Minjie Zhuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minjie Zhuang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Yiqun Wu
Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China
2 shared publications - Baoxin Tao
Department of Second Dental Center, Shanghai Ninth People's Hospital Shanghai Jiao Tong University School of Medicine Shanghai China
1 shared publication Feng Wang
Department of Second Dental Center Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine Shanghai China
1 shared publication- Feng Wang
Oral and Maxillofacial Surgery, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
1 shared publication - Feng Wang
Department of Thoracic Oncology Surgery, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, China
1 shared publication - Jian Sun
Department of Cardiology, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication
Latest Publications
- 15 October 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Exploring the Learning Curve of Dental Implant Placement Using a Task‐Autonomous Robotic System Among Young Dentists From Different Specialties—A Pilot Module Study
Background: The learning curve effect of dynamic computer‐assisted implant surgery (D‐CAIS) was observed among inexperienced novice surgeons. The learning curves can provide valuable information for novice surgeons and valid comparisons between new and conventional techniques. Recently, robotic computer‐assisted implant surgery (R‐CAIS) has shown promise as a novel dental implant surgical technique for both partially and edentulous patients. However, its learning curve remains unknown.Purpose: The aim of this study was to explore the learning curve of dental implant placement surgery with a task‐autonomous robotic system among young dentists with different specialties.Methods and Materials: Four young dentists (mean age: 25.3 ± 1.5 years at the beginning of their first attempt) with equal representation of males and females and with different specialties participated in this study. None of the participants had prior experience in R‐CAIS. Each operator placed eight implants over eight attempts using a semi‐active task‐autonomous robotic system. Among the eight implants, four were straight lateral incisor implants, and four were 30°‐tilted premolar implants. The implants were placed in each dental quadrant of the maxillary and mandibular jaw modules. The operation time was recorded. Coronal, apical, and angular deviations between the planned and actual sites of implant placement were measured by merging preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The data were analyzed with repeated‐measures ANOVA (α = 0.05).Results: The mean time for implant placement was associated with the number of attempts (p < 0.01). The time taken for the second attempt was significantly shorter than that of the first attempt (33.26 vs. 30.47 min; p < 0.001) then it plateaued. Three‐dimensional (3D) angular (p = 0.31), coronal deviation (p = 0.26), and apical deviation (p = 0.06) did not differ significantly among attempts. The mean values and standard deviations of 3D coronal deviation, 3D apical deviation, and 3D angular deviation were 0.71 ± 0.31 mm, 0.72 ± 0.30 mm, and 0.94 ± 0.58°, respectively. Neither the position of the jaw (p > 0.59) nor the tilt angle of the implant (straight or 30°‐tilted, p > 0.85) was related to implant placement accuracy.Conclusions: Dentists quickly learned the basic workflow of R‐CAIS and thus facilitated the clinicians in the mastery of implant placement on edentulous jaw modules, leading to a comparable operating speed and high precision. Moreover, the accuracy of placement of straight and tilted implants in both the maxilla and mandible with R‐CAIS was satisfactory.
- 15 October 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Exploring the Learning Curve of Dental Implant Placement Using a Task‐Autonomous Robotic System Among Young Dentists From Different Specialties—A Pilot Module Study
Background: The learning curve effect of dynamic computer‐assisted implant surgery (D‐CAIS) was observed among inexperienced novice surgeons. The learning curves can provide valuable information for novice surgeons and valid comparisons between new and conventional techniques. Recently, robotic computer‐assisted implant surgery (R‐CAIS) has shown promise as a novel dental implant surgical technique for both partially and edentulous patients. However, its learning curve remains unknown.Purpose: The aim of this study was to explore the learning curve of dental implant placement surgery with a task‐autonomous robotic system among young dentists with different specialties.Methods and Materials: Four young dentists (mean age: 25.3 ± 1.5 years at the beginning of their first attempt) with equal representation of males and females and with different specialties participated in this study. None of the participants had prior experience in R‐CAIS. Each operator placed eight implants over eight attempts using a semi‐active task‐autonomous robotic system. Among the eight implants, four were straight lateral incisor implants, and four were 30°‐tilted premolar implants. The implants were placed in each dental quadrant of the maxillary and mandibular jaw modules. The operation time was recorded. Coronal, apical, and angular deviations between the planned and actual sites of implant placement were measured by merging preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The data were analyzed with repeated‐measures ANOVA (α = 0.05).Results: The mean time for implant placement was associated with the number of attempts (p < 0.01). The time taken for the second attempt was significantly shorter than that of the first attempt (33.26 vs. 30.47 min; p < 0.001) then it plateaued. Three‐dimensional (3D) angular (p = 0.31), coronal deviation (p = 0.26), and apical deviation (p = 0.06) did not differ significantly among attempts. The mean values and standard deviations of 3D coronal deviation, 3D apical deviation, and 3D angular deviation were 0.71 ± 0.31 mm, 0.72 ± 0.30 mm, and 0.94 ± 0.58°, respectively. Neither the position of the jaw (p > 0.59) nor the tilt angle of the implant (straight or 30°‐tilted, p > 0.85) was related to implant placement accuracy.Conclusions: Dentists quickly learned the basic workflow of R‐CAIS and thus facilitated the clinicians in the mastery of implant placement on edentulous jaw modules, leading to a comparable operating speed and high precision. Moreover, the accuracy of placement of straight and tilted implants in both the maxilla and mandible with R‐CAIS was satisfactory.
- 25 May 2022
- Published by Wiley in European Journal of Dental Education
- Vol. 27 (3) , 438-448
Exploring training dental implant placement using static or dynamic devices among dental students
Background: Static computer‐assisted surgery (s‐CAIS) and dynamic computer‐assisted implant surgery (d‐CAIS) are the main digital approaches in guiding dental implant placement.Purpose: The aim of this study was to explore and compare the learning curves for s‐CAIS and d‐CAIS by beginners.Materials and Methods: Three dental students used each dental model for drilling five positions with missing teeth. Operators performed the drilling test for five sets of dental models with an interval of 7 ± 1 days assisted by the d‐CAIS system. After a six‐month break, the same students performed the drilling test again in the same way but with the s‐CAIS system. A total of thirty models were used, and 150 implants were inserted. The operation time and relative deviations were recorded and calculated. Correlations between various deviation parameters and attempts were tested with independent‐samples Kruskal–Wallis tests.Results: A significant difference between the two groups was found in the operation time (p < .001). For accuracy, the difference was found in the first attempt of coronal and apical deviations but disappeared as the training went on. As the practice progressed, improvement was evident in the d‐CAIS group but not in the s‐CAIS group. When reaching the plateau stage of the learning curve of the d‐CAIS group (after five attempts), the influence of different methods of guidance was limited between the two groups.Conclusions: A learning curve effect was found in d‐CAIS but not in s‐CAIS in vitro tests by beginners. The operating procedure of dynamic navigated and static template‐guided implant placement was easy to master.
- 25 May 2022
- Published by Wiley in European Journal of Dental Education
- Vol. 27 (3) , 438-448
Exploring training dental implant placement using static or dynamic devices among dental students
Background: Static computer‐assisted surgery (s‐CAIS) and dynamic computer‐assisted implant surgery (d‐CAIS) are the main digital approaches in guiding dental implant placement.Purpose: The aim of this study was to explore and compare the learning curves for s‐CAIS and d‐CAIS by beginners.Materials and Methods: Three dental students used each dental model for drilling five positions with missing teeth. Operators performed the drilling test for five sets of dental models with an interval of 7 ± 1 days assisted by the d‐CAIS system. After a six‐month break, the same students performed the drilling test again in the same way but with the s‐CAIS system. A total of thirty models were used, and 150 implants were inserted. The operation time and relative deviations were recorded and calculated. Correlations between various deviation parameters and attempts were tested with independent‐samples Kruskal–Wallis tests.Results: A significant difference between the two groups was found in the operation time (p < .001). For accuracy, the difference was found in the first attempt of coronal and apical deviations but disappeared as the training went on. As the practice progressed, improvement was evident in the d‐CAIS group but not in the s‐CAIS group. When reaching the plateau stage of the learning curve of the d‐CAIS group (after five attempts), the influence of different methods of guidance was limited between the two groups.Conclusions: A learning curve effect was found in d‐CAIS but not in s‐CAIS in vitro tests by beginners. The operating procedure of dynamic navigated and static template‐guided implant placement was easy to master.
- 11 February 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25 (9) , 5197-5204
The effect of anatomy on osteogenesis after maxillary sinus floor augmentation: a radiographic and histological analysis
Objectives To assess how anatomy and osteogenesis correlated with results of maxillary sinus floor augmentation (MSFA). Materials and methods Patients with partial edentulism and advanced atrophy of the posterior maxillae (≤ 4 mm residual bone height, RBH) underwent MSFA with sole deproteinized bovine bone matrix (DBBM) through a lateral approach. After a 6 to 9-month healing period, bone core biopsies were obtained from the sites of implant insertion for histological evaluation. The correlations between anatomical and histomorphometric variables were analyzed in a multiple regression model. Results Forty-nine patients were recruited. One biopsy per patient was obtained from the augmented sinus. Thirty-seven bone core biopsies were intact and met the requirement for histomorphometry analysis. The mean (± standard deviation) percentages of vital bone (VB), remaining DBBM, and non-mineralized tissue were 18.25 ± 4.76%, 27.74 ± 6.68%, and 54.08 ± 6.07%, respectively. No statistically significant correlations were found between RBH and VB% (p = 0.44) or between sinus contour and VB% (p = 0.33). However, there was an inverse correlation between the sinus width (SW) and VB % (SW1: R2 = 0.13, p = 0.03; SW2: R2 = 0.15, p = 0.02). Conclusions After a healing period of 6–9 months, wider sinuses augmented with DBBM alone tended to have a lower proportion of new bone formation, while RBH and sinus contour did not appear to affect osteogenesis after MSFA. Clinical relevance This study emphasized the effect of anatomy on osteogenesis after MSFA. The result of the study may have an indication to the clinician that SW is a consideration when selecting the bone grafting material and deciding the healing period of MSFA.
- 11 February 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 25 (9) , 5197-5204
The effect of anatomy on osteogenesis after maxillary sinus floor augmentation: a radiographic and histological analysis
Objectives To assess how anatomy and osteogenesis correlated with results of maxillary sinus floor augmentation (MSFA). Materials and methods Patients with partial edentulism and advanced atrophy of the posterior maxillae (≤ 4 mm residual bone height, RBH) underwent MSFA with sole deproteinized bovine bone matrix (DBBM) through a lateral approach. After a 6 to 9-month healing period, bone core biopsies were obtained from the sites of implant insertion for histological evaluation. The correlations between anatomical and histomorphometric variables were analyzed in a multiple regression model. Results Forty-nine patients were recruited. One biopsy per patient was obtained from the augmented sinus. Thirty-seven bone core biopsies were intact and met the requirement for histomorphometry analysis. The mean (± standard deviation) percentages of vital bone (VB), remaining DBBM, and non-mineralized tissue were 18.25 ± 4.76%, 27.74 ± 6.68%, and 54.08 ± 6.07%, respectively. No statistically significant correlations were found between RBH and VB% (p = 0.44) or between sinus contour and VB% (p = 0.33). However, there was an inverse correlation between the sinus width (SW) and VB % (SW1: R2 = 0.13, p = 0.03; SW2: R2 = 0.15, p = 0.02). Conclusions After a healing period of 6–9 months, wider sinuses augmented with DBBM alone tended to have a lower proportion of new bone formation, while RBH and sinus contour did not appear to affect osteogenesis after MSFA. Clinical relevance This study emphasized the effect of anatomy on osteogenesis after MSFA. The result of the study may have an indication to the clinician that SW is a consideration when selecting the bone grafting material and deciding the healing period of MSFA.