Chris Duszynski
Research Subjects
Research Interests
Chris Duszynski has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alireza Sojoudi
Circle Neurovascular Imaging Inc., Calgary, Canada
1 shared publication - Benjamin Beland
Department of Clinical Neurosciences, Cumming School of Medicine University of Calgary Calgary Alberta Canada
1 shared publication - Bijoy K. Menon
Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada
1 shared publication - Fouzi Bala
University of Calgary
1 shared publication - Houssam El-Hariri
Circle Neurovascular Imaging Inc., Calgary, Canada
1 shared publication Ibukun Elebute
Circle Neurovascular Imaging Inc., Calgary, Canada
1 shared publication
Latest Publications
- 24 May 2022
- Published by Springer Nature in Neuroradiology
- Vol. 64 (12) , 2245-2255
Validation of a machine learning software tool for automated large vessel occlusion detection in patients with suspected acute stroke
Purpose CT angiography (CTA) is the imaging standard for large vessel occlusion (LVO) detection in patients with acute ischemic stroke. StrokeSENS LVO is an automated tool that utilizes a machine learning algorithm to identify anterior large vessel occlusions (LVO) on CTA. The aim of this study was to test the algorithm’s performance in LVO detection in an independent dataset. Methods A total of 400 studies (217 LVO, 183 other/no occlusion) read by expert consensus were used for retrospective analysis. The LVO was defined as intracranial internal carotid artery (ICA) occlusion and M1 middle cerebral artery (MCA) occlusion. Software performance in detecting anterior LVO was evaluated using receiver operator characteristics (ROC) analysis, reporting area under the curve (AUC), sensitivity, and specificity. Subgroup analyses were performed to evaluate if performance in detecting LVO differed by subgroups, namely M1 MCA and ICA occlusion sites, and in data stratified by patient age, sex, and CTA acquisition characteristics (slice thickness, kilovoltage tube peak, and scanner manufacturer). Results AUC, sensitivity, and specificity overall were as follows: 0.939, 0.894, and 0.874, respectively, in the full cohort; 0.927, 0.857, and 0.874, respectively, in the ICA occlusion cohort; 0.945, 0.914, and 0.874, respectively, in the M1 MCA occlusion cohort. Performance did not differ significantly by patient age, sex, or CTA acquisition characteristics. Conclusion The StrokeSENS LVO machine learning algorithm detects anterior LVO with high accuracy from a range of scans in a large dataset.
- 24 May 2022
- Published by Springer Nature in Neuroradiology
- Vol. 64 (12) , 2245-2255
Validation of a machine learning software tool for automated large vessel occlusion detection in patients with suspected acute stroke
Purpose CT angiography (CTA) is the imaging standard for large vessel occlusion (LVO) detection in patients with acute ischemic stroke. StrokeSENS LVO is an automated tool that utilizes a machine learning algorithm to identify anterior large vessel occlusions (LVO) on CTA. The aim of this study was to test the algorithm’s performance in LVO detection in an independent dataset. Methods A total of 400 studies (217 LVO, 183 other/no occlusion) read by expert consensus were used for retrospective analysis. The LVO was defined as intracranial internal carotid artery (ICA) occlusion and M1 middle cerebral artery (MCA) occlusion. Software performance in detecting anterior LVO was evaluated using receiver operator characteristics (ROC) analysis, reporting area under the curve (AUC), sensitivity, and specificity. Subgroup analyses were performed to evaluate if performance in detecting LVO differed by subgroups, namely M1 MCA and ICA occlusion sites, and in data stratified by patient age, sex, and CTA acquisition characteristics (slice thickness, kilovoltage tube peak, and scanner manufacturer). Results AUC, sensitivity, and specificity overall were as follows: 0.939, 0.894, and 0.874, respectively, in the full cohort; 0.927, 0.857, and 0.874, respectively, in the ICA occlusion cohort; 0.945, 0.914, and 0.874, respectively, in the M1 MCA occlusion cohort. Performance did not differ significantly by patient age, sex, or CTA acquisition characteristics. Conclusion The StrokeSENS LVO machine learning algorithm detects anterior LVO with high accuracy from a range of scans in a large dataset.