SWSenyao Wang

Senyao Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Senyao Wang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Bernhard Wolfrum

    Technical University of Munich

    3 shared publications
  • Hu Peng

    Neuroelectronics, Munich Institute of Biomedical Engineering Department of Electrical Engineering, TUM School of Computation, Information and Technology Technische Universität München Garching Deutschland

    3 shared publications
  • Ali Elmorsy

    Laboratory of Chemical Nanotechnology (CHEMINA) École Polytechnique Fédérale de Lausanne (EPFL) Genf Schweiz

    2 shared publications
  • Alonso Ingar Romero

    Neuroelectronics, Munich Institute of Biomedical Engineering Department of Electrical Engineering, TUM School of Computation, Information and Technology Technische Universität München Garching Deutschland

    2 shared publications
  • Berna Özkale

    Munich Institute of Biomedical Engineering Technical University of Munich Garching Germany

    2 shared publications
  • Chen Wang

    Microrobotic Bioengineering Lab Department of Electrical Engineering TUM School of Computation, Information and Technology Technische Universität München Garching Deutschland

    2 shared publications

Latest Publications

  • Open Access

    Interdigitale Aptamer‐Sensoren mit komplementären Messkanälen zur schnellen Detektion kleiner Moleküle in Biofluiden

    by Senyao Wang, Ali Elmorsy, Defne Tüzün, Lilly Schmidt, Sebastian Freko, Lukas Hiendlmeier, Chen Wang, Alonso Ingar Romero, George Al Boustani, Hu Peng, et al.

    KURZFASSUNG: Die schnelle und dezentrale Quantifizierung von niedermolekularen Biomarkern ist für die patientennahe Diagnostik (Point‐of‐Care, POC) unerlässlich, doch ihr zuverlässiger Nachweis in biologischen Flüssigkeiten bleibt eine Herausforderung. Um dieses Problem zu adressieren, stellen wir hier eine elektrochemische Aptamer‐Sensorplattform vor, welche eine komplementäre Signalumwandlungsstrategie an zwei Elektroden einsetzt. Durch die Integration zweier räumlich durch einen Spalt getrennten interdigitalen Arbeitselektroden mit selektiven selbstorganisierten Monoschichten (SAM) ermöglicht das System die zielgerichtete Freisetzung und Bindung von Methylenblau‐komplementären DNA‐Sonden (MB‐cDNA). Diese Konfiguration minimiert das Hintergrundrauschen und ermöglicht einen effizienten diffusiven Transport der Sonde zwischen den Elektroden, wodurch eine robuste komplementäre Signalwandlung erreicht wird. Die Plattform erlaubt einen schnellen (≤30 min.) Nachweis kleiner Moleküle (Dopamin und Cortisol) mit geringen Probenvolumina (30 µL) in unterschiedlichen biologischen Flüssigkeiten, einschließlich künstlicher Cerebrospinalflüssigkeit (aCSF), humanem Serum und Speichel. Der Signalumwandlungsmechanismus bleibt über verschiedene Zielmoleküle und Probentypen hinweg wirksam und erforderte lediglich eine Anpassung der DNA‐Sequenz. Insgesamt bietet der Ansatz eine vielseitige elektrochemische Sensorarchitektur mit breitem Potenzial für die schnelle, quantitative Analyse kleiner Moleküle in komplexen biologischen Medien.

  • Open Access

    Dual‐Channel Interdigitated Aptamer‐Based Sensors for Rapid Small‐Molecule Detection in Biofluids

    by Senyao Wang, Ali Elmorsy, Defne Tüzün, Lilly Schmidt, Sebastian Freko, Lukas Hiendlmeier, Chen Wang, Alonso Ingar Romero, George Al Boustani, Hu Peng, et al.

    Timely and decentralized quantification of small‐molecule biomarkers is essential for point‐of‐care (POC) diagnostics, but their reliable detection in biofluids remains challenging. Here, we introduce an engineered electrochemical aptamer sensing platform that employs a dual‐channel signal conversion strategy to overcome these limitations. By integrating spatially separated interdigitated working electrodes with selective self‐assembled monolayer (SAM) removal, the system enables target‐induced release and recapture of methylene blue‐labeled complementary DNA (MB‐cDNA) probes across two electrodes. This configuration minimizes background interference and enhances mass transport, facilitating robust dual‐channel signal transduction. The platform enables rapid (≤ 30 min), low‐volume (30 µL) detection of prototypical small molecules, dopamine and cortisol, in diverse biofluids, including artificial cerebrospinal fluid (aCSF), human serum, and saliva. Notably, the signal conversion mechanism remained effective across different targets and sample types, requiring only minimal adaptation of the recognition sequence. Together, these features establish a versatile electrochemical sensing architecture with broad potential for rapid, quantitative small‐molecule analysis in complex biological media.


  • Open Access

    Inkjet-Printed 3D Sensor Arrays with FIB-Induced Electrode Refinement for Low-Noise Amperometric Recordings in hiPSC-Derived Brain Organoids

    by Inola Kopic, Hu Peng, Sebastian Schmidt, Oleksandr Berezin, Senyao Wang, Gil G. Westmeyer, Bernhard Wolfrum

    Understanding the functional connectivity and behavior of 3D cell cultures and organoids requires monitoring electrical activity across multiple planes. However, traditional planar microelectrode arrays (MEAs) are limited to surface recordings and struggle to capture signals from deeper layers. Additionally, current fabrication methods face challenges such as prolonged production times and limited design flexibility, which hinder the development of high-precision 3D electrode arrays and affect the quality of cell-electrode coupling. To overcome these obstacles, we introduce a new approach that integrates inkjet printing with focused ion beam (FIB) milling and electrodeposition, resulting in highly customizable 3D MEAs. The FIB milling enables the creation of precise electrode openings at predetermined locations, which is essential for selective recordings within the tissue. The MEAs, fabricated on glass substrates, incorporate high-aspect-ratio (up to 44:1) electrode structures with heights up to 1 mm, a pitch of 500 μm, and electrode openings of 3 and 6 μm, providing the necessary resolution for targeted measurements. Impedance and noise characteristics (down to a root-mean-square of (RMS) noise of 0.2 pA) for amperometric measurements were assessed in dependence on the electrode size. We demonstrate the effectiveness of these 3D MEAs by recording electrophysiological activity from hiPSC-derived cortical organoids (age: 24 month) both in situ and after 10 days of cultivation of the organoid directly on the MEA. This approach facilitates in vitro studies of neural activity in organoids and holds promise for high-throughput, selective amperometric analyses in normal and pathologically altered conditions.


  • Functional‐Nanochannel‐Based Artificial Postsynaptic Membrane for Neural Signal Transduction

    by Senyao Wang, Wenyuan Zhang, Minghui Wu, Yitian Wu, Guoheng Xu, Wenchao Liu, Tingting Mei, Lu Chen, Kai Xiao

    Biological‐machine interface (BMI) devices represent a significant step toward adaptive and cognitive technologies. However, current BMI devices emphasize the analysis of electrophysiology and often overlook the chemical information of neurotransmitters in the process of signaling between neurons. To bridge this gap, a light‐gated artificial postsynaptic membrane (APM) is introduced, capable of reading dopamine (DA) released from rat pheochromocytoma cells and regulate neural signal transmission. Like the biological postsynaptic membrane, the APM is a porous membrane functionalized by DA‐specific aptamers and azobenzene (Azo) molecules in different regions. Azo molecules act as a light‐responsive trigger that controls DA release, while DA‐specific aptamers capture DA, which converts its concentration information into an ionic current signal. By light‐enhanced responses to DA exocytosis from rat pheochromocytoma (PC12) cells, the APM confirms its ability to communicate with biological systems, which lays the foundation for developing biological‐machine interaction systems with more advanced functionalities.


  • Top Cited Papers

    Bioinspired carbon nanotube–based nanofluidic ionic transistor with ultrahigh switching capabilities for logic circuits

    by Wenchao Liu, Tingting Mei, Zhouwen Cao, Chun Li, Yitian Wu, Li Wang, Guoheng Xu, Yuanxia Chen, You Zhou, Senyao Wang, et al.

    The voltage-gated ion channels, also known as ionic transistors, play substantial roles in biological systems and ion-ion selective separation. However, implementing the ultrafast switchable capabilities and polarity switching of ionic transistors remains a challenge. Here, we report a nanofluidic ionic transistor based on carbon nanotubes, which exhibits an on/off ratio of 10 4 at operational gate voltage as low as 1 V. By controlling the morphology of carbon nanotubes, both unipolar and ambipolar ionic transistors are realized, and their on/off ratio can be further improved by introducing an Al 2 O 3 dielectric layer. Meanwhile, this ionic transistor enables the polarity switching between p-type and n-type by controlled surface properties of carbon nanotubes. The implementation of constructing ionic circuits based on ionic transistors is demonstrated, which enables the creation of NOT, NAND, and NOR logic gates. The ionic transistors are expected to have profound implications for low-energy consumption computing devices and brain-machine interfacing.


  • Open Access

    A novel GBDT-BiLSTM hybrid model on improving day-ahead photovoltaic prediction

    by Senyao Wang, Jin Ma

    Despite being a clean and renewable energy source, photovoltaic (PV) power generation faces severe challenges in operation due to its strong intermittency and volatility compared to the traditional fossil fuel power generation. Accurate predictions are therefore crucial for PV’s grid connections and the system security. The existing methods often rely heavily on weather forecasts, the accuracy of which is hard to be guaranteed. This paper proposes a novel GBDT-BiLSTM day-ahead PV forecasting model, which leverages the Teacher Forcing mechanism to combine the strong time-series processing capabilities of BiLSTM with an enhanced GBDT model. Given the uncertainty and volatility inherent in solar energy and weather conditions, the gradient boosting method is employed to update the weak learner, while a decision tree is incorporated to update the strong learner. Additionally, to explore the correlation between photovoltaic power output and historical time-series data, the adaptive gradient descent-based Adam algorithm is utilized to train the bidirectional LSTM model, enhancing the accuracy and stability of mid- to long-term time-series predictions. A prediction experiment, conducting with the real data from a PV power station in Sichuan Province, China, was compared with other methods to verify the model’s effectiveness and robustness.


  • Triple-Helix Molecular Switch Triggered Cleavage Effect of DNAzyme for Ultrasensitive Electrochemical Detection of Chloramphenicol

    by Senyao Wang, Baoshan He, Wenjie Ren, Zhiguang Suo, Yiwei Xu, Min Wei, Huali Jin

    The abuse of chloramphenicol (CAP) in animal-derived products leads to serious food safety problems, so the sensitive and accurate determination of CAP residues has great noteworthiness for public health. Herein, we present a novel electrochemical aptasensor that incorporates a poly(diallyldimethylammonium chloride) functionalized graphene/Ag@Au nanosheets (PDDA-Gr/Ag@Au NSs) composite modified electrode and a DNAzyme signal amplification effect triggered by a triple-helix molecular switch (THMS) for detecting CAP. The PDDA-Gr/Ag@Au NSs composite has the advantages of high surface area, great conductivity, and dispersibility and has successfully improved the electrochemical performance of the electrode. Specific interaction with CAP will cause the signal transduction probe (STP) to be released from the THMS. After that, the DNAzyme will be activated with the help of Pb2+ and remove the immobilized signal probe on the electrode surface. The signal change was recorded by square wave voltammetry (SWV) and led to an accurate quantification of CAP. With all these features, the proposed sensing strategy yielded a satisfactory analytical performance with linearity between 1 pM and 1 μM and a limit of detection of 18.6 fM. Furthermore, the aptasensor shows excellent specificity for CAP in the presence of other antibiotics and resists interference with other common metal ions. Importantly, the performance is not diminished when the constructed aptasensor is applied to measuring CAP in milk powder. This THMS-based method is easy to design, and alteration to different targets can be achieved by simply replacing the aptamer sequence in the THMS. Therefore, this method shows significant prospects as a flexible platform for accurate monitoring of antibiotic residues in foodstuffs.