Muntathir I. AlBeladi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muntathir I. AlBeladi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Talal A. Aljohani
Materials Science Research Institute, King Abdulaziz City for Science and Technology (KACST), Riyadh 12354, Saudi Arabia
2 shared publications - Abdulrahman I. Alateyah
Department of Mechanical Engineering, College of Engineering, Qassim University, Buraydah, Saudi Arabia
1 shared publication - Fuad Khoshnaw
School of Engineering, Infrastructure and Sustainability, De Montfort University, Leicester LE1 9BH, UK
1 shared publication - Ghaidaa Yajizi
Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
1 shared publication - Khalid N. Alharbi
Nuclear Technologies Institute (NTI), King Abdulaziz City for Science and Technology, P.O. Box 6086, Riyadh 11442, Saudi Arabia
1 shared publication - Maha Abdallah Alnuwaiser
Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Corrosion Behavior of Aluminium-Coated Cans
Hundreds of billions of aluminium-based cans are manufactured and used every year worldwide including those containing soft drinks. This study investigates and evaluates the performance and quality of two well-known energy and soft drinks brands, Green Cola and Red Bull. Recent health hazards and concerns have been associated with aluminium leakage and bisphenol A (BPA) dissociation from the can’s internal protective coating. The cans were examined under four conditions, including coated and uncoated samples, the soft drink’s main solution, and 0.1 M acetic acid solution. Electrochemical measurements such as potentiodynamic polarization and impedance spectroscopy (EIS), element analyses using inductively coupled plasma optical emission spectrometry (ICP-OES), and energy dispersive X-ray spectroscopy (EDS) were performed. In addition, sample characterization by scanning electron microscopy (SEM) and X-ray diffraction spectroscopy (XRD) were employed to comprehensively study and analyze the effect of corrosion on the samples. Even though the internal coating provided superior corrosion protection concerning main or acetic acid solutions, it failed to prevent aluminium from dissolving in the electrolyte. Green Cola’s primary solution appears to be extremely corrosive, as the corrosion rate increased by approximately 333% relative to the acetic acid solution. Uncoated samples resulted in increases in the percentage of oxygen, the appearance of more corrosion spots, and decreases in crystallinity. The ICP-OES test detected dangerous levels of aluminium in the Green Cola solution, which increased significantly after increasing the conductivity of the solution.
Open AccessCorrosion Behavior of Aluminium-Coated Cans
Hundreds of billions of aluminium-based cans are manufactured and used every year worldwide including those containing soft drinks. This study investigates and evaluates the performance and quality of two well-known energy and soft drinks brands, Green Cola and Red Bull. Recent health hazards and concerns have been associated with aluminium leakage and bisphenol A (BPA) dissociation from the can’s internal protective coating. The cans were examined under four conditions, including coated and uncoated samples, the soft drink’s main solution, and 0.1 M acetic acid solution. Electrochemical measurements such as potentiodynamic polarization and impedance spectroscopy (EIS), element analyses using inductively coupled plasma optical emission spectrometry (ICP-OES), and energy dispersive X-ray spectroscopy (EDS) were performed. In addition, sample characterization by scanning electron microscopy (SEM) and X-ray diffraction spectroscopy (XRD) were employed to comprehensively study and analyze the effect of corrosion on the samples. Even though the internal coating provided superior corrosion protection concerning main or acetic acid solutions, it failed to prevent aluminium from dissolving in the electrolyte. Green Cola’s primary solution appears to be extremely corrosive, as the corrosion rate increased by approximately 333% relative to the acetic acid solution. Uncoated samples resulted in increases in the percentage of oxygen, the appearance of more corrosion spots, and decreases in crystallinity. The ICP-OES test detected dangerous levels of aluminium in the Green Cola solution, which increased significantly after increasing the conductivity of the solution.
- Open Access
Electrochemical Behavior of SiC-Coated AA2014 Alloy through Plasma Electrolytic Oxidation
In this study, the corrosion performance of AA2014 aluminum alloy was enhanced by coating the alloy with a layer containing silica (SiC) that was formed by the plasma electrolytic oxidation (PEO) process. The PEO process was performed with different electrical parameters (frequency, current mode, and duty ratio) and both with and without SiC to investigate the microstructural and electrochemical differences in the coated samples produced from the process. The microstructure and composition of the PEO coatings were studied using X-ray diffraction (XRD) and scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS). A potentiodynamic polarization test and electrochemical impedance spectroscopy (EIS) were used to investigate the electrochemical behavior of the AA2014-PEO-coated samples. The potentiodynamic polarization showed that the SiC-PEO-coated samples had a significantly decreased corrosion rate (99.8%) compared with the uncoated AA2014 Al alloy. Our results showed that the coats containing SiC possessed a much higher corrosion resistance than both the uncoated AA2014 Al alloy (8,344,673%) and the SiC-free coatings, which possess low corrosion resistance, because of their higher chemical stability and more compact microstructure.
Open AccessElectrochemical Behavior of SiC-Coated AA2014 Alloy through Plasma Electrolytic Oxidation
In this study, the corrosion performance of AA2014 aluminum alloy was enhanced by coating the alloy with a layer containing silica (SiC) that was formed by the plasma electrolytic oxidation (PEO) process. The PEO process was performed with different electrical parameters (frequency, current mode, and duty ratio) and both with and without SiC to investigate the microstructural and electrochemical differences in the coated samples produced from the process. The microstructure and composition of the PEO coatings were studied using X-ray diffraction (XRD) and scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS). A potentiodynamic polarization test and electrochemical impedance spectroscopy (EIS) were used to investigate the electrochemical behavior of the AA2014-PEO-coated samples. The potentiodynamic polarization showed that the SiC-PEO-coated samples had a significantly decreased corrosion rate (99.8%) compared with the uncoated AA2014 Al alloy. Our results showed that the coats containing SiC possessed a much higher corrosion resistance than both the uncoated AA2014 Al alloy (8,344,673%) and the SiC-free coatings, which possess low corrosion resistance, because of their higher chemical stability and more compact microstructure.