Jigang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jigang Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Baogen Sun
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
4 shared publications - Fangfang Wu
University of Science and Technology of China No. 42, Hezhou South Road
4 shared publications - Sanshuang Jin
National Synchrotron Radiation Laboratory (NSRL), University of Science and Technology of China (USTC) , No. 96, JinZhai Road Baohe District, Hefei, Anhui 230026, China
3 shared publications Sanshuang Jin
University of Science and Technology of China,National Synchrotron Radiation Laboratory,Hefei,China
2 shared publicationsTianyu Zhou
University of Science and Technology of China,National Synchrotron Radiation Laboratory,Hefei,China
2 shared publications- Tianyu Zhou
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
2 shared publications
Latest Publications
- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 27 (1) , 37-42
Two-Dimensional Visible Synchrotron Radiation Interferometry for Measuring Transverse Beam-Profile at HLS-II
Accurate measurement of the transverse beam-profile is critical to analyzing the performance of the electron storage ring light sources. In this paper, a two-dimensional interferometer using the spatial coherence of the synchrotron radiation is developed to measure the transverse beam-profile of Hefei Light Source-II (HLS-II). On the B7 beamline, the transverse beam-profile of this light source point was measured by the interference fringes of Synchrotron Radiation (SR) with wavelength of 500 nm. Under the normal top-off operation mode of HLS-II, the horizontal and vertical beam sizes measured by the interferometer are $291.9\pm 1.6\ \mu\mathrm{m}$ and $241.3\pm 0.9\ \mu\mathrm{m}$ , respectively. At the same time, the effect of beam intensity on the transverse beam-profile was also investigated. The interferometer measurement system we designed satisfies the real-time online monitoring of the transverse beam-profile in the top-off operation mode of HLS-II.- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 27 (1) , 37-42
Two-Dimensional Visible Synchrotron Radiation Interferometry for Measuring Transverse Beam-Profile at HLS-II
Accurate measurement of the transverse beam-profile is critical to analyzing the performance of the electron storage ring light sources. In this paper, a two-dimensional interferometer using the spatial coherence of the synchrotron radiation is developed to measure the transverse beam-profile of Hefei Light Source-II (HLS-II). On the B7 beamline, the transverse beam-profile of this light source point was measured by the interference fringes of Synchrotron Radiation (SR) with wavelength of 500 nm. Under the normal top-off operation mode of HLS-II, the horizontal and vertical beam sizes measured by the interferometer are $291.9\pm 1.6\ \mu\mathrm{m}$ and $241.3\pm 0.9\ \mu\mathrm{m}$ , respectively. At the same time, the effect of beam intensity on the transverse beam-profile was also investigated. The interferometer measurement system we designed satisfies the real-time online monitoring of the transverse beam-profile in the top-off operation mode of HLS-II.- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Estimations of Longitudinal Impedances Based on Temporal Beam Characteristic Parameter Extraction Method in Storage Ring Light Source
In this study, a simple suitable temporal beam characteristic parameter extraction method is developed to measure the longitudinal coupling impedance of the Hefei Light Source-II (HLS-II). In the experiment, a streak camera is applied to observe the potential-well distortion under single-bunch operation mode and then accurately measure the longitudinal impedance of machine. According to the theoretical analytical model and in combination with the measured longitudinal bunch behaviors, the inductive, resistive, and longitudinal broadband impedance of the HLS-II storage ring are obtained as 107±28 nH, 1430±242 Ω, and 1.009±0.013 Ω respectively, for the normal operating radio-frequency (RF) accelerating voltage of 122.8 kV. It is concluded that the effective longitudinal coupling impedance of HLS-II is calculated to be 3.05±0.80 Ω. Additionally, the bunch lengthening factor Bl and asymmetry factor A of longitudinal bunch distribution are also measured experimentally in various RF voltages so as to further research nonlinear longitudinal beam dynamics and beam evolution associated with bunch behaviors. Then, the applicability, feasibility and reliability of this proposed method are also verified. When the RF voltage is adjusted to 100.4, 110.3, 130.4, and 140.5 kV, the inductive impedance of machine is estimated to be 115±13, 107±17, 105±31, and 108±28 nH, respectively. And the according resistive impedance is 1320±310, 1380±214, 1360±230, and 1300±260 Ω, respectively. Through a series of experimental measurements, it has demonstrated the validity and accuracy of the measured longitudinal impedances of HLS-II, of which agree well with the simulated results.
- 13 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Estimations of Longitudinal Impedances Based on Temporal Beam Characteristic Parameter Extraction Method in Storage Ring Light Source
In this study, a simple suitable temporal beam characteristic parameter extraction method is developed to measure the longitudinal coupling impedance of the Hefei Light Source-II (HLS-II). In the experiment, a streak camera is applied to observe the potential-well distortion under single-bunch operation mode and then accurately measure the longitudinal impedance of machine. According to the theoretical analytical model and in combination with the measured longitudinal bunch behaviors, the inductive, resistive, and longitudinal broadband impedance of the HLS-II storage ring are obtained as 107±28 nH, 1430±242 Ω, and 1.009±0.013 Ω respectively, for the normal operating radio-frequency (RF) accelerating voltage of 122.8 kV. It is concluded that the effective longitudinal coupling impedance of HLS-II is calculated to be 3.05±0.80 Ω. Additionally, the bunch lengthening factor Bl and asymmetry factor A of longitudinal bunch distribution are also measured experimentally in various RF voltages so as to further research nonlinear longitudinal beam dynamics and beam evolution associated with bunch behaviors. Then, the applicability, feasibility and reliability of this proposed method are also verified. When the RF voltage is adjusted to 100.4, 110.3, 130.4, and 140.5 kV, the inductive impedance of machine is estimated to be 115±13, 107±17, 105±31, and 108±28 nH, respectively. And the according resistive impedance is 1320±310, 1380±214, 1360±230, and 1300±260 Ω, respectively. Through a series of experimental measurements, it has demonstrated the validity and accuracy of the measured longitudinal impedances of HLS-II, of which agree well with the simulated results.
- Open Access
- 4 May 2022
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 16 (1) , 18-28
Design of an interference system for measuring the transverse beam size in HLS-II
In this paper, a horizontal and vertical double-slits interferometer using visible light are designed to measure the transverse beam size of Hefei Light Source II (HLS-II). For the given initial structural parameters of the two interferometers, a series of numerical simulations and analyses are carried out by using the Synchrotron Radiation Workshop (SRW) code. Furthermore, the core parameters of the double-slits components in the interferometers are optimized. In the end, the visibilities of the horizontal and vertical interferometer we designed are 0.345 and 0.548 respectively, which are in the range of 0.2–0.6. And simulation results meet the requirement of theoretical relative measurement error of less than 10%.
- 4 May 2022
- Published by Taylor & Francis in International Journal of Optomechatronics
- Vol. 16 (1) , 18-28
Open AccessDesign of an interference system for measuring the transverse beam size in HLS-II
In this paper, a horizontal and vertical double-slits interferometer using visible light are designed to measure the transverse beam size of Hefei Light Source II (HLS-II). For the given initial structural parameters of the two interferometers, a series of numerical simulations and analyses are carried out by using the Synchrotron Radiation Workshop (SRW) code. Furthermore, the core parameters of the double-slits components in the interferometers are optimized. In the end, the visibilities of the horizontal and vertical interferometer we designed are 0.345 and 0.548 respectively, which are in the range of 0.2–0.6. And simulation results meet the requirement of theoretical relative measurement error of less than 10%.
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 196-979
A quad-slits interferometer for the transverse beam-profile measurement at HLS-II
A quad-slits interferometer using visible light is designed to measure the transverse beam-profile of Hefei Light SourceII (HLS-II). On the basis of the basic beam parameters of the B7 source point, the preliminary simulation results are obtained by using the Synchrotron Radiation Workshop (SRW) code. In addition, the core parameters of the quad-slits component in the interferometer are further optimized.
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 196-979
A quad-slits interferometer for the transverse beam-profile measurement at HLS-II
A quad-slits interferometer using visible light is designed to measure the transverse beam-profile of Hefei Light SourceII (HLS-II). On the basis of the basic beam parameters of the B7 source point, the preliminary simulation results are obtained by using the Synchrotron Radiation Workshop (SRW) code. In addition, the core parameters of the quad-slits component in the interferometer are further optimized.
- Open Access
Design of a Pre-Bunched THz Free Electron Laser
Terahertz (THz) radiation has attracted much attention in new scientific and industrial applications. There has been significant recent progress in generating THz with accelerators. To investigate the collective behavior of electron dynamics, we have proposed a new high throughput material characterization system, which supplies a multiple light source. The system includes a pre-bunched THz free electron laser (FEL), which is a high-power narrow-band THz source with a wide tuning range of frequency. The physical design with the main components of the facility is introduced, and the simulation results are illustrated. Radiation of 0.5–3.0 THz is obtained by the fundamental wave of the pre-bunched beam, and radiation covering 3.0–5.0 THz is realized by second harmonic generation. As the simulation shows, intense THz radiation could be achieved in a frequency from 0.5–5.0 THz, with a peak power of several megawatts (MWs) and a bandwidth of a few percent.
Open AccessDesign of a Pre-Bunched THz Free Electron Laser
Terahertz (THz) radiation has attracted much attention in new scientific and industrial applications. There has been significant recent progress in generating THz with accelerators. To investigate the collective behavior of electron dynamics, we have proposed a new high throughput material characterization system, which supplies a multiple light source. The system includes a pre-bunched THz free electron laser (FEL), which is a high-power narrow-band THz source with a wide tuning range of frequency. The physical design with the main components of the facility is introduced, and the simulation results are illustrated. Radiation of 0.5–3.0 THz is obtained by the fundamental wave of the pre-bunched beam, and radiation covering 3.0–5.0 THz is realized by second harmonic generation. As the simulation shows, intense THz radiation could be achieved in a frequency from 0.5–5.0 THz, with a peak power of several megawatts (MWs) and a bandwidth of a few percent.
- Open Access
- p. 1942-1944
Application and Development of the Streak Camera Measurement System at HLS-II
- p. 1942-1944
Open AccessApplication and Development of the Streak Camera Measurement System at HLS-II