Mengxia Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mengxia Zhou has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Wei Yan
Nanjing Normal University
8 shared publications Wei Yan
Department of Electrical Engineering, Nanjing Normal University, Nanjing, China
3 shared publicationsHanqing Duan
2 shared publicationsJiahao Wen
2 shared publicationsShuo Dong
2 shared publicationsTao Zhang
2 shared publications
Latest Publications
- 16 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Admittance-spectrum-based dual-resonance feature prediction and target-oriented design of annular piezoelectric ceramics for conducted EMI suppression
- 16 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Admittance-spectrum-based dual-resonance feature prediction and target-oriented design of annular piezoelectric ceramics for conducted EMI suppression
- Open Access
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
Admittance-Spectrum-Based Dual-Resonance Feature Prediction and Target-Oriented Design of Annular Piezoelectric Ceramics for Conducted EMI Suppression
The capacitance of Y capacitors in EMI filters is constrained by leakage-current requirements, which limits further filter miniaturization. This study presents a dual-resonance feature prediction and target-oriented design method for annular piezoelectric ceramics. By combining measured admittance spectra with finite-element simulations, 1232 geometry-parameterized admittance spectra were constructed, and the frequencies and peak admittances of the first two dominant resonance peaks were extracted as modeling features. Several surrogate models were evaluated using strict nested fivefold cross-validation, and the best-performing model was used for Top-K inverse design targeted at the measured dominant EMI noise frequencies. The selected annular sample was validated through admittance measurements and conducted EMI tests on a flyback converter. Compared with a conventional Y-capacitor scheme, the piezoelectric annular scheme improved the suppression levels at the two target frequencies by 2.81 dB and 5.14 dB, respectively, while reducing the weight and volume of the key passive components by 73.6% and 61.8%, respectively.
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAdmittance-Spectrum-Based Dual-Resonance Feature Prediction and Target-Oriented Design of Annular Piezoelectric Ceramics for Conducted EMI Suppression
The capacitance of Y capacitors in EMI filters is constrained by leakage-current requirements, which limits further filter miniaturization. This study presents a dual-resonance feature prediction and target-oriented design method for annular piezoelectric ceramics. By combining measured admittance spectra with finite-element simulations, 1232 geometry-parameterized admittance spectra were constructed, and the frequencies and peak admittances of the first two dominant resonance peaks were extracted as modeling features. Several surrogate models were evaluated using strict nested fivefold cross-validation, and the best-performing model was used for Top-K inverse design targeted at the measured dominant EMI noise frequencies. The selected annular sample was validated through admittance measurements and conducted EMI tests on a flyback converter. Compared with a conventional Y-capacitor scheme, the piezoelectric annular scheme improved the suppression levels at the two target frequencies by 2.81 dB and 5.14 dB, respectively, while reducing the weight and volume of the key passive components by 73.6% and 61.8%, respectively.
- 30 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (4) , 10057-10065
Electromagnetic Interference Feature Extraction for Permanent Magnet Synchronous Motors Currents Based on Fast Independent Component Analysis
Stator currents in permanent magnet synchronous motor (PMSM) are inevitably affected by electromagnetic interference (EMI) from power devices during operation. This paper presents a novel feature extraction method based on fast independent component analysis (FastICA), where negentropy is selected as the objective function to optimize the three-phase stator currents and obtain separated signals. Then, separated signals are rearranged in the order of spectral width to identify EMI signal, whose amplitude is adjusted using fast iterative shrinkage thresholding algorithm (FISTA). Simulation and experimental results show that the proposed method can eliminate the uncertainty in amplitude and sequence of FastICA, effectively separating EMI noise from the three-phase currents under varied conditions. Compared with digital filtering techniques based on the frequency, the proposed method acquires EMI with the same and neighboring frequencies as the fundamental current, providing more precise interference recognition.
- 30 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (4) , 10057-10065
Electromagnetic Interference Feature Extraction for Permanent Magnet Synchronous Motors Currents Based on Fast Independent Component Analysis
Stator currents in permanent magnet synchronous motor (PMSM) are inevitably affected by electromagnetic interference (EMI) from power devices during operation. This paper presents a novel feature extraction method based on fast independent component analysis (FastICA), where negentropy is selected as the objective function to optimize the three-phase stator currents and obtain separated signals. Then, separated signals are rearranged in the order of spectral width to identify EMI signal, whose amplitude is adjusted using fast iterative shrinkage thresholding algorithm (FISTA). Simulation and experimental results show that the proposed method can eliminate the uncertainty in amplitude and sequence of FastICA, effectively separating EMI noise from the three-phase currents under varied conditions. Compared with digital filtering techniques based on the frequency, the proposed method acquires EMI with the same and neighboring frequencies as the fundamental current, providing more precise interference recognition.
- 13 June 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (2) , 459-467
Impedance modeling and parameter extraction of elastically crimped IGBT devices based on differential evolution
- 13 June 2025
- Published by Springer Nature in Journal of Power Electronics
- Vol. 26 (2) , 459-467
Impedance modeling and parameter extraction of elastically crimped IGBT devices based on differential evolution
- Open Access
- 15 April 2025
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 66
Modeling and performance evaluation of filtering components for switch-mode power supplies based on piezoelectric effect
- 15 April 2025
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 66
Open AccessModeling and performance evaluation of filtering components for switch-mode power supplies based on piezoelectric effect
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Modeling and Measurement of Conducted EMI Suppression Elements for Switch-Mode Power Supplies Based on the Inverse Piezoelectric Effect
To suppress interference peaks in the low-frequency range of switch-mode power supplies (SMPSs), passive electromagnetic interference (EMI) filters typically require the use of common-mode inductors with higher inductance values. This results in an increase in the volume and weight of SMPSs, as well as a decrease in their efficiency. Therefore, this paper proposes a method for modeling and measurement of conducted EMI suppression elements for SMPSs based on the inverse piezoelectric effect. When piezoelectric ceramics undergo the inverse piezoelectric effect, they vibrate in different modes and generate multiple resonances. At the resonance frequencies, piezoelectric ceramics can provide low-impedance propagation paths for conducted EMI, thereby leading to the attenuation of discrete interference peaks. This paper establishes a model between the resonance frequencies and the dimensions under multiple vibration modes of piezoelectric ceramics, based on their equivalent electrical circuits and resonance properties. The established model enables the synergistic design of resonance frequencies for multiple vibration modes by altering the dimensions of piezoelectric ceramics, thereby achieving significant attenuation of interference peaks at multiple specific frequencies in SMPSs. According to the measurement results, under the same EMI standard, using the piezoelectric ceramics to replace the Y-capacitors as a conducted EMI suppression element in the passive EMI filter can reduce the volume of the common-mode inductor by 88% and its weight by 83%, thereby lowering the cost of the SMPS and improving its efficiency.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Modeling and Measurement of Conducted EMI Suppression Elements for Switch-Mode Power Supplies Based on the Inverse Piezoelectric Effect
To suppress interference peaks in the low-frequency range of switch-mode power supplies (SMPSs), passive electromagnetic interference (EMI) filters typically require the use of common-mode inductors with higher inductance values. This results in an increase in the volume and weight of SMPSs, as well as a decrease in their efficiency. Therefore, this paper proposes a method for modeling and measurement of conducted EMI suppression elements for SMPSs based on the inverse piezoelectric effect. When piezoelectric ceramics undergo the inverse piezoelectric effect, they vibrate in different modes and generate multiple resonances. At the resonance frequencies, piezoelectric ceramics can provide low-impedance propagation paths for conducted EMI, thereby leading to the attenuation of discrete interference peaks. This paper establishes a model between the resonance frequencies and the dimensions under multiple vibration modes of piezoelectric ceramics, based on their equivalent electrical circuits and resonance properties. The established model enables the synergistic design of resonance frequencies for multiple vibration modes by altering the dimensions of piezoelectric ceramics, thereby achieving significant attenuation of interference peaks at multiple specific frequencies in SMPSs. According to the measurement results, under the same EMI standard, using the piezoelectric ceramics to replace the Y-capacitors as a conducted EMI suppression element in the passive EMI filter can reduce the volume of the common-mode inductor by 88% and its weight by 83%, thereby lowering the cost of the SMPS and improving its efficiency.
- 6 November 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (5) , 859-867
Differential evolution and common-mode current-based modeling of permanent magnet synchronous motors
- 6 November 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (5) , 859-867
Differential evolution and common-mode current-based modeling of permanent magnet synchronous motors
- Open Access
- 25 August 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2326-2339
Resilient robust model predictive load frequency control for smart grids with air conditioning loads
This paper investigates the robust model predictive load frequency control problem for smart grids with wind power under cyber attacks. To accommodate intermittent power generation, the demand response of the system is considered by involving the air conditioning loads in the frequency regulation. In addition, the system uncertainties produced by the air conditioning load users and wind turbines when replacing traditional generator sets are considered. By using the cone complementary linearization algorithm and the linear matrix inequality technique, a resilience robust model predictive control strategy with mixed performance indexes is proposed. Furthermore, a rigorous derivation of the recursive feasibility of robust model predictive control is given. Finally, the simulation results of the two‐area load frequency control scheme show that the proposed model predictive control strategy is capable of realizing the load frequency control of the multi‐area smart grid and is robust to the parameter uncertainties and frequency regulation of the system. The results also show that the proposed model predictive control strategy has some resistance to cyber attacks and external disturbances.
- 25 August 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2326-2339
Open AccessResilient robust model predictive load frequency control for smart grids with air conditioning loads
This paper investigates the robust model predictive load frequency control problem for smart grids with wind power under cyber attacks. To accommodate intermittent power generation, the demand response of the system is considered by involving the air conditioning loads in the frequency regulation. In addition, the system uncertainties produced by the air conditioning load users and wind turbines when replacing traditional generator sets are considered. By using the cone complementary linearization algorithm and the linear matrix inequality technique, a resilience robust model predictive control strategy with mixed performance indexes is proposed. Furthermore, a rigorous derivation of the recursive feasibility of robust model predictive control is given. Finally, the simulation results of the two‐area load frequency control scheme show that the proposed model predictive control strategy is capable of realizing the load frequency control of the multi‐area smart grid and is robust to the parameter uncertainties and frequency regulation of the system. The results also show that the proposed model predictive control strategy has some resistance to cyber attacks and external disturbances.
- Open Access
- 31 January 2024
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 39 (1) , 81-90
Research on the Prediction Method of Conducted Interference in Flyback Converters based on the High-frequency Transformer Model
Conducted electromagnetic interference (EMI) has always been a challenge for designers of switched-mode power supplies. Flyback converters are used in various applications. However, as the switching frequency of these converters increases, the issue of electromagnetic interference becomes progressively more severe. In light of this, this paper presents a predictive method for conducted interference in flyback converters, based on a high-frequency transformer model. A high-frequency transformer model topology is proposed, integrating traditional inductance models with a three-capacitor model. Subsequently, a self-organizing migrating algorithm (SOMA) is employed for the extraction of parameters from the high-frequency transformer model, and a high-frequency model is established for a transformer. Finally, the high-frequency model is applied to the prediction of conducted interference in flyback converters. The results demonstrate that the proposed predictive method can effectively forecast the actual conducted interference, thereby providing a reference for suppression of conducted electromagnetic interference.
- 31 January 2024
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 39 (1) , 81-90
Open AccessResearch on the Prediction Method of Conducted Interference in Flyback Converters based on the High-frequency Transformer Model
Conducted electromagnetic interference (EMI) has always been a challenge for designers of switched-mode power supplies. Flyback converters are used in various applications. However, as the switching frequency of these converters increases, the issue of electromagnetic interference becomes progressively more severe. In light of this, this paper presents a predictive method for conducted interference in flyback converters, based on a high-frequency transformer model. A high-frequency transformer model topology is proposed, integrating traditional inductance models with a three-capacitor model. Subsequently, a self-organizing migrating algorithm (SOMA) is employed for the extraction of parameters from the high-frequency transformer model, and a high-frequency model is established for a transformer. Finally, the high-frequency model is applied to the prediction of conducted interference in flyback converters. The results demonstrate that the proposed predictive method can effectively forecast the actual conducted interference, thereby providing a reference for suppression of conducted electromagnetic interference.