Hearing Sensitivity and Threshold in Children with Developmental and Behavioural Disorders: A Cross-Sectional Study
- 2 August 2025
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 77 (12) , 5335-5341
Hearing Sensitivity and Threshold in Children with Developmental and Behavioural Disorders: A Cross-Sectional Study
- 26 January 2024
- Published by Springer Nature in Indian Journal of Clinical Biochemistry
- Vol. 40 (2) , 245-253
Genomic DNA Extraction from Different Human Tissue Sample: Urine, Oral Gargle, Blood, and Cervical for Real Time Amplification by qPCR
Molecular technologies have been a driver of rapid paradigm shift in the field of scientific research and clinical applications. Adequate and pure form of nucleic acid extracted from efficient biological sources together with an easy, simple, standardized protocol, ease of access and acceptability is also a prerequisite for genotyping analysis for different disorders. Urine and oral gargle samples are emerging as a potential source of genomic DNA (gDNA) and may offer a better alternative to existing sources such as blood. This manuscript compares for the first time, the quality and quantity of gDNA extracted manually by standard methods from different biological samples like urine, oral gargle, blood and cervical samples, together. It aimed to assess the feasibility of extracting sufficient gDNA from easily accessible and acceptable samples for amplification. 646 urine, oral, blood and cervical samples were collected from different studies in the department and analyzed. gDNA from blood was extracted by Proteinase K digestion followed by ethanol precipitation, and phenol–chloroform extraction method for urine, oral gargle and cervical specimen. The quantification of isolated gDNA were analyzed in Nano-drop spectrophotometer and 1% Agarose gel electrophoresis for different sample types. Human β-globin gene were used for internal quality control for the real time amplification. DNA quantity and purity were adequate and comparable for amplification in all the three biological samples with an average A 260/280 ratio of 1.8, 1.7 and 1.7 for gDNA isolated from urine, oral gargle and blood samples, respectively (n = 200 each). The mean DNA yield from urine, oral and blood samples were 474.9, 899.2 and 489.0 (ng/μl) respectively. The mean concentration of the DNA extracted from cervical smear samples (n = 46) was found to be 318.6 ng/µl with an average A 260/280 of 1.6. The average Cq values obtained were 12.8, 18.5 and 17.9 for β-globin in gDNA isolated from urine, oral and blood samples respectively (n = 50 each). The present study concluded that adequate and pure form of gDNA can be extracted from different biological samples of blood, urine and oral samples using standardized manual DNA extraction protocol. The extracted gDNA was amplified for gene targets as per respective study objectives. Detection of β-globin, IC with Cq cut off value below 30 for adequate internal quality. Genomic DNA extraction was successful from cervical tissue, however, could not be used for like-to-like comparison as it requires further work to elicit successful amplification.
- 26 January 2024
- Published by Springer Nature in Indian Journal of Clinical Biochemistry
- Vol. 40 (2) , 245-253
Genomic DNA Extraction from Different Human Tissue Sample: Urine, Oral Gargle, Blood, and Cervical for Real Time Amplification by qPCR
Molecular technologies have been a driver of rapid paradigm shift in the field of scientific research and clinical applications. Adequate and pure form of nucleic acid extracted from efficient biological sources together with an easy, simple, standardized protocol, ease of access and acceptability is also a prerequisite for genotyping analysis for different disorders. Urine and oral gargle samples are emerging as a potential source of genomic DNA (gDNA) and may offer a better alternative to existing sources such as blood. This manuscript compares for the first time, the quality and quantity of gDNA extracted manually by standard methods from different biological samples like urine, oral gargle, blood and cervical samples, together. It aimed to assess the feasibility of extracting sufficient gDNA from easily accessible and acceptable samples for amplification. 646 urine, oral, blood and cervical samples were collected from different studies in the department and analyzed. gDNA from blood was extracted by Proteinase K digestion followed by ethanol precipitation, and phenol–chloroform extraction method for urine, oral gargle and cervical specimen. The quantification of isolated gDNA were analyzed in Nano-drop spectrophotometer and 1% Agarose gel electrophoresis for different sample types. Human β-globin gene were used for internal quality control for the real time amplification. DNA quantity and purity were adequate and comparable for amplification in all the three biological samples with an average A 260/280 ratio of 1.8, 1.7 and 1.7 for gDNA isolated from urine, oral gargle and blood samples, respectively (n = 200 each). The mean DNA yield from urine, oral and blood samples were 474.9, 899.2 and 489.0 (ng/μl) respectively. The mean concentration of the DNA extracted from cervical smear samples (n = 46) was found to be 318.6 ng/µl with an average A 260/280 of 1.6. The average Cq values obtained were 12.8, 18.5 and 17.9 for β-globin in gDNA isolated from urine, oral and blood samples respectively (n = 50 each). The present study concluded that adequate and pure form of gDNA can be extracted from different biological samples of blood, urine and oral samples using standardized manual DNA extraction protocol. The extracted gDNA was amplified for gene targets as per respective study objectives. Detection of β-globin, IC with Cq cut off value below 30 for adequate internal quality. Genomic DNA extraction was successful from cervical tissue, however, could not be used for like-to-like comparison as it requires further work to elicit successful amplification.
- 7 December 2022
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 75 (2) , 1016-1019
Rigid Bronchoscopy–Brief Insight and Encounters in a Tertiary Hospital
A brief insight of Rigid Bronchoscopy and methodology in current times in a tertiary care centre and a series of 3 recent unusual encounters of foreign body removed through rigid bronchoscopy.
- 7 December 2022
- Published by Springer Nature in Indian Journal of Otolaryngology and Head & Neck Surgery
- Vol. 75 (2) , 1016-1019
Rigid Bronchoscopy–Brief Insight and Encounters in a Tertiary Hospital
A brief insight of Rigid Bronchoscopy and methodology in current times in a tertiary care centre and a series of 3 recent unusual encounters of foreign body removed through rigid bronchoscopy.
- Open Access
- 18 May 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 10673-10678
Non-technical skills amongst multidisciplinary surgeons (notss) in a tertiary hospital in India
Non-technical skills for surgeons are a set of skills that are non-surgical in nature but make the surgical procedure safer for the patient. In this context, this is a study in a tertiary hospital where the non-technical skills of multi-disciplinary surgeons were observed and assessed when they were performing live surgeries. We found that none of our participant surgeons were rated poor for any skills, which endangered performance or potentially endangered patient safety and for which serious remediation would have been required. "Acceptable" standards of "Situational Awareness" and "Leadership" and "Good" standards of "Decision Making" and "Communication & Teamwork", which were the four skills observed.
- 18 May 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 10673-10678
Open AccessNon-technical skills amongst multidisciplinary surgeons (notss) in a tertiary hospital in India
Non-technical skills for surgeons are a set of skills that are non-surgical in nature but make the surgical procedure safer for the patient. In this context, this is a study in a tertiary hospital where the non-technical skills of multi-disciplinary surgeons were observed and assessed when they were performing live surgeries. We found that none of our participant surgeons were rated poor for any skills, which endangered performance or potentially endangered patient safety and for which serious remediation would have been required. "Acceptable" standards of "Situational Awareness" and "Leadership" and "Good" standards of "Decision Making" and "Communication & Teamwork", which were the four skills observed.
- 12 July 2019
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 133 (7) , 615-621
Haemostasis and analgesia with autologous platelet-rich plasma in tonsillectomy
Objective: A single-centre, single-blinded prospective experimental study was conducted to determine the effectiveness of autologous platelet-rich plasma applied to the tonsillar bed post-operatively in reducing post-operative pain and haemorrhage.Methods: Platelet-rich plasma, prepared prior to surgery, was applied with calcium gluconate to one randomly chosen tonsillar fossa. Pain and haemorrhage were analysed, using a visual analogue scale and a pre-defined grading scale respectively, four times on the day of surgery at 2-hourly intervals, and thrice on the following day.Results: The pain score and haemorrhage grade on the test side were lower than on the control side. These findings were statistically significant.Conclusion: This pilot study, conducted in India, revealed valid positive results for a promising new technology. The manual preparation of platelet-rich plasma could be automated in the future to allow a larger sample size.
- 12 July 2019
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 133 (7) , 615-621
Haemostasis and analgesia with autologous platelet-rich plasma in tonsillectomy
Objective: A single-centre, single-blinded prospective experimental study was conducted to determine the effectiveness of autologous platelet-rich plasma applied to the tonsillar bed post-operatively in reducing post-operative pain and haemorrhage.Methods: Platelet-rich plasma, prepared prior to surgery, was applied with calcium gluconate to one randomly chosen tonsillar fossa. Pain and haemorrhage were analysed, using a visual analogue scale and a pre-defined grading scale respectively, four times on the day of surgery at 2-hourly intervals, and thrice on the following day.Results: The pain score and haemorrhage grade on the test side were lower than on the control side. These findings were statistically significant.Conclusion: This pilot study, conducted in India, revealed valid positive results for a promising new technology. The manual preparation of platelet-rich plasma could be automated in the future to allow a larger sample size.