Stephen Kee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stephen Kee has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Adam N. Plotnik
Division of Interventional Radiology, Department of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, USA
2 shared publications - Zachary Haber
Division of Interventional Radiology, Department of Radiology, David Geffen School of Medicine at UCLA, Los Angeles, USA
2 shared publications - Clare Bent
Department of Interventional Radiology, University Hospitals Dorset, Bournemouth, UK
1 shared publication - Edward Wolfgang Lee
Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA; Division of Liver and Pancreas Transplant Surgery, Department of Surgery, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA
1 shared publication - Fady M. Kaldas
Department of Surgery, University of California Los Angeles, Los Angeles, California, USA
1 shared publication Gerry O’sullivan
Department of Radiology, Galway University Hospital, Galway, Ireland
1 shared publication
Latest Publications
- 14 November 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (12) , 1595-1604
Early Thrombus Removal for Acute Lower Extremity Deep Vein Thrombosis: Update on Inclusion, Technical Aspects, and Postprocedural Management
Acute lower extremity deep vein thrombosis (DVT) is a common disorder with significant associated morbidity, including pain and swelling, as well as the risk of pulmonary embolism (PE), recurrent venous thromboembolism (VTE) and chronic debilitating post-thrombotic syndrome (PTS). Anticoagulation is standard of care for DVT treatment. It assists in reducing thrombus progression and the occurrence of PE, but incomplete DVT resolution increases the risk of recurrent VTE, valvular insufficiency, and PTS. Endovascular DVT interventions, such as catheter-directed thrombolysis, pharmacomechanical thrombectomy, and large-bore mechanical thrombectomy offer an alternative therapeutic strategy for DVT management. This paper will discuss technical factors and current issues when performing lower extremity DVT interventions including patient selection, anticoagulation, choice of device for endovascular thrombus removal, adjunctive techniques, and venous stent management. Level of Evidence: No level of evidence for: review articles, basic science, laboratory investigations, and experimental study articles.
- 14 November 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (12) , 1595-1604
Early Thrombus Removal for Acute Lower Extremity Deep Vein Thrombosis: Update on Inclusion, Technical Aspects, and Postprocedural Management
Acute lower extremity deep vein thrombosis (DVT) is a common disorder with significant associated morbidity, including pain and swelling, as well as the risk of pulmonary embolism (PE), recurrent venous thromboembolism (VTE) and chronic debilitating post-thrombotic syndrome (PTS). Anticoagulation is standard of care for DVT treatment. It assists in reducing thrombus progression and the occurrence of PE, but incomplete DVT resolution increases the risk of recurrent VTE, valvular insufficiency, and PTS. Endovascular DVT interventions, such as catheter-directed thrombolysis, pharmacomechanical thrombectomy, and large-bore mechanical thrombectomy offer an alternative therapeutic strategy for DVT management. This paper will discuss technical factors and current issues when performing lower extremity DVT interventions including patient selection, anticoagulation, choice of device for endovascular thrombus removal, adjunctive techniques, and venous stent management. Level of Evidence: No level of evidence for: review articles, basic science, laboratory investigations, and experimental study articles.
- 24 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (12) , 1571-1579
Current Evidence for Endovascular Therapies in the Management of Acute Deep Vein Thrombosis
Acute lower extremity deep vein thrombosis (DVT), specifically proximal iliofemoral DVT, is a relatively common disorder that can result in a chronic debilitating post-thrombotic syndrome (PTS), with a significant effect on a patient’s quality of life. Anticoagulation is first-line therapy; however, percutaneous interventions have emerged as treatment options for patients where there is concern that anticoagulation alone will not resolve the DVT as well as prevent PTS. This paper will discuss the existing data on these interventions and review current endovascular techniques, including catheter-directed thrombolysis, pharmacomechanical thrombectomy, and large-bore mechanical thrombectomy in the management of DVT.
- 24 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (12) , 1571-1579
Current Evidence for Endovascular Therapies in the Management of Acute Deep Vein Thrombosis
Acute lower extremity deep vein thrombosis (DVT), specifically proximal iliofemoral DVT, is a relatively common disorder that can result in a chronic debilitating post-thrombotic syndrome (PTS), with a significant effect on a patient’s quality of life. Anticoagulation is first-line therapy; however, percutaneous interventions have emerged as treatment options for patients where there is concern that anticoagulation alone will not resolve the DVT as well as prevent PTS. This paper will discuss the existing data on these interventions and review current endovascular techniques, including catheter-directed thrombolysis, pharmacomechanical thrombectomy, and large-bore mechanical thrombectomy in the management of DVT.
- 21 March 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (4) , 503-507
Performance Evaluation of a Miniature and Disposable Endovascular Robotic Device
Purpose The LIBERTY® Robotic System is a miniature, single-use device designed to facilitate remote-controlled navigation to intravascular targets. We aim to evaluate the robot’s performance to manipulate a range of microguidewires and microcatheters during percutaneous endovascular procedures. Materials and Methods Six interventional radiologists performed selective robotic-assisted catheterization of eight pre-determined vascular targets in a pig model. The navigation time from the guiding catheter tip to the target vessel was recorded. Each physician with a clinical experience of 20 years completed a questionnaire to evaluate the ease of use, accuracy, and safety of the robotic operation. Results Most of the physicians reached the vascular targets in less than one minute. There was no angiographic evidence of vascular injury such as artery laceration or contusion. All physicians reported consensus about the high performance of the robot. Conclusion The miniature disposable robot is effective at reaching a range of vessels in a porcine model. Physicians found the device intuitive and easy to operate remotely. Graphical Abstract
- 21 March 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (4) , 503-507
Performance Evaluation of a Miniature and Disposable Endovascular Robotic Device
Purpose The LIBERTY® Robotic System is a miniature, single-use device designed to facilitate remote-controlled navigation to intravascular targets. We aim to evaluate the robot’s performance to manipulate a range of microguidewires and microcatheters during percutaneous endovascular procedures. Materials and Methods Six interventional radiologists performed selective robotic-assisted catheterization of eight pre-determined vascular targets in a pig model. The navigation time from the guiding catheter tip to the target vessel was recorded. Each physician with a clinical experience of 20 years completed a questionnaire to evaluate the ease of use, accuracy, and safety of the robotic operation. Results Most of the physicians reached the vascular targets in less than one minute. There was no angiographic evidence of vascular injury such as artery laceration or contusion. All physicians reported consensus about the high performance of the robot. Conclusion The miniature disposable robot is effective at reaching a range of vessels in a porcine model. Physicians found the device intuitive and easy to operate remotely. Graphical Abstract
- Open Access
- 23 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5267
Single Puncture TIPS—A 3D Fusion Image-Guided Transjugular Intrahepatic Portosystemic Shunt (TIPS): An Experimental Study
Background: The use of a transjugular intrahepatic portosystemic shunt (TIPS) has been established as an effective treatment for portal hypertension. Despite the rapid development of this use, serious peri-procedural complications have been reported in over 10% of cases. This has largely been attributed to the access to the portal vein, also referred to as a “blind puncture”, which often requires multiple attempts. The aim of this study was to demonstrate the safety, reproducibility and accuracy of the use of real-time 3D fusion image-guided (3DFIG) single puncture TIPS to minimize the complications that are related to the “blind puncture” of TIPS procedures. Methods: A 3DFIG TIPS approach was utilized on 22 pigs by combining pre-procedural cross-sectional imaging (CT, MR or CBCT) with intra-procedural cone beam CT or angiogram imaging, which allowed for the improved 3D visual spatial orientation of the portal vein and real-time tracking of the needle in 3D. Results: Thirty-five portosystemic shunts were successfully deployed in all 22 subjects without any peri-procedural complications. Overall, 91% (32/35) of the procedures were carried out using a single puncture. In addition, the mean fluoroscopy time in our study was more than 12 times lower than the proposed reference level that has previously been proposed for TIPS procedures. Conclusion: Multi-modality real-time 3DFIG TIPS can be performed safely using a single puncture, without complications, and can potentially be used in both emergency and non-emergency clinical situations.
- 23 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5267
Open AccessSingle Puncture TIPS—A 3D Fusion Image-Guided Transjugular Intrahepatic Portosystemic Shunt (TIPS): An Experimental Study
Background: The use of a transjugular intrahepatic portosystemic shunt (TIPS) has been established as an effective treatment for portal hypertension. Despite the rapid development of this use, serious peri-procedural complications have been reported in over 10% of cases. This has largely been attributed to the access to the portal vein, also referred to as a “blind puncture”, which often requires multiple attempts. The aim of this study was to demonstrate the safety, reproducibility and accuracy of the use of real-time 3D fusion image-guided (3DFIG) single puncture TIPS to minimize the complications that are related to the “blind puncture” of TIPS procedures. Methods: A 3DFIG TIPS approach was utilized on 22 pigs by combining pre-procedural cross-sectional imaging (CT, MR or CBCT) with intra-procedural cone beam CT or angiogram imaging, which allowed for the improved 3D visual spatial orientation of the portal vein and real-time tracking of the needle in 3D. Results: Thirty-five portosystemic shunts were successfully deployed in all 22 subjects without any peri-procedural complications. Overall, 91% (32/35) of the procedures were carried out using a single puncture. In addition, the mean fluoroscopy time in our study was more than 12 times lower than the proposed reference level that has previously been proposed for TIPS procedures. Conclusion: Multi-modality real-time 3DFIG TIPS can be performed safely using a single puncture, without complications, and can potentially be used in both emergency and non-emergency clinical situations.