Lan Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lan Peng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Haihong Huang
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China
3 shared publications - Sheng Dou
University of Science and Technology of China, Hefei, China
2 shared publications Xu Wu
Hefei University of Technology
2 shared publications- Xu Wu
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications Haihong Huang
Hefei University of Technology
1 shared publication- Haihong Huang
Hefei University of Technology
1 shared publication
Latest Publications
- 16 September 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (3) , 684-703
Junction Temperature Balancing Strategy for Parallel Insulated Gate Bipolar Transistors Based on Thermal Resistance and Gate Resistance Compensation
- 16 September 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (3) , 684-703
Junction Temperature Balancing Strategy for Parallel Insulated Gate Bipolar Transistors Based on Thermal Resistance and Gate Resistance Compensation
- 31 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (12) , 1-11
Research on Magnetically Balanced High-Current TMR Sensor for EAST Poloidal Field Power Supply
A magnetic balanced Tunneling Magneto Resistance (TMR) sensor for high-current measurement was developed to meet the measurement requirements of Experimental Advanced Superconducting Tokamak Poloidal Field (EAST PF) power supply. The difficulty in the research of magnetic balance type high current sensor is to analyze and predict its operating parameters under different working conditions. Analyze the compensation coil, iron core and verify the output parameters of secondary winding based on these operating parameters. In order to obtain the operating parameters under different working conditions, the balance equation of magnetic induction intensity and the characteristic matrix of magnetic balance sensor based on linear assumption are proposed. The operating parameters are simulated by three-dimensional finite element method. Through simulation and experimental test, the measured current values of the secondary coil are compared with the theoretical values. The comparison results are consistent with the theoretical analysis. The sensor prototype is also tested continuously for 24 hours (20 kA current), the compensation coil was not burned out, and the iron core was not saturated. The sensor measurement accuracy was better than 0.4%. The results prove the correctness and practicality of the proposed analysis method. In addition, external magnetic fields and ferromagnetic materials may become sources of external interference, leading to imbalanced operating parameters between secondary windings. If the interference degree is high, it may cause overcurrent and overheating in certain secondary windings.
- 31 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (12) , 1-11
Research on Magnetically Balanced High-Current TMR Sensor for EAST Poloidal Field Power Supply
A magnetic balanced Tunneling Magneto Resistance (TMR) sensor for high-current measurement was developed to meet the measurement requirements of Experimental Advanced Superconducting Tokamak Poloidal Field (EAST PF) power supply. The difficulty in the research of magnetic balance type high current sensor is to analyze and predict its operating parameters under different working conditions. Analyze the compensation coil, iron core and verify the output parameters of secondary winding based on these operating parameters. In order to obtain the operating parameters under different working conditions, the balance equation of magnetic induction intensity and the characteristic matrix of magnetic balance sensor based on linear assumption are proposed. The operating parameters are simulated by three-dimensional finite element method. Through simulation and experimental test, the measured current values of the secondary coil are compared with the theoretical values. The comparison results are consistent with the theoretical analysis. The sensor prototype is also tested continuously for 24 hours (20 kA current), the compensation coil was not burned out, and the iron core was not saturated. The sensor measurement accuracy was better than 0.4%. The results prove the correctness and practicality of the proposed analysis method. In addition, external magnetic fields and ferromagnetic materials may become sources of external interference, leading to imbalanced operating parameters between secondary windings. If the interference degree is high, it may cause overcurrent and overheating in certain secondary windings.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2907-2916
Static Current Balancing Strategy for Parallel IGBTs Based on Parametric Compensation
Insulated gate bipolar transistor (IGBT) parallel connection is an effective way to solve the problem, which is the gradual increase in the capacity of the magnetic confinement power supply in a Tokamak device. Static current balance (SCB) is one of the key factors for the safe and stable operation of a parallel IGBT system. Therefore, to improve the stability of parallel IGBT systems, it is very important to study the current difference in the parallel IGBTs under various parameter differences. However, the existing results have focused mainly on device parameter matching through device screening, driving parameter matching using the active gate driving (AGD) method, or single parasitic parameter (PP) matching. These research results do not analyze the matching strategy between multiple parameters, which are the device parameter and the PP. The study showed that the collector inductance, emitter parasitic inductance, emitter parasitic resistance, collector equivalent resistance, and equivalent series voltage of the IGBTs have a significant impact on the SCB of the parallel IGBTs. When these five parameters are mismatched, there exists an equilibrium point that can reduce the static current difference (SCD) between the parallel IGBTs under the total influence of these parameter differences. Therefore, a current difference model (CDM) is created to analyze the equilibrium point of multiple parameter mismatches. The experimental results show that the multiparameter compensation scheme implemented by the CDM can effectively reduce the current difference between parallel IGBTs, which provides a feasible reference for device selection and circuit design.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2907-2916
Static Current Balancing Strategy for Parallel IGBTs Based on Parametric Compensation
Insulated gate bipolar transistor (IGBT) parallel connection is an effective way to solve the problem, which is the gradual increase in the capacity of the magnetic confinement power supply in a Tokamak device. Static current balance (SCB) is one of the key factors for the safe and stable operation of a parallel IGBT system. Therefore, to improve the stability of parallel IGBT systems, it is very important to study the current difference in the parallel IGBTs under various parameter differences. However, the existing results have focused mainly on device parameter matching through device screening, driving parameter matching using the active gate driving (AGD) method, or single parasitic parameter (PP) matching. These research results do not analyze the matching strategy between multiple parameters, which are the device parameter and the PP. The study showed that the collector inductance, emitter parasitic inductance, emitter parasitic resistance, collector equivalent resistance, and equivalent series voltage of the IGBTs have a significant impact on the SCB of the parallel IGBTs. When these five parameters are mismatched, there exists an equilibrium point that can reduce the static current difference (SCD) between the parallel IGBTs under the total influence of these parameter differences. Therefore, a current difference model (CDM) is created to analyze the equilibrium point of multiple parameter mismatches. The experimental results show that the multiparameter compensation scheme implemented by the CDM can effectively reduce the current difference between parallel IGBTs, which provides a feasible reference for device selection and circuit design.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (9) , 3499-3505
Research on Temperature Compensation Method for CRAFT Dot Matrix Hall High Current Sensor
To meet the measurement needs of high current in the comprehensive research facility for fusion technology (CRAFT) power supply, a non-magnetic core direct measurement dot matrix Hall high current sensor has been developed. Hall elements have high sensitivity and wide measurement linear range characteristics, making them suitable for high current measurement occasions. As a semiconductor component, the resistivity, mobility, and carrier concentration of its semiconductor material are all functions of temperature, which can cause changes in parameters such as Hall potential, sensitivity coefficient, and internal resistance with temperature, thereby affecting the sensor’s measurement accuracy. Therefore, the temperature compensation method must be taken to ensure signal measurement accuracy. The traditional constant voltage source input compensation method ignores the internal resistance of the constant voltage source. The constant current source input compensation method ignores the quadratic term of temperature change. Both of them are incomplete compensations. This article proposes a constant current source dual compensation method based on two compensation methods. The constant current source dual compensation method can further improve the temperature characteristics of the sensor and enhance the adaptability of the dot matrix Hall current sensor to the environment. According to the simulation and on-site experimental results, the proposed constant current source dual compensation method can effectively reduce the influence of temperature on the parameter error of Hall elements, thereby significantly improving the sensor’s measurement accuracy.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (9) , 3499-3505
Research on Temperature Compensation Method for CRAFT Dot Matrix Hall High Current Sensor
To meet the measurement needs of high current in the comprehensive research facility for fusion technology (CRAFT) power supply, a non-magnetic core direct measurement dot matrix Hall high current sensor has been developed. Hall elements have high sensitivity and wide measurement linear range characteristics, making them suitable for high current measurement occasions. As a semiconductor component, the resistivity, mobility, and carrier concentration of its semiconductor material are all functions of temperature, which can cause changes in parameters such as Hall potential, sensitivity coefficient, and internal resistance with temperature, thereby affecting the sensor’s measurement accuracy. Therefore, the temperature compensation method must be taken to ensure signal measurement accuracy. The traditional constant voltage source input compensation method ignores the internal resistance of the constant voltage source. The constant current source input compensation method ignores the quadratic term of temperature change. Both of them are incomplete compensations. This article proposes a constant current source dual compensation method based on two compensation methods. The constant current source dual compensation method can further improve the temperature characteristics of the sensor and enhance the adaptability of the dot matrix Hall current sensor to the environment. According to the simulation and on-site experimental results, the proposed constant current source dual compensation method can effectively reduce the influence of temperature on the parameter error of Hall elements, thereby significantly improving the sensor’s measurement accuracy.
- 19 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (6) , 1962-1970
Algorithm Research on the Conductor Eccentricity of a Circular Dot Matrix Hall High Current Sensor for ITER
To meet the high current measurement requirements of the international thermonuclear experimental reactor polar field (ITER PF) power supply, a noncontact dot matrix Hall high current sensor without a magnetic core is designed. Due to the existence of installation error, the measurement accuracy will be reduced due to conductor eccentricity in practical use. To solve this problem, this article will take the circular dot matrix Hall current sensor composed of eight Hall elements as an example and note the shortcomings of the two algorithms by analyzing the numerical integration algorithm and conductor positioning algorithm. Based on the two algorithms, a digital signal processing (DSP) conditioning algorithm is proposed. The DSP conditioning algorithm detects the output voltage of each Hall element after conductor offset and adjusts the output voltage of each Hall element by self-feedback, which simplifies the complexity of algorithm operation and eliminates conductor eccentricity error at the same time. Through simulation and field measurement verification, DSP self-feedback conditioning of the Hall element output voltage can eliminate the influence of conductor eccentricity error and improve the measurement accuracy of the sensor.
- 19 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 50 (6) , 1962-1970
Algorithm Research on the Conductor Eccentricity of a Circular Dot Matrix Hall High Current Sensor for ITER
To meet the high current measurement requirements of the international thermonuclear experimental reactor polar field (ITER PF) power supply, a noncontact dot matrix Hall high current sensor without a magnetic core is designed. Due to the existence of installation error, the measurement accuracy will be reduced due to conductor eccentricity in practical use. To solve this problem, this article will take the circular dot matrix Hall current sensor composed of eight Hall elements as an example and note the shortcomings of the two algorithms by analyzing the numerical integration algorithm and conductor positioning algorithm. Based on the two algorithms, a digital signal processing (DSP) conditioning algorithm is proposed. The DSP conditioning algorithm detects the output voltage of each Hall element after conductor offset and adjusts the output voltage of each Hall element by self-feedback, which simplifies the complexity of algorithm operation and eliminates conductor eccentricity error at the same time. Through simulation and field measurement verification, DSP self-feedback conditioning of the Hall element output voltage can eliminate the influence of conductor eccentricity error and improve the measurement accuracy of the sensor.