Qingkui Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingkui Yu has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Bo Mei
China Academy of Space Technology, Beijing, China
5 shared publicationsYi Sun
China Academy of Space Technology, Beijing, China
4 shared publicationsHe Lv
China Acad Space Technol, Beijing 100080, Peoples R China
3 shared publicationsHongwei Zhang
China Academy of Space Technology, Beijing, China
3 shared publicationsQianyuan Wang
China Academy of Space Technology, Beijing, China
3 shared publicationsShuang Cao
China Academy of Space Technology, Beijing, China
3 shared publications
Latest Publications
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2419-2425
Effect of Heavy-Ion-Induced Latent Damage on SiC MOSFETs’ Gate Reliability
This study investigated the impact of latent damage induced by heavy ions on the gate reliability of 1200 V SiC MOSFETs. Irradiation was conducted using Kr and Ta ions, with linear energy transfer (LET) of 38.85 MeV·cm²/mg and 86.03 MeV·cm²/mg, respectively. Devices exhibiting latent damage underwent a 1000-hour assessment at a gate voltage of 20 V. The findings revealed a significant increase in gate leakage current after the assessment, which is presumed to be caused by trap-assisted tunneling effects. Furthermore, latent damage resulted in a reduction of gate breakdown voltage by approximately 50%. The research also indicated that latent damage did not significantly affect the threshold voltage and transfer characteristics of the devices, suggesting that they retained a degree of gate control capability. Two potential explanations are proposed, providing new insights into the long-term reliability evaluation of SiC MOSFETs post-irradiation.
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2419-2425
Effect of Heavy-Ion-Induced Latent Damage on SiC MOSFETs’ Gate Reliability
This study investigated the impact of latent damage induced by heavy ions on the gate reliability of 1200 V SiC MOSFETs. Irradiation was conducted using Kr and Ta ions, with linear energy transfer (LET) of 38.85 MeV·cm²/mg and 86.03 MeV·cm²/mg, respectively. Devices exhibiting latent damage underwent a 1000-hour assessment at a gate voltage of 20 V. The findings revealed a significant increase in gate leakage current after the assessment, which is presumed to be caused by trap-assisted tunneling effects. Furthermore, latent damage resulted in a reduction of gate breakdown voltage by approximately 50%. The research also indicated that latent damage did not significantly affect the threshold voltage and transfer characteristics of the devices, suggesting that they retained a degree of gate control capability. Two potential explanations are proposed, providing new insights into the long-term reliability evaluation of SiC MOSFETs post-irradiation.
- Open Access
- 29 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (8) , 970
An Optimal Design Method for Lightweight Heating Film of Anisotropic Heat Conduction Substrate Based on Surrogate Model
In space missions, heating films are crucial for uniformly heating onboard equipment for precise temperature control. This study develops an optimization method using surrogate models for lightweight anisotropic substrate thermal conductive heating films, meeting the requirements of uniform heating in thermal control for space applications. A feedforward neural network optimized by particle swarm optimization (PSO) was employed to create a surrogate model, mapping design parameters to the temperature uniformity of the heating film. This model served as the basis for applying the NSGA-II algorithm to quickly optimize both temperature uniformity and lightweight characteristics. In this study, the PSO-BP surrogate model was trained using heating film thermal simulation data, and the surrogate model demonstrated an accurate prediction of the mean square error (MSE) of the predicted temperature difference within 0.0168 s. The maximum temperature difference in the optimal model is 1.188 ℃, which is 30.5 times lower than before optimization, and the equivalent density is only increased by 3.9%. In summary, this optimization design method effectively captures the relationships among various parameters and optimization objectives. Its superior computational accuracy and design efficiency offer significant advantages in the design of devices such as heating films.
- 29 July 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (8) , 970
Open AccessAn Optimal Design Method for Lightweight Heating Film of Anisotropic Heat Conduction Substrate Based on Surrogate Model
In space missions, heating films are crucial for uniformly heating onboard equipment for precise temperature control. This study develops an optimization method using surrogate models for lightweight anisotropic substrate thermal conductive heating films, meeting the requirements of uniform heating in thermal control for space applications. A feedforward neural network optimized by particle swarm optimization (PSO) was employed to create a surrogate model, mapping design parameters to the temperature uniformity of the heating film. This model served as the basis for applying the NSGA-II algorithm to quickly optimize both temperature uniformity and lightweight characteristics. In this study, the PSO-BP surrogate model was trained using heating film thermal simulation data, and the surrogate model demonstrated an accurate prediction of the mean square error (MSE) of the predicted temperature difference within 0.0168 s. The maximum temperature difference in the optimal model is 1.188 ℃, which is 30.5 times lower than before optimization, and the equivalent density is only increased by 3.9%. In summary, this optimization design method effectively captures the relationships among various parameters and optimization objectives. Its superior computational accuracy and design efficiency offer significant advantages in the design of devices such as heating films.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (9) , 2165-2174
Special Degradation Effects of 60Co γ-Rays Irradiation on Electrical Parameters of SiC MOSFETs
The static and dynamic characteristics of SiC MOSFETs under gate and drain biases exhibit differential degradation after irradiation. Total ionizing dose (TID) irradiation caused threshold voltage shift and switch response degradation, and the degradation trends of these two parameters were not the same dependence on the bias. The threshold voltage of devices under test (DUT) shifted toward negative due to the radiation-induced positive oxide trapped charges. Turn-off time (t off ) was more sensitive to TID irradiation compared to turn-on time (t on ). The switch response changed after irradiation due to parasitic capacitance C GD and threshold voltage degradation. It has been verified by Sentaurus TCAD 2D simulations that the high-speed accumulation of gate oxide traps in the localized region of the trench gate MOS (UMOS) due to the non-uniform distribution of the electric field is the main reason for the special degradation of electrical parameters under drain bias. For TID radiation damage evaluation and radiation hardening of SiC MOSFETs under different biases, both static and dynamic performance should be considered. The experimental results provide valuable insights into the behavior of SiC MOSFETs under radiation and are crucial for designing reliable electronic systems for space and nuclear applications.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (9) , 2165-2174
Special Degradation Effects of 60Co γ-Rays Irradiation on Electrical Parameters of SiC MOSFETs
The static and dynamic characteristics of SiC MOSFETs under gate and drain biases exhibit differential degradation after irradiation. Total ionizing dose (TID) irradiation caused threshold voltage shift and switch response degradation, and the degradation trends of these two parameters were not the same dependence on the bias. The threshold voltage of devices under test (DUT) shifted toward negative due to the radiation-induced positive oxide trapped charges. Turn-off time (t off ) was more sensitive to TID irradiation compared to turn-on time (t on ). The switch response changed after irradiation due to parasitic capacitance C GD and threshold voltage degradation. It has been verified by Sentaurus TCAD 2D simulations that the high-speed accumulation of gate oxide traps in the localized region of the trench gate MOS (UMOS) due to the non-uniform distribution of the electric field is the main reason for the special degradation of electrical parameters under drain bias. For TID radiation damage evaluation and radiation hardening of SiC MOSFETs under different biases, both static and dynamic performance should be considered. The experimental results provide valuable insights into the behavior of SiC MOSFETs under radiation and are crucial for designing reliable electronic systems for space and nuclear applications.
- 4 July 2023
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 178 (9-10) , 1063-1072
Temperature and total ionizing dose effects of SiC MOSFET and their synergistic characteristics
- 4 July 2023
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 178 (9-10) , 1063-1072
Temperature and total ionizing dose effects of SiC MOSFET and their synergistic characteristics
- 21 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1885-1891
Displacement Damage Equivalence of Neutron and Proton Radiations in Triple-Junction GaInP/GaAs/Ge Solar Cells
In this work, radiation effects in GaInP/GaAs/Ge triple junction solar cells irradiated by 3 MeV, 5 MeV, 10 MeV, 60 MeV, 100 MeV protons, and 1 MeV equivalent neutrons are investigated. The external quantum efficiency (EQE), open-circuit voltage ( V oc ), maximum power ( P max ), and conversion efficiency ( E ff ) of solar cells are measured and compared. The Geant4 software is utilized to simulate non-ionizing energy loss (NIEL) with different particles. The physical mechanisms behind the different phenomena of device performance degradation due to neutron, low-energy proton, and high-energy proton irradiations at the same displacement damage dose are analyzed. The proportion of Primary Knock-on Atom (PKA) number produced by neutrons and low-energy protons is consistent with that of NIEL, but the proportion of PKA number produced by high-energy protons is not consistent with that of NIEL. The energy spectrum of PKA is investigated, and it is proposed that different energies and types of PKA may lead to different defect morphologies. The displacement damage dose method is used to determine the radiation damage equivalent between protons and neutrons, and the equivalent relationship between V oc , P max , and E ff is given. The results prove that the neutron source can be used as an alternative particle source for on-orbit solar cells to predict the performance degradation caused by protons.
- 21 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1885-1891
Displacement Damage Equivalence of Neutron and Proton Radiations in Triple-Junction GaInP/GaAs/Ge Solar Cells
In this work, radiation effects in GaInP/GaAs/Ge triple junction solar cells irradiated by 3 MeV, 5 MeV, 10 MeV, 60 MeV, 100 MeV protons, and 1 MeV equivalent neutrons are investigated. The external quantum efficiency (EQE), open-circuit voltage ( V oc ), maximum power ( P max ), and conversion efficiency ( E ff ) of solar cells are measured and compared. The Geant4 software is utilized to simulate non-ionizing energy loss (NIEL) with different particles. The physical mechanisms behind the different phenomena of device performance degradation due to neutron, low-energy proton, and high-energy proton irradiations at the same displacement damage dose are analyzed. The proportion of Primary Knock-on Atom (PKA) number produced by neutrons and low-energy protons is consistent with that of NIEL, but the proportion of PKA number produced by high-energy protons is not consistent with that of NIEL. The energy spectrum of PKA is investigated, and it is proposed that different energies and types of PKA may lead to different defect morphologies. The displacement damage dose method is used to determine the radiation damage equivalent between protons and neutrons, and the equivalent relationship between V oc , P max , and E ff is given. The results prove that the neutron source can be used as an alternative particle source for on-orbit solar cells to predict the performance degradation caused by protons.
- 25 September 2022
- Published by Elsevier in Microelectronics Reliability
- Vol. 138
Experimental study of total ionizing dose effect on SiC MOSFETs at temperature from −233 °C to 175 °C
- 25 September 2022
- Published by Elsevier in Microelectronics Reliability
- Vol. 138
Experimental study of total ionizing dose effect on SiC MOSFETs at temperature from −233 °C to 175 °C
- 13 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (5) , 1127-1133
Application of Total Ionizing Dose Radiation Test Standards to SiC MOSFETs
The total ionizing dose (TID) test standards have been developed based on silicon devices to evaluate the TID response of MOS devices for space use. To estimate the applicability of the existing TID test standards to the wide-gap semiconductor silicon carbide (SiC) devices, 1200 V SiC n-channel MOSFETs from three manufacturers were irradiated with Cobalt-60 $\gamma $ -rays at the high radiation dose rate of 50 rad(Si)/s and the low radiation dose rate of 0.01 rad(Si)/s, respectively. The threshold voltage of devices under test (DUT) shifted toward negative due to the radiation-induced positive oxide trapped charges. Room temperature (RT) anneal of maximum time of 2100 h and high temperature (HT) accelerated anneal of maximum temperature of 105 °C were performed, causing the threshold voltage shift to recover. The synergetic effects of temperature-gate-bias stress and TID on SiC MOSFETs were experimentally studied. In conclusion, the degradation of SiC MOSFETs irradiated at high dose rate is dominated by the positive trapped oxide charges, and the existing TID test standards are applicable to evaluate the SiC MOSFETs radiation hardness level, but the threshold voltages shift due to HT-gate-bias (HTGB) should be evaluated.
- 13 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (5) , 1127-1133
Application of Total Ionizing Dose Radiation Test Standards to SiC MOSFETs
The total ionizing dose (TID) test standards have been developed based on silicon devices to evaluate the TID response of MOS devices for space use. To estimate the applicability of the existing TID test standards to the wide-gap semiconductor silicon carbide (SiC) devices, 1200 V SiC n-channel MOSFETs from three manufacturers were irradiated with Cobalt-60 $\gamma $ -rays at the high radiation dose rate of 50 rad(Si)/s and the low radiation dose rate of 0.01 rad(Si)/s, respectively. The threshold voltage of devices under test (DUT) shifted toward negative due to the radiation-induced positive oxide trapped charges. Room temperature (RT) anneal of maximum time of 2100 h and high temperature (HT) accelerated anneal of maximum temperature of 105 °C were performed, causing the threshold voltage shift to recover. The synergetic effects of temperature-gate-bias stress and TID on SiC MOSFETs were experimentally studied. In conclusion, the degradation of SiC MOSFETs irradiated at high dose rate is dominated by the positive trapped oxide charges, and the existing TID test standards are applicable to evaluate the SiC MOSFETs radiation hardness level, but the threshold voltages shift due to HT-gate-bias (HTGB) should be evaluated.
- 1 September 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 88-90, 952-956
Experimental and simulation study of the correlation between displacement damage and incident proton energy for GaAs devices
- 1 September 2018
- Published by Elsevier in Microelectronics Reliability
- Vol. 88-90, 952-956
Experimental and simulation study of the correlation between displacement damage and incident proton energy for GaAs devices
- 1 September 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2005 8th European Conference on Radiation and Its Effects on Components and Systems
- No. 03796566,p. LNW2-1
Experimental Investigation of Radiation Damage on CCD with Protons and Cobalt 60 Gamma Rays
TDI CCD IL-E2-0512B was irradiated with protons and cobalt 60 gamma rays respectively. The doses levels of failure due to displacement damage and/or ionizing radiation were obtained. The total ionizing dose (TID) and displace damage dose (DDD) on orbit are calculated. It is concluded that the proton's displacement damage is dominated the degradation of IL-E2-0512B in space environment. The method to quantitative evaluate the degradation of CCD in space environment is proposed.
- 1 September 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2005 8th European Conference on Radiation and Its Effects on Components and Systems
- No. 03796566,p. LNW2-1
Experimental Investigation of Radiation Damage on CCD with Protons and Cobalt 60 Gamma Rays
TDI CCD IL-E2-0512B was irradiated with protons and cobalt 60 gamma rays respectively. The doses levels of failure due to displacement damage and/or ionizing radiation were obtained. The total ionizing dose (TID) and displace damage dose (DDD) on orbit are calculated. It is concluded that the proton's displacement damage is dominated the degradation of IL-E2-0512B in space environment. The method to quantitative evaluate the degradation of CCD in space environment is proposed.