Kyung Min Nam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kyung Min Nam has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Dennis W. J. Klomp
Center for Image Sciences, High Field MR Research Group, Department of Radiology University Medical Centre Utrecht Utrecht The Netherlands
4 shared publications- Alex A. Bhogal
Department of Radiology, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publications - Arjan D. Hendriks
Department of Radiology and Nuclear Medicine, Imaging and Oncology Division, University Medical Center Utrecht, Utrecht, the Netherlands.
3 shared publications Jannie P. Wijnen
Center for Image Sciences, High Field MR Research Group, Department of Radiology University Medical Centre Utrecht Utrecht The Netherlands
3 shared publicationsAlex A. Bhogal
Center for Image Sciences, High Field MR Research Group, Department of Radiology University Medical Centre Utrecht Utrecht The Netherlands
2 shared publicationsAyhan Gursan
Center for Image Sciences, High Field MR Research Group, Department of Radiology University Medical Centre Utrecht Utrecht The Netherlands
2 shared publications
Latest Publications
- Open Access
- 3 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1946-1962
pTx‐Pulseq in hybrid sequences: Accessible and advanced hybrid open‐source MRI sequences on Philips scanners
Purpose: To enhance the accessibility of advanced pulse sequences, or parts thereof, through the open‐source Pulseq framework. This work extends the Pulseq framework to Philips MRI systems and incorporates dynamic parallel‐transmit (pTx) capabilities within the constraints of the existing Pulseq format. This enables the hybrid use of Pulseq sequences within the native vendor's scans, leveraging the combined strengths of both approaches. We showcase a new possibility of these techniques: the use of a portable cross‐vendor universal pulse (UP) excitation in a native scan.Methods: pTx‐Pulseq was implemented to add full dynamic pTx within the Pulseq specification. We developed a Pulseq interpreter for Philips systems, supporting both Pulseq‐only and hybrid sequences. The hybrid mode was used to integrate a UP from the PASTeUR package into a vendor's native scan. Simulation experiments, safety validations, field measurements, and imaging experiments in phantom and in vivo were conducted to verify the interpreter's and UP's functionality.Results: The interpreter executed Pulseq sequences on a Philips 7T system, accurately reproducing gradient waveforms and dynamic pTx sequences. The real‐time safety systems operated correctly. Phantom and in vivo scans demonstrated comparable image quality to native sequences, validating the effectiveness of the interpreter and the successful cross‐vendor use of universal pulses.Conclusion: The successful cross‐vendor application of a universal pulse through pTx‐Pulseq in a hybrid sequence demonstrates how advanced MRI techniques can be made accessible. This not only highlights the flexibility and extensibility of Pulseq but also sets the stage for rapid clinical translation of innovative imaging techniques.
- 3 July 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1946-1962
Open AccesspTx‐Pulseq in hybrid sequences: Accessible and advanced hybrid open‐source MRI sequences on Philips scanners
Purpose: To enhance the accessibility of advanced pulse sequences, or parts thereof, through the open‐source Pulseq framework. This work extends the Pulseq framework to Philips MRI systems and incorporates dynamic parallel‐transmit (pTx) capabilities within the constraints of the existing Pulseq format. This enables the hybrid use of Pulseq sequences within the native vendor's scans, leveraging the combined strengths of both approaches. We showcase a new possibility of these techniques: the use of a portable cross‐vendor universal pulse (UP) excitation in a native scan.Methods: pTx‐Pulseq was implemented to add full dynamic pTx within the Pulseq specification. We developed a Pulseq interpreter for Philips systems, supporting both Pulseq‐only and hybrid sequences. The hybrid mode was used to integrate a UP from the PASTeUR package into a vendor's native scan. Simulation experiments, safety validations, field measurements, and imaging experiments in phantom and in vivo were conducted to verify the interpreter's and UP's functionality.Results: The interpreter executed Pulseq sequences on a Philips 7T system, accurately reproducing gradient waveforms and dynamic pTx sequences. The real‐time safety systems operated correctly. Phantom and in vivo scans demonstrated comparable image quality to native sequences, validating the effectiveness of the interpreter and the successful cross‐vendor use of universal pulses.Conclusion: The successful cross‐vendor application of a universal pulse through pTx‐Pulseq in a hybrid sequence demonstrates how advanced MRI techniques can be made accessible. This not only highlights the flexibility and extensibility of Pulseq but also sets the stage for rapid clinical translation of innovative imaging techniques.
- Open Access
- 27 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6)
WAND: Wavelet Analysis‐Based Neural Decomposition of MRS Signals for Artifact Removal
Accurate quantification of metabolites in magnetic resonance spectroscopy (MRS) is challenged by low signal‐to‐noise ratio (SNR), overlapping metabolites, and various artifacts. Particularly, unknown and unparameterized baseline effects obscure the quantification of low‐concentration metabolites, limiting MRS reliability. This paper introduces wavelet analysis‐based neural decomposition (WAND), a novel data‐driven method designed to decompose MRS signals into their constituent components: metabolite‐specific signals, baseline, and artifacts. WAND takes advantage of the enhanced separability of these components within the wavelet domain. The method employs a neural network, specifically a U‐Net architecture, trained to predict masks for wavelet coefficients obtained through the continuous wavelet transform. These masks effectively isolate desired signal components in the wavelet domain, which are then inverse‐transformed to obtain separated signals. Notably, an artifact mask is created by inverting the sum of all known signal masks, enabling WAND to capture and remove even unpredictable artifacts. The effectiveness of WAND in achieving accurate decomposition is demonstrated through numerical evaluations using simulated spectra. Furthermore, WAND's artifact removal capabilities significantly enhance the quantification accuracy of linear combination model fitting. The method's robustness is further validated using data from the 2016 MRS Fitting Challenge and in vivo experiments.
- 27 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6)
Open AccessWAND: Wavelet Analysis‐Based Neural Decomposition of MRS Signals for Artifact Removal
Accurate quantification of metabolites in magnetic resonance spectroscopy (MRS) is challenged by low signal‐to‐noise ratio (SNR), overlapping metabolites, and various artifacts. Particularly, unknown and unparameterized baseline effects obscure the quantification of low‐concentration metabolites, limiting MRS reliability. This paper introduces wavelet analysis‐based neural decomposition (WAND), a novel data‐driven method designed to decompose MRS signals into their constituent components: metabolite‐specific signals, baseline, and artifacts. WAND takes advantage of the enhanced separability of these components within the wavelet domain. The method employs a neural network, specifically a U‐Net architecture, trained to predict masks for wavelet coefficients obtained through the continuous wavelet transform. These masks effectively isolate desired signal components in the wavelet domain, which are then inverse‐transformed to obtain separated signals. Notably, an artifact mask is created by inverting the sum of all known signal masks, enabling WAND to capture and remove even unpredictable artifacts. The effectiveness of WAND in achieving accurate decomposition is demonstrated through numerical evaluations using simulated spectra. Furthermore, WAND's artifact removal capabilities significantly enhance the quantification accuracy of linear combination model fitting. The method's robustness is further validated using data from the 2016 MRS Fitting Challenge and in vivo experiments.
- Open Access
- 22 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1860-1873
3D deuterium metabolic imaging (DMI) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction
Purpose: To implement a low‐rank and subspace model‐based reconstruction for 3D deuterium metabolic imaging (DMI) and compare its performance against Fourier transform‐based (FFT) reconstruction in terms of spectral fitting reliability.Methods: Both reconstruction methods were applied on simulated and experimental DMI data. Numerical simulations were performed to evaluate the effect of increasing acceleration factors. The impact on spectral fitting results, SNR, and the overall normalized root mean square error (NRMSE) compared to ground‐truth data were calculated. A comparative analysis was performed on DMI data acquired from the human liver, including both natural abundance and post‐deuterated glucose intake data at 7 T.Results: Simulation showed the Cramer‐Rao lower bound [%] of water, glucose, sum of glutamate and glutamine (Glx), and lipid signals for the low‐rank and subspace model‐based reconstruction at R = 1.0 was 12.4, 14.7, 17.3, and 11.0 times lower than FFT. At R = 1.1, NRMSE was 1.4%, 1.3%, 0.8%, and 4.2% lower for the water, glucose, Glx, and lipid, respectively, compared to FFT. However, the NRMSE of the Glx and lipid increased by 0.4% and 3.2% at R = 1.3. For the in vivo DMI experiment, SNR was 2.5–3.0 times higher compared to FFT. The fitted amplitude of water and glucose peaks showed Cramer‐Rao lower bound [%] values that were approximately 2.3 times lower than FFT.Conclusion: Simulations and in vivo experiments on the human liver demonstrate that low‐rank and subspace model‐based reconstruction with undersampled data mitigates noise and enhances spectral fitting quality.
- 22 December 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (5) , 1860-1873
Open Access3D deuterium metabolic imaging (DMI) of the human liver at 7 T using low‐rank and subspace model‐based reconstruction
Purpose: To implement a low‐rank and subspace model‐based reconstruction for 3D deuterium metabolic imaging (DMI) and compare its performance against Fourier transform‐based (FFT) reconstruction in terms of spectral fitting reliability.Methods: Both reconstruction methods were applied on simulated and experimental DMI data. Numerical simulations were performed to evaluate the effect of increasing acceleration factors. The impact on spectral fitting results, SNR, and the overall normalized root mean square error (NRMSE) compared to ground‐truth data were calculated. A comparative analysis was performed on DMI data acquired from the human liver, including both natural abundance and post‐deuterated glucose intake data at 7 T.Results: Simulation showed the Cramer‐Rao lower bound [%] of water, glucose, sum of glutamate and glutamine (Glx), and lipid signals for the low‐rank and subspace model‐based reconstruction at R = 1.0 was 12.4, 14.7, 17.3, and 11.0 times lower than FFT. At R = 1.1, NRMSE was 1.4%, 1.3%, 0.8%, and 4.2% lower for the water, glucose, Glx, and lipid, respectively, compared to FFT. However, the NRMSE of the Glx and lipid increased by 0.4% and 3.2% at R = 1.3. For the in vivo DMI experiment, SNR was 2.5–3.0 times higher compared to FFT. The fitted amplitude of water and glucose peaks showed Cramer‐Rao lower bound [%] values that were approximately 2.3 times lower than FFT.Conclusion: Simulations and in vivo experiments on the human liver demonstrate that low‐rank and subspace model‐based reconstruction with undersampled data mitigates noise and enhances spectral fitting quality.
- Open Access
- 20 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1170
Improving Brain Metabolite Detection with a Combined Low-Rank Approximation and Denoising Diffusion Probabilistic Model Approach
In vivo proton magnetic resonance spectroscopy (MRS) is a noninvasive technique for monitoring brain metabolites. However, it is challenged by a low signal-to-noise ratio (SNR), often necessitating extended scan times to compensate. One of the conventional techniques for noise reduction is signal averaging, which is inherently time-consuming and can lead to participant discomfort, thus posing limitations in clinical settings. This study aimed to develop a hybrid denoising strategy that integrates low-rank approximation and denoising diffusion probabilistic model (DDPM) to enhance MRS data quality and shorten scan times. Using publicly available 1H MRS datasets from 15 subjects, we applied the Casorati SVD and DDPM to obtain baseline and functional data during a pain stimulation task. This method significantly improved SNR, resulting in outcomes comparable to or better than averaging over 32 signals. It also provided the most consistent metabolite measurements and adequately tracked temporal changes in glutamate levels, correlating with pain intensity ratings after heating. These findings demonstrate that our approach enhances MRS data quality, offering a more efficient alternative to conventional methods and expanding the potential for the real-time monitoring of neurochemical changes. This contribution has the potential to advance MRS techniques by integrating advanced denoising methods to increase the acquisition speed and enhance the precision of brain metabolite analyses.
- 20 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1170
Open AccessImproving Brain Metabolite Detection with a Combined Low-Rank Approximation and Denoising Diffusion Probabilistic Model Approach
In vivo proton magnetic resonance spectroscopy (MRS) is a noninvasive technique for monitoring brain metabolites. However, it is challenged by a low signal-to-noise ratio (SNR), often necessitating extended scan times to compensate. One of the conventional techniques for noise reduction is signal averaging, which is inherently time-consuming and can lead to participant discomfort, thus posing limitations in clinical settings. This study aimed to develop a hybrid denoising strategy that integrates low-rank approximation and denoising diffusion probabilistic model (DDPM) to enhance MRS data quality and shorten scan times. Using publicly available 1H MRS datasets from 15 subjects, we applied the Casorati SVD and DDPM to obtain baseline and functional data during a pain stimulation task. This method significantly improved SNR, resulting in outcomes comparable to or better than averaging over 32 signals. It also provided the most consistent metabolite measurements and adequately tracked temporal changes in glutamate levels, correlating with pain intensity ratings after heating. These findings demonstrate that our approach enhances MRS data quality, offering a more efficient alternative to conventional methods and expanding the potential for the real-time monitoring of neurochemical changes. This contribution has the potential to advance MRS techniques by integrating advanced denoising methods to increase the acquisition speed and enhance the precision of brain metabolite analyses.
- Open Access
- 11 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2247-2256
A silent echo‐planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis
PurposeWe present a novel silent echo-planar spectroscopic imaging (EPSI) readout, which uses an ultrasonic gradient insert to accelerate MRSI while producing a high spectral bandwidth (20 kHz) and a low sound level.MethodsThe ultrasonic gradient insert consisted of a single-axis (z-direction) plug-and-play gradient coil, powered by an audio amplifier, and produced 40 mT/m at 20 kHz. The silent EPSI readout was implemented in a phase-encoded MRSI acquisition. Here, the additional spatial encoding provided by this silent EPSI readout was used to reduce the number of phase-encoding steps. Spectroscopic acquisitions using phase-encoded MRSI, a conventional EPSI-readout, and the silent EPSI readout were performed on a phantom containing metabolites with resonance frequencies in the ppm range of brain metabolites (0-4 ppm). These acquisitions were used to determine sound levels, showcase the high spectral bandwidth of the silent EPSI readout, and determine the SNR efficiency and the scan efficiency.ResultsThe silent EPSI readout featured a 19-dB lower sound level than a conventional EPSI readout while featuring a high spectral bandwidth of 20 kHz without spectral ghosting artifacts. Compared with phase-encoded MRSI, the silent EPSI readout provided a 4.5-fold reduction in scan time. In addition, the scan efficiency of the silent EPSI readout was higher (82.5% vs. 51.5%) than the conventional EPSI readout.ConclusionsWe have for the first time demonstrated a silent spectroscopic imaging readout with a high spectral bandwidth and low sound level. This sound reduction provided by the silent readout is expected to have applications in sound-sensitive patient groups, whereas the high spectral bandwidth could benefit ultrahigh-field MR systems.
- 11 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2247-2256
Open AccessA silent echo‐planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis
PurposeWe present a novel silent echo-planar spectroscopic imaging (EPSI) readout, which uses an ultrasonic gradient insert to accelerate MRSI while producing a high spectral bandwidth (20 kHz) and a low sound level.MethodsThe ultrasonic gradient insert consisted of a single-axis (z-direction) plug-and-play gradient coil, powered by an audio amplifier, and produced 40 mT/m at 20 kHz. The silent EPSI readout was implemented in a phase-encoded MRSI acquisition. Here, the additional spatial encoding provided by this silent EPSI readout was used to reduce the number of phase-encoding steps. Spectroscopic acquisitions using phase-encoded MRSI, a conventional EPSI-readout, and the silent EPSI readout were performed on a phantom containing metabolites with resonance frequencies in the ppm range of brain metabolites (0-4 ppm). These acquisitions were used to determine sound levels, showcase the high spectral bandwidth of the silent EPSI readout, and determine the SNR efficiency and the scan efficiency.ResultsThe silent EPSI readout featured a 19-dB lower sound level than a conventional EPSI readout while featuring a high spectral bandwidth of 20 kHz without spectral ghosting artifacts. Compared with phase-encoded MRSI, the silent EPSI readout provided a 4.5-fold reduction in scan time. In addition, the scan efficiency of the silent EPSI readout was higher (82.5% vs. 51.5%) than the conventional EPSI readout.ConclusionsWe have for the first time demonstrated a silent spectroscopic imaging readout with a high spectral bandwidth and low sound level. This sound reduction provided by the silent readout is expected to have applications in sound-sensitive patient groups, whereas the high spectral bandwidth could benefit ultrahigh-field MR systems.
- Open Access
- 8 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (3) , 863-874
Deuterium echo‐planar spectroscopic imaging (EPSI) in the human liver in vivo at 7 T
Purpose: To demonstrate the feasibility of deuterium echo‐planar spectroscopic imaging (EPSI) to accelerate 3D deuterium metabolic imaging in the human liver at 7 T.Methods: A deuterium EPSI sequence, featuring a Hamming‐weighted k‐space acquisition pattern for the phase‐encoding directions, was implemented. Three‐dimensional deuterium EPSI and conventional MRSI were performed on a water/acetone phantom and in vivo in the human liver at natural abundance. Moreover, in vivo deuterium EPSI measurements were acquired after oral administration of deuterated glucose. The effect of acquisition time on SNR was evaluated by retrospectively reducing the number of averages.Results: The SNR of natural abundance deuterated water signal in deuterium EPSI was 6.5% and 5.9% lower than that of MRSI in the phantom and in vivo experiments, respectively. In return, the acquisition time of in vivo EPSI data could be reduced retrospectively to 2 min, beyond the minimal acquisition time of conventional MRSI (of 20 min in this case), while still leaving sufficient SNR. Three‐dimensional deuterium EPSI, after administration of deuterated glucose, enabled monitoring of hepatic glucose dynamics with full liver coverage, a spatial resolution of 20 mm isotropic, and a temporal resolution of 9 min 50 s, which could retrospectively be shortened to 2 min.Conclusion: In this work, we demonstrate the feasibility of accelerated 3D deuterium metabolic imaging of the human liver using deuterium EPSI. The acceleration obtained with EPSI can be used to increase temporal and/or spatial resolution, which will be valuable to study tissue metabolism of deuterated compounds over time.
- 8 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (3) , 863-874
Open AccessDeuterium echo‐planar spectroscopic imaging (EPSI) in the human liver in vivo at 7 T
Purpose: To demonstrate the feasibility of deuterium echo‐planar spectroscopic imaging (EPSI) to accelerate 3D deuterium metabolic imaging in the human liver at 7 T.Methods: A deuterium EPSI sequence, featuring a Hamming‐weighted k‐space acquisition pattern for the phase‐encoding directions, was implemented. Three‐dimensional deuterium EPSI and conventional MRSI were performed on a water/acetone phantom and in vivo in the human liver at natural abundance. Moreover, in vivo deuterium EPSI measurements were acquired after oral administration of deuterated glucose. The effect of acquisition time on SNR was evaluated by retrospectively reducing the number of averages.Results: The SNR of natural abundance deuterated water signal in deuterium EPSI was 6.5% and 5.9% lower than that of MRSI in the phantom and in vivo experiments, respectively. In return, the acquisition time of in vivo EPSI data could be reduced retrospectively to 2 min, beyond the minimal acquisition time of conventional MRSI (of 20 min in this case), while still leaving sufficient SNR. Three‐dimensional deuterium EPSI, after administration of deuterated glucose, enabled monitoring of hepatic glucose dynamics with full liver coverage, a spatial resolution of 20 mm isotropic, and a temporal resolution of 9 min 50 s, which could retrospectively be shortened to 2 min.Conclusion: In this work, we demonstrate the feasibility of accelerated 3D deuterium metabolic imaging of the human liver using deuterium EPSI. The acceleration obtained with EPSI can be used to increase temporal and/or spatial resolution, which will be valuable to study tissue metabolism of deuterated compounds over time.
- Open Access
- 26 May 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (10) , e4771
Proton metabolic mapping of the brain at 7 T using a two‐dimensional free induction decay–echo‐planar spectroscopic imaging readout with lipid suppression
The increased signal‐to‐noise ratio (SNR) and chemical shift dispersion at high magnetic fields (≥7 T) have enabled neuro‐metabolic imaging at high spatial resolutions. To avoid very long acquisition times with conventional magnetic resonance spectroscopic imaging (MRSI) phase‐encoding schemes, solutions such as pulse‐acquire or free induction decay (FID) sequences with short repetition time and inner volume selection methods with acceleration (echo‐planar spectroscopic imaging [EPSI]), have been proposed. With the inner volume selection methods, limited spatial coverage of the brain and long echo times may still impede clinical implementation. FID‐MRSI sequences benefit from a short echo time and have a high SNR per time unit; however, contamination from strong extra‐cranial lipid signals remains a problem that can hinder correct metabolite quantification. L2‐regularization can be applied to remove lipid signals in cases with high spatial resolution and accurate prior knowledge. In this work, we developed an accelerated two‐dimensional (2D) FID‐MRSI sequence using an echo‐planar readout and investigated the performance of lipid suppression by L2‐regularization, an external crusher coil, and the combination of these two methods to compare the resulting spectral quality in three subjects. The reduction factor of lipid suppression using the crusher coil alone varies from 2 to 7 in the lipid region of the brain boundary. For the combination of the two methods, the average lipid area inside the brain was reduced by 2% to 38% compared with that of unsuppressed lipids, depending on the subject's region of interest. 2D FID‐EPSI with external lipid crushing and L2‐regularization provides high in‐plane coverage and is suitable for investigating brain metabolite distributions at high fields.
- 26 May 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (10) , e4771
Open AccessProton metabolic mapping of the brain at 7 T using a two‐dimensional free induction decay–echo‐planar spectroscopic imaging readout with lipid suppression
The increased signal‐to‐noise ratio (SNR) and chemical shift dispersion at high magnetic fields (≥7 T) have enabled neuro‐metabolic imaging at high spatial resolutions. To avoid very long acquisition times with conventional magnetic resonance spectroscopic imaging (MRSI) phase‐encoding schemes, solutions such as pulse‐acquire or free induction decay (FID) sequences with short repetition time and inner volume selection methods with acceleration (echo‐planar spectroscopic imaging [EPSI]), have been proposed. With the inner volume selection methods, limited spatial coverage of the brain and long echo times may still impede clinical implementation. FID‐MRSI sequences benefit from a short echo time and have a high SNR per time unit; however, contamination from strong extra‐cranial lipid signals remains a problem that can hinder correct metabolite quantification. L2‐regularization can be applied to remove lipid signals in cases with high spatial resolution and accurate prior knowledge. In this work, we developed an accelerated two‐dimensional (2D) FID‐MRSI sequence using an echo‐planar readout and investigated the performance of lipid suppression by L2‐regularization, an external crusher coil, and the combination of these two methods to compare the resulting spectral quality in three subjects. The reduction factor of lipid suppression using the crusher coil alone varies from 2 to 7 in the lipid region of the brain boundary. For the combination of the two methods, the average lipid area inside the brain was reduced by 2% to 38% compared with that of unsuppressed lipids, depending on the subject's region of interest. 2D FID‐EPSI with external lipid crushing and L2‐regularization provides high in‐plane coverage and is suitable for investigating brain metabolite distributions at high fields.