Mrunalini Harish Kulkarni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mrunalini Harish Kulkarni has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Aditi Sharma
Department of Computer Science Engineering & Information Technology, Institute of Engineering & Technology (An Autonomous Constituent Institute of Dr. A.P.J. Abdul Kalam Technical University), UP, Lucknow, India
1 shared publication - Akhilesh Kumar
Department of Information Technology, Gaya College, Gaya, India
1 shared publication - Ali Alferaidi
College of Computer Science & Engineering, University of Ha’il, Ha’il, Saudi Arabia
1 shared publication - Aman Kushwaha
Department of Pharmaceutical Chemistry, R.K. College of Pharmacy, Mavaiya, Naini, Prayagraj, Uttar Pradesh, India
1 shared publication - Chaitanya Shrikant Kulkarni
Shri JJT University Vidyanagari Rajasthan India
1 shared publication - D. Dinesh Kumar
Department of Electronics and Instrumentation Engineering, St. Joseph’s College of Engineering, Chennai – 600119, Tamil Nadu
1 shared publication
Latest Publications
- Open Access
- 30 October 2026
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 5 (42) , 1988
Synthesis and Evaluation of 1,3,4-Oxadiazole Derivatives as Multi-Target Neuroprotective Agents Against Alzheimer’s Disease
Alzheimer's disease (AD) represents a progressive multifactorial neurodegenerative condition marked by deterioration of cognitive function, accumulation of amyloid-β (Aβ) plaques, formation of neurofibrillary tangles, and increased oxidative stress. Existing therapeutic approaches provide only symptomatic management, underscoring the critical demand for multi-target-directed ligands (MTDLs) capable of concurrently addressing multiple pathological mechanisms. This investigation synthesized a collection of 1,3,4-oxadiazole compounds, encompassing quinoline-1,3,4-oxadiazole conjugates, coumarin-linked compounds (PP-384–PP-390), and 5-substituted-2-anilino-1,3,4-oxadiazole analogs (4a-g, 5a-g, 9a-g, and 13a-g), which were subsequently assessed for their potential as multi-target protective agents in AD. Structural characterization was accomplished through ¹H-NMR, ¹³C-NMR, IR spectroscopy, and mass spectrometry. In vitro enzymatic inhibition assays employing Ellman's spectrophotometric technique demonstrated that compound 5a from the 5-substituted-2-anilino series manifested remarkable inhibitory strength, displaying IC₅₀ concentrations of 46.9 nM for acetylcholinesterase (AChE) and 3.5 nM for butyrylcholinesterase (BuChE), representing substantially superior efficacy compared to the reference dual inhibitor Rivastigmine. The quinoline-1,3,4-oxadiazole conjugates similarly demonstrated considerable AChE suppression, with compound 5a attaining an IC₅₀ of 0.033 μM. In vivo investigations indicated that compound 5a effectively suppressed Aβ self-aggregation, diminished malondialdehyde (MDA) concentrations, and augmented glutathione (GSH) levels in cerebral tissue extracts, thereby mitigating oxidative stress. Histological analysis documented diminished neuronal deterioration alongside reduced caspase-3 and VEGF levels. Computational docking and molecular dynamics assessments validated robust binding affinities with targeted enzymes. All synthesized compounds exhibited satisfactory ADMET characteristics and compliance with Lipinski's rule of five. These observations indicate that 1,3,4-oxadiazole derivatives, notably compound 5a, represent encouraging multi-target protective candidates for AD management.
- 30 October 2026
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 5 (42) , 1988
Open AccessSynthesis and Evaluation of 1,3,4-Oxadiazole Derivatives as Multi-Target Neuroprotective Agents Against Alzheimer’s Disease
Alzheimer's disease (AD) represents a progressive multifactorial neurodegenerative condition marked by deterioration of cognitive function, accumulation of amyloid-β (Aβ) plaques, formation of neurofibrillary tangles, and increased oxidative stress. Existing therapeutic approaches provide only symptomatic management, underscoring the critical demand for multi-target-directed ligands (MTDLs) capable of concurrently addressing multiple pathological mechanisms. This investigation synthesized a collection of 1,3,4-oxadiazole compounds, encompassing quinoline-1,3,4-oxadiazole conjugates, coumarin-linked compounds (PP-384–PP-390), and 5-substituted-2-anilino-1,3,4-oxadiazole analogs (4a-g, 5a-g, 9a-g, and 13a-g), which were subsequently assessed for their potential as multi-target protective agents in AD. Structural characterization was accomplished through ¹H-NMR, ¹³C-NMR, IR spectroscopy, and mass spectrometry. In vitro enzymatic inhibition assays employing Ellman's spectrophotometric technique demonstrated that compound 5a from the 5-substituted-2-anilino series manifested remarkable inhibitory strength, displaying IC₅₀ concentrations of 46.9 nM for acetylcholinesterase (AChE) and 3.5 nM for butyrylcholinesterase (BuChE), representing substantially superior efficacy compared to the reference dual inhibitor Rivastigmine. The quinoline-1,3,4-oxadiazole conjugates similarly demonstrated considerable AChE suppression, with compound 5a attaining an IC₅₀ of 0.033 μM. In vivo investigations indicated that compound 5a effectively suppressed Aβ self-aggregation, diminished malondialdehyde (MDA) concentrations, and augmented glutathione (GSH) levels in cerebral tissue extracts, thereby mitigating oxidative stress. Histological analysis documented diminished neuronal deterioration alongside reduced caspase-3 and VEGF levels. Computational docking and molecular dynamics assessments validated robust binding affinities with targeted enzymes. All synthesized compounds exhibited satisfactory ADMET characteristics and compliance with Lipinski's rule of five. These observations indicate that 1,3,4-oxadiazole derivatives, notably compound 5a, represent encouraging multi-target protective candidates for AD management.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems, Man, and Cybernetics Magazine
- Vol. 10 (4) , 32-39
Location Word Embedding: An Approach for Rumor Detection Over Social Internet of Things
With the emergence of online social networks, the dissemination and acquisition of information have experienced dramatic transformations. While social media makes peoples’ lives easier, it also speeds up the creation and spread of rumors. Therefore, solving the problem of reliably and effectively recognizing words has become a critical need. The global–local attention network (GLAN)-based rumor detection model has been improved to improve its accuracy. Considering the impact of the positioning relationship among words in text on rumor identification, a new relative positional encoding method is utilized to enhance the original model’s local feature extraction module. This method can more precisely extract the semantic and location information of the text in a rumor and aggregate it to provide a better text feature that differentiates rumors from nonrumors. This characteristic is combined with the global element specifying forwarding behavior to increase the effectiveness of word detection. Experimental findings demonstrate that the F 1 value of the suggested method on the Weibo dataset may reach 95%, with a unique detection effect compared to other mainstream detection methods.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems, Man, and Cybernetics Magazine
- Vol. 10 (4) , 32-39
Location Word Embedding: An Approach for Rumor Detection Over Social Internet of Things
With the emergence of online social networks, the dissemination and acquisition of information have experienced dramatic transformations. While social media makes peoples’ lives easier, it also speeds up the creation and spread of rumors. Therefore, solving the problem of reliably and effectively recognizing words has become a critical need. The global–local attention network (GLAN)-based rumor detection model has been improved to improve its accuracy. Considering the impact of the positioning relationship among words in text on rumor identification, a new relative positional encoding method is utilized to enhance the original model’s local feature extraction module. This method can more precisely extract the semantic and location information of the text in a rumor and aggregate it to provide a better text feature that differentiates rumors from nonrumors. This characteristic is combined with the global element specifying forwarding behavior to increase the effectiveness of word detection. Experimental findings demonstrate that the F 1 value of the suggested method on the Weibo dataset may reach 95%, with a unique detection effect compared to other mainstream detection methods.
- Open Access
- 29 August 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-11
Breast Cancer Pathological Image Classification Based on the Multiscale CNN Squeeze Model
The use of an automatic histopathological image identification system is essential for expediting diagnoses and lowering mistake rates. Although it is of enormous clinical importance, computerized breast cancer multiclassification using histological pictures has rarely been investigated. A deep learning-based classification strategy is suggested to solve the challenge of automated categorization of breast cancer pathology pictures. The attention model that acts on the feature channel is the channel refinement model. The learned channel weight may be used to reduce superfluous features when implementing the feature channel. To increase classification accuracy, calibration is necessary. To increase the accuracy of channel recalibration findings, a multiscale channel recalibration model is provided, and the msSE-ResNet convolutional neural network is built. The multiscale properties flow through the network’s highest pooling layer. The channel weights obtained at different scales are delivered into line fusion and used as input to the next channel recalibration model, which may improve the results of channel recalibration. The experimental findings reveal that the spatial recalibration model fares poorly on the job of classifying breast cancer pathology pictures when applied to the semantic segmentation of brain MRI images. The public BreakHis dataset is used to conduct the experiment. The network performs benign/malignant breast pathology picture classification collected at various magnifications with a classification accuracy of 88.87 percent, according to experimental data. The diseased images are also more resilient. Experiments on pathological pictures at various magnifications show that msSE-ResNet34 is capable of performing well when used to classify pathological images at various magnifications.
- 29 August 2022
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2022, 1-11
Open AccessBreast Cancer Pathological Image Classification Based on the Multiscale CNN Squeeze Model
The use of an automatic histopathological image identification system is essential for expediting diagnoses and lowering mistake rates. Although it is of enormous clinical importance, computerized breast cancer multiclassification using histological pictures has rarely been investigated. A deep learning-based classification strategy is suggested to solve the challenge of automated categorization of breast cancer pathology pictures. The attention model that acts on the feature channel is the channel refinement model. The learned channel weight may be used to reduce superfluous features when implementing the feature channel. To increase classification accuracy, calibration is necessary. To increase the accuracy of channel recalibration findings, a multiscale channel recalibration model is provided, and the msSE-ResNet convolutional neural network is built. The multiscale properties flow through the network’s highest pooling layer. The channel weights obtained at different scales are delivered into line fusion and used as input to the next channel recalibration model, which may improve the results of channel recalibration. The experimental findings reveal that the spatial recalibration model fares poorly on the job of classifying breast cancer pathology pictures when applied to the semantic segmentation of brain MRI images. The public BreakHis dataset is used to conduct the experiment. The network performs benign/malignant breast pathology picture classification collected at various magnifications with a classification accuracy of 88.87 percent, according to experimental data. The diseased images are also more resilient. Experiments on pathological pictures at various magnifications show that msSE-ResNet34 is capable of performing well when used to classify pathological images at various magnifications.
- Open Access
- 23 May 2022
- Published by Hindawi Limited in Scientific Programming
- Vol. 2022, 1-10
Data Fusion Approach for Managing Clinical Data in an Industrial Environment using IoT
As health issues continue to become more prevalent as the population grows, building a public health network is critical for enhancing the overall health quality of the community. This study offers an Internet of Things (IoT) based health care system that can be employed in the context of community medical care industrial areas. The main focus of this research is to develop a disease prediction strategy that could be applied to community health services using theoretical modelling. Using principal component analysis (PCA) and cluster analysis, an artificial bee colony (ABC) creates a nonlinear support vector machine (SVM) classifier pair. Feature-level fusion analysis was performed to detect probable abnormalities. The results of the experiments reveal that the SVM model offers significant benefits in disease prediction. In the SVM illness prediction model, the ABC algorithm has the best parameter optimization effect in terms of accuracy, time, and other factors. The suggested method outperformed the traditional SVM and BP neural network methods by 17.24 percent and 72.41 percent, respectively. It can lower the RMSE and improve assessment indicators like the precision recall rate and the F-measure, demonstrating the method’s validity and accuracy. As a result, it is frequently used in community health management, geriatric community monitoring, and clinical medical therapy in an industrial environment.
- 23 May 2022
- Published by Hindawi Limited in Scientific Programming
- Vol. 2022, 1-10
Open AccessData Fusion Approach for Managing Clinical Data in an Industrial Environment using IoT
As health issues continue to become more prevalent as the population grows, building a public health network is critical for enhancing the overall health quality of the community. This study offers an Internet of Things (IoT) based health care system that can be employed in the context of community medical care industrial areas. The main focus of this research is to develop a disease prediction strategy that could be applied to community health services using theoretical modelling. Using principal component analysis (PCA) and cluster analysis, an artificial bee colony (ABC) creates a nonlinear support vector machine (SVM) classifier pair. Feature-level fusion analysis was performed to detect probable abnormalities. The results of the experiments reveal that the SVM model offers significant benefits in disease prediction. In the SVM illness prediction model, the ABC algorithm has the best parameter optimization effect in terms of accuracy, time, and other factors. The suggested method outperformed the traditional SVM and BP neural network methods by 17.24 percent and 72.41 percent, respectively. It can lower the RMSE and improve assessment indicators like the precision recall rate and the F-measure, demonstrating the method’s validity and accuracy. As a result, it is frequently used in community health management, geriatric community monitoring, and clinical medical therapy in an industrial environment.