Francesca De Ridder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesca De Ridder has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Christophe De Block
Faculty of Medicine and Health Sciences, Endocrinology-Diabetology, Antwerp University Hospital and University of Antwerp , 2650 Edegem
2 shared publications Danaë Delbeke
Indigo Diabetes N.V., Ghent, Belgium
2 shared publicationsRie Braspenning
Department of Endocrinology-Diabetology-Metabolism, Antwerp University Hospital, Antwerp, Belgium
2 shared publications- Benedicte Y. De Winter
Laboratory of Experimental Medicine and Pediatrics and Infla-Med Centre of Excellence, University of Antwerp, Antwerp, Belgium
1 shared publication - Dirk Vissers
University of Antwerp
1 shared publication - Eric Renard
Institute of Functional Genomics, University of Montpellier, CNRS, INSERM, Montpellier, France
1 shared publication
Latest Publications
- Open Access
- 3 May 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (5) , e0301041
Early feasibility study with an implantable near-infrared spectroscopy sensor for glucose, ketones, lactate and ethanol
Objective: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. Research design and methods: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40–400 mg/dL, 2.2–22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4–8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. Results: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. Conclusions: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. Trial registration: Clinical trial identifier: NCT04782934.
- 3 May 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (5) , e0301041
Open AccessEarly feasibility study with an implantable near-infrared spectroscopy sensor for glucose, ketones, lactate and ethanol
Objective: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. Research design and methods: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40–400 mg/dL, 2.2–22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4–8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. Results: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. Conclusions: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. Trial registration: Clinical trial identifier: NCT04782934.
- 21 May 2022
- Published by Wiley in Diabetes/Metabolism Research and Reviews
- Vol. 38 (6) , e3537
Trends of glucose, lactate and ketones during anaerobic and aerobic exercise in subjects with type 1 diabetes: The ACTION‐1 study
Background: Exercise is part of type 1 diabetes (T1D) management due to its cardiovascular and metabolic benefits. However, despite using continuous glucose monitoring, many patients are reluctant to exercise because of fear for hypoglycaemia.Aims: We assessed trends in glucose, lactate and ketones during anaerobic and aerobic exercise in people with T1D and compared incremental area under the curve (AUC) between both exercises.Methods: Twenty‐one men with T1D (median [IQR]: age 29 years [28–38], body mass index (BMI) 24.4 kg/m2 [22.3–24.9], HbA1c 7.2% [6.7–7.8]), completed a cardiopulmonary exercise test (CPET) and a 60‐min aerobic exercise (AEX) at 60% VO2peak on an ergometer bicycle within a 6‐week period. Subjects consumed a standardised breakfast (6 kcal/kg, 20.2 g CHO/100 ml) before exercise without pre‐meal insulin and basal insulin for pump users.Results: During CPET, glucose levels increased, peaking at 331 mg/dl [257–392] 1–3 h after exercise and reaching a nadir 6 h after exercise at 176 mg/dl [118–217]. Lactate levels peaked at 6.0 mmol/L [5.0–6.6] (max 13.5 mmol/L). During AEX, glucose levels also increased, peaking at 305 mg/dl [245–336] 80 min after exercise and reaching a nadir 6 h after exercise at 211 mg/dl [116–222]. Lactate levels rose quickly to a median of 4.3 mmol/L [2.7–6.7] after 10 min. Ketone levels were low during both tests (median ≤ 0.2 mmol/L). Lactate, but not glucose or ketone AUC, was significantly higher in CPET compared to AEX (p = 0.04).Conclusions: Omitting pre‐meal insulin and also basal insulin in pump users, did prevent hypoglycaemia but induced hyperglycaemia due to a too high carbohydrate ingestion. No ketosis was recorded during or after the exercises.Clinical Trial Registration: ClinicalTrials.gov: NCT05097339
- 21 May 2022
- Published by Wiley in Diabetes/Metabolism Research and Reviews
- Vol. 38 (6) , e3537
Trends of glucose, lactate and ketones during anaerobic and aerobic exercise in subjects with type 1 diabetes: The ACTION‐1 study
Background: Exercise is part of type 1 diabetes (T1D) management due to its cardiovascular and metabolic benefits. However, despite using continuous glucose monitoring, many patients are reluctant to exercise because of fear for hypoglycaemia.Aims: We assessed trends in glucose, lactate and ketones during anaerobic and aerobic exercise in people with T1D and compared incremental area under the curve (AUC) between both exercises.Methods: Twenty‐one men with T1D (median [IQR]: age 29 years [28–38], body mass index (BMI) 24.4 kg/m2 [22.3–24.9], HbA1c 7.2% [6.7–7.8]), completed a cardiopulmonary exercise test (CPET) and a 60‐min aerobic exercise (AEX) at 60% VO2peak on an ergometer bicycle within a 6‐week period. Subjects consumed a standardised breakfast (6 kcal/kg, 20.2 g CHO/100 ml) before exercise without pre‐meal insulin and basal insulin for pump users.Results: During CPET, glucose levels increased, peaking at 331 mg/dl [257–392] 1–3 h after exercise and reaching a nadir 6 h after exercise at 176 mg/dl [118–217]. Lactate levels peaked at 6.0 mmol/L [5.0–6.6] (max 13.5 mmol/L). During AEX, glucose levels also increased, peaking at 305 mg/dl [245–336] 80 min after exercise and reaching a nadir 6 h after exercise at 211 mg/dl [116–222]. Lactate levels rose quickly to a median of 4.3 mmol/L [2.7–6.7] after 10 min. Ketone levels were low during both tests (median ≤ 0.2 mmol/L). Lactate, but not glucose or ketone AUC, was significantly higher in CPET compared to AEX (p = 0.04).Conclusions: Omitting pre‐meal insulin and also basal insulin in pump users, did prevent hypoglycaemia but induced hyperglycaemia due to a too high carbohydrate ingestion. No ketosis was recorded during or after the exercises.Clinical Trial Registration: ClinicalTrials.gov: NCT05097339