    Numerical Study on Heat Transfer Characteristics of Microchannel with Ferrofluid Under Influence of Magnetic Intensity

    by Seong-Guk Hwang, Tai Duc Le, Moo-Yeon Lee

    Effective thermal management is critical for high-power lithium-ion batteries to mitigate excessive heat generation and ensure operational reliability. Failure to maintain a uniform temperature distribution can lead to accelerated capacity fading and severe safety risks, such as thermal runaway. In this study, a ferrofluid-based magnetohydrodynamic (MHD) microchannel cooling system was numerically investigated to elucidate the influence of magnetic intensity, magnet geometry, and electrical boundary conditions on flow behavior and heat transfer performance for battery cooling applications. A fully coupled multiphysics model incorporating electromagnetic, fluid flow, and heat transfer phenomena was developed and validated against experimental and numerical data from the literature. The results show that increasing the applied voltage enhances current density and Lorentz force almost linearly, leading to significant flow acceleration and improved convective heat transfer. Electrical insulation effectively suppresses current leakage into the channel walls, increasing the average current density by up to 222% and the Lorentz force by more than 300%. Compared with a cylindrical magnet, a rectangular magnet provides a more uniform magnetic field distribution and stronger near-wall Lorentz forcing, resulting in superior cooling performance. Under a 4C discharge condition, the insulated rectangular magnet reduces the maximum battery temperature by approximately 30% and increases the average Nusselt number by up to 103% relative to the non-insulated case. The findings reveal the critical roles of magnetic-field-controlled flow symmetry and near-wall forcing in MHD-driven microchannels, and provide practical design guidelines for battery cooling systems with no moving mechanical parts and active electromagnetic flow control.


  • Open Access

    Numerical Analysis on Cooling Performances for Connectors Using Immersion Cooling in Ultra-Fast Chargers for Electric Vehicles

    by Seong-Guk Hwang, Moo-Yeon Lee, Beom-Seok Ko

    The increasing demand for ultra-fast charging in electric vehicles (EVs) necessitates advancements in thermal management strategies to mitigate Joule heating, which arises due to electrical resistance in charging connectors and cable cores. This study presents a numerical analysis of immersion cooling performance for ultra-fast chargers under realistic charging conditions. The simulated results are validated by experiments with a maximum deviation of 5.5% at 600 A and 700 A currents. The novelty of this work lies in the consideration of a realistic charging cable length of 5 m, the evaluation of temperature characteristics in the charger connector, and the analysis of geometric symmetry in the charging cable and coolant configuration to ensure uniform heat distribution. Key operating conditions were systematically analyzed, including applied currents, ambient temperatures, coolant flow rates, cable core cross-sectional areas, and different types of coolants. Results indicate that increasing the applied current from 400 A to 800 A raised the connector temperature from 60.73 °C to 97.33 °C. As the ambient temperature increased from 20 °C to 50 °C, the connector temperature rose significantly from 42.71 °C to 74.99 °C, while the maximum cable core temperature increased from 65.26 °C to 100.61 °C. Increasing the cable core cross-sectional area from 20 mm2 to 30 mm2 reduced the connector temperature from 77.20 °C to 74.99 °C. Meanwhile, increasing the coolant flow rate from 2 LPM to 5 LPM had a negligible effect on the connector temperature. Among the three tested coolants, Novec 7500 exhibited the highest cooling efficiency, achieving the lowest contact temperature (74.76 °C) and the highest performance evaluation criteria (PEC) value of 3.8. This study provides valuable guidelines for enhancing symmetry-driven thermal management systems and demonstrates the potential of immersion cooling to improve efficiency, safety, and operational reliability in next-generation high-power EV chargers.


  • Open Access

    A Review on Advanced Battery Thermal Management Systems for Fast Charging in Electric Vehicles

    by Le Duc Tai, Kunal Sandip Garud, Seong-Guk Hwang, Moo-Yeon Lee

    To protect the environment and reduce dependence on fossil fuels, the world is shifting towards electric vehicles (EVs) as a sustainable solution. The development of fast charging technologies for EVs to reduce charging time and increase operating range is essential to replace traditional internal combustion engine (ICE) vehicles. Lithium-ion batteries (LIBs) are efficient energy storage systems in EVs. However, the efficiency of LIBs depends significantly on their working temperature range. However, the huge amount of heat generated during fast charging increases battery temperature uncontrollably and may lead to thermal runaway, which poses serious hazards during the operation of EVs. In addition, fast charging with high current accelerates battery aging and seriously reduces battery capacity. Therefore, an effective and advanced battery thermal management system (BTMS) is essential to ensure the performance, lifetime, and safety of LIBs, particularly under extreme charging conditions. In this perspective, the current review presents the state-of-the-art thermal management strategies for LIBs during fast charging. The serious thermal problems owing to heat generated during fast charging and its impacts on LIBs are discussed. The core part of this review presents advanced cooling strategies such as indirect liquid cooling, immersion cooling, and hybrid cooling for the thermal management of batteries during fast charging based on recently published research studies in the period of 2019–2024 (5 years). Finally, the key findings and potential directions for next-generation BTMSs toward fast charging are proposed. This review offers an in-depth analysis by providing recommendations and potential solutions to develop reliable and efficient BTMSs for LIBs during fast charging.


  • Open Access

    Artificial Neural Network Modeling to Predict Thermal and Electrical Performances of Batteries with Direct Oil Cooling

    by Kunal Sandip Garud, Jeong-Woo Han, Seong-Guk Hwang, Moo-Yeon Lee

    The limitations of existing commercial indirect liquid cooling have drawn attention to direct liquid cooling for battery thermal management in next-generation electric vehicles. To commercialize direct liquid cooling for battery thermal management, an extensive database reflecting performance and operating parameters needs to be established. The development of prediction models could generate this reference database to design an effective cooling system with the least experimental effort. In the present work, artificial neural network (ANN) modeling is demonstrated to predict the thermal and electrical performances of batteries with direct oil cooling based on various operating conditions. The experiments are conducted on an 18650 battery module with direct oil cooling to generate the learning data for the development of neural network models. The neural network models are developed considering oil temperature, oil flow rate, and discharge rate as the input operating conditions and maximum temperature, temperature difference, heat transfer coefficient, and voltage as the output thermal and electrical performances. The proposed neural network models comprise two algorithms, the Levenberg–Marquardt (LM) training variant with the Tangential-Sigmoidal (Tan-Sig) transfer function and that with the Logarithmic-Sigmoidal (Log-Sig) transfer function. The ANN_LM-Tan algorithm with a structure of 3-10-10-4 shows accurate prediction of thermal and electrical performances under all operating conditions compared to the ANN_LM-Log algorithm with the same structure. The maximum prediction errors for the ANN_LM-Tan and ANN_LM-Log algorithms are restricted within ±0.97% and ±4.81%, respectively, considering all input and output parameters. The ANN_LM-Tan algorithm is suggested to accurately predict the thermal and electrical performances of batteries with direct oil cooling based on a maximum determination coefficient (R2) and variance coefficient (COV) of 0.99 and 1.65, respectively.


  • Top Cited Papers
    Open Access

    A Review of Advanced Cooling Strategies for Battery Thermal Management Systems in Electric Vehicles

    by Kunal Sandip Garud, Le Duc Tai, Seong-Guk Hwang, Nghia-Huu Nguyen, Moo-Yeon Lee

    Electric vehicles (EVs) offer a potential solution to face the global energy crisis and climate change issues in the transportation sector. Currently, lithium-ion (Li-ion) batteries have gained popularity as a source of energy in EVs, owing to several benefits including higher power density. To compete with internal combustion (IC) engine vehicles, the capacity of Li-ion batteries is continuously increasing to improve the efficiency and reliability of EVs. The performance characteristics and safe operations of Li-ion batteries depend on their operating temperature which demands the effective thermal management of Li-ion batteries. The commercially employed cooling strategies have several obstructions to enable the desired thermal management of high-power density batteries with allowable maximum temperature and symmetrical temperature distribution. The efforts are striving in the direction of searching for advanced cooling strategies which could eliminate the limitations of current cooling strategies and be employed in next-generation battery thermal management systems. The present review summarizes numerous research studies that explore advanced cooling strategies for battery thermal management in EVs. Research studies on phase change material cooling and direct liquid cooling for battery thermal management are comprehensively reviewed over the time period of 2018–2023. This review discusses the various experimental and numerical works executed to date on battery thermal management based on the aforementioned cooling strategies. Considering the practical feasibility and drawbacks of phase change material cooling, the focus of the present review is tilted toward the explanation of current research works on direct liquid cooling as an emerging battery thermal management technique. Direct liquid cooling has the potential to achieve the desired battery performance under normal as well as extreme operating conditions. However, extensive research still needs to be executed to commercialize direct liquid cooling as an advanced battery thermal management technique in EVs. The present review would be referred to as one that gives concrete direction in the search for a suitable advanced cooling strategy for battery thermal management in the next generation of EVs.


  • Open Access

    Numerical Study on Cooling Performance Characteristics of 22 kW Traction Inverter Using MHD Pump-Based Cooling System

    by Seong-Guk Hwang, Yurii Kudriavskyi, Kunal Sandip Garud, Moo-Yeon Lee

    The transportation sector is sharply shifting towards electric vehicles (EVs) to reduce environmental issues and the energy crisis. To enhance the driving range and performance of EVs, the integral parts of EVs are being developed with higher energy densities and compact structures. Traction inverters are one of the important parts of EVs which are continuously updating to higher power densities with smaller sizes. This has led to issues of high heat generation, which causes the performance degradation and failure of traction inverters. Therefore, an efficient cooling strategy needs to be proposed for the effective thermal management of traction inverters in EVs. In the present work, the magnetohydrodynamics (MHD) pump-based cooling system is developed for the thermal management of traction inverter for EVs. The cooling performance of traction inverters is investigated using a MHD pump-based cooling system with water and ferrofluid as coolants. The outlet velocity, inverter maximum temperature, and Nusselt number are numerically simulated as the cooling performance characteristics for various operating conditions of inlet velocity, magnetic field intensity, voltage, and volume fraction of ferrofluid. The coupled numerical model is developed using COMSOL Multiphysics commercial software to simulate the cooling performance of a traction inverter with an MHD pump-based cooling system under various conditions. The MHD pump improves the cooling performance of a traction inverter for ferrofluid cooling over water cooling. The cooling performance of the traction inverter improves with an increase in inlet velocity for both water and ferrofluid cooling. However, with an increase in voltage, magnetic field intensity, and volume fraction, the cooling performance of the traction inverter improves only for ferrofluid cooling. The outlet velocity, inverter maximum temperature and Nusselt number in the case of water cooling are 4.03 mm/s and 7.02 mm/s, 49.65 °C, respectively, whereas that in the case of ferrofluid cooling are 40.96 °C, 15.35, and 18.49, respectively. Further, the cooling performance improves for ferrofluid cooling at a magnetic field intensity of 0.4 T and volume fraction of 10% with outlet velocity, inverter maximum temperature, and Nusselt number approach to 12.08 mm/s, 32 °C and 21.43, respectively.


  • Open Access

    Heat Flow Characteristics of Ferrofluid in Magnetic Field Patterns for Electric Vehicle Power Electronics Cooling

    by Seong-Guk Hwang, Kunal Sandip Garud, Jae-Hyeong Seo, Moo-Yeon Lee

    The ferrofluid is a kind of nanofluid that has magnetization properties in addition to excellent thermophysical properties, which has resulted in an effective performance trend in cooling applications. In the present study, experiments are conducted to investigate the heat flow characteristics of ferrofluid based on thermomagnetic convection under the influence of different magnetic field patterns. The temperature and heat dissipation characteristics are compared for ferrofluid under the influence of no-magnet, I, L, and T magnetic field patterns. The results reveal that the heat gets accumulated within ferrofluid near the heating part in the case of no magnet, whereas the heat flows through ferrofluid under the influence of different magnetic field patterns without any external force. Owing to the thermomagnetic convection characteristic of ferrofluid, the heat dissipates from the heating block and reaches the cooling block by following the path of the I magnetic field pattern. However, in the case of the L and T magnetic field patterns, the thermomagnetic convection characteristic of ferrofluid drives the heat from the heating block to the endpoint location of the pattern instead of the cooling block. The asymmetrical heat dissipation in the case of the L magnetic field pattern and the symmetrical heat dissipation in the case of the T magnetic field pattern are observed following the magnetization path of ferrofluid in the respective cases. The results confirm that the direction of heat flow could be controlled based on the type of magnetic field pattern and its path by utilizing the thermomagnetic behavior of ferrofluid. The proposed lab-scale experimental set-up and results database could be utilized to design an automatic energy transport system for the cooling of power conversion devices in electric vehicles.