Rosepon Asawaworarit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rosepon Asawaworarit has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Krit Pongpirul
Center of Excellence in Preventive and Integrative Medicine (CE-PIM), Faculty of Medicine, Chulalongkorn University
1 shared publication - Luksanaporn Krungkraipetch
Department of Ophthalmology, Faculty of Medicine, Burapha University, Chonburi, Thailand
1 shared publication - Nattawat Asawaworarit
Department of Ophthalmology, Faculty of Medicine, Burapha University, Chonburi
1 shared publication Pakaphan Dinchuthai
Department of Internal Medicine, Faculty of Medicine, Burapha University, Chonburi
1 shared publicationParichart Taweekitikul
Affiliation Department of Ophthalmology, Faculty of Medicine, Excellence Center for Cornea and Limbal Stem Cell Transplantation, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok, Thailand
1 shared publication- Vannarut Satitpitakul
Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 15 July 2026
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 21, 1-9
Comparison of Clinical Outcomes Between Femtosecond Laser-assisted Cataract Surgery and Phacoemulsification in Patients with Diabetes: A Systematic Review
This article systematically review and compare the efficacy and safety of femtosecond laserassisted cataract surgery (FLACS) and traditional phacoemulsification (PE) in patients with diabetes. A systematic search was conducted in Scopus, PubMed, Cochrane Library, and Google Scholar from inception to December 2024. Studies comparing FLACS with PE in patients with diabetes were included. The primary outcomes were central corneal thickness (CCT) and endothelial cell density (ECD), while the secondary outcomes included effective phaco time (EPT), surgical complications, and visual outcomes. The Cochrane Risk of Bias Tool 2.0 was used to assess quality in randomized controlled trials (RCTs), ROBINS-I for cohort studies, and the Newcastle-Ottawa scale for retrospective studies. Six studies involving 345 eyes met the inclusion criteria: one RCT, two cohort studies, one prospective study, and two retrospective studies. In the RCT, FLACS demonstrated significantly higher postoperative ECD compared to PE (mean difference: 423.55 cells/mm²; 95% CI: 199.89 to 647.21; P < 0.001). One cohort study reported EPT values of 6.52 ± 4.93 seconds for FLACS and 5.63 ± 4.31 seconds for PE. No significant differences in CCT were observed between groups at 3 months postoperatively across multiple studies. One study reported a lower incidence of postoperative complications, including fibrin exudation, corneal edema, posterior synechiae, and pigment dispersion, in the FLACS group, although specific rates were not provided. Overall, FLACS demonstrated superior endothelial cell preservation and a favorable safety profile in patients with diabetes; however, the available evidence is limited by study heterogeneity and risk of bias. Large-scale randomized controlled trials with standardized outcome reporting are needed.
- 15 July 2026
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 21, 1-9
Open AccessComparison of Clinical Outcomes Between Femtosecond Laser-assisted Cataract Surgery and Phacoemulsification in Patients with Diabetes: A Systematic Review
This article systematically review and compare the efficacy and safety of femtosecond laserassisted cataract surgery (FLACS) and traditional phacoemulsification (PE) in patients with diabetes. A systematic search was conducted in Scopus, PubMed, Cochrane Library, and Google Scholar from inception to December 2024. Studies comparing FLACS with PE in patients with diabetes were included. The primary outcomes were central corneal thickness (CCT) and endothelial cell density (ECD), while the secondary outcomes included effective phaco time (EPT), surgical complications, and visual outcomes. The Cochrane Risk of Bias Tool 2.0 was used to assess quality in randomized controlled trials (RCTs), ROBINS-I for cohort studies, and the Newcastle-Ottawa scale for retrospective studies. Six studies involving 345 eyes met the inclusion criteria: one RCT, two cohort studies, one prospective study, and two retrospective studies. In the RCT, FLACS demonstrated significantly higher postoperative ECD compared to PE (mean difference: 423.55 cells/mm²; 95% CI: 199.89 to 647.21; P < 0.001). One cohort study reported EPT values of 6.52 ± 4.93 seconds for FLACS and 5.63 ± 4.31 seconds for PE. No significant differences in CCT were observed between groups at 3 months postoperatively across multiple studies. One study reported a lower incidence of postoperative complications, including fibrin exudation, corneal edema, posterior synechiae, and pigment dispersion, in the FLACS group, although specific rates were not provided. Overall, FLACS demonstrated superior endothelial cell preservation and a favorable safety profile in patients with diabetes; however, the available evidence is limited by study heterogeneity and risk of bias. Large-scale randomized controlled trials with standardized outcome reporting are needed.
- Open Access
- 24 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0268856
Agreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients
Purpose: To evaluate agreement of total corneal power (TCP) measured by swept-source anterior segment optical coherence tomography (CASIA 2), Scheimpflug tomography (Pentacam AXL), and swept-source optical biometer (IOLMaster 700) in normal and keratoconic patients. Methods: This is a prospective observational study conducted at King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Biometric values were measured by each device for three times by two operators to evaluate repeatability and reproducibility of TCP. The agreement of TCP and other parameters including total corneal astigmatism, anterior keratometry, anterior corneal astigmatism, posterior keratometry, posterior corneal astigmatism, anterior chamber depth, white-to-white corneal diameter (WTW), central corneal thickness, and intraocular power were also evaluated. Results: This study enrolled 100 healthy participants and 34 patients with keratoconus. The repeatability and reproducibility of TCP were high in all devices (ICC > 0.9). The agreement of TCP was excellent among three devices in both groups (ICC > 0.9). However, the agreement of TCP between CASIA 2 and IOLMaster 700 was slightly lower in healthy participants (ICC = 0.867) and keratoconic patients (ICC = 0.852) with mean differences of more than 1.0 diopter is clinically significant. Wider 95% limit of agreement were found in keratoconic eyes. Most of other parameters showed good to excellent agreement except WTW which showed poor to moderate agreement in both groups. IOL power showed clinically significant differences in patients with keratoconus. Conclusions: The agreement of TCP measured by three devices was excellent in normal and keratoconic patients. However, TCP cannot be used interchangeably between devices.
- 24 May 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (5) , e0268856
Open AccessAgreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients
Purpose: To evaluate agreement of total corneal power (TCP) measured by swept-source anterior segment optical coherence tomography (CASIA 2), Scheimpflug tomography (Pentacam AXL), and swept-source optical biometer (IOLMaster 700) in normal and keratoconic patients. Methods: This is a prospective observational study conducted at King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Biometric values were measured by each device for three times by two operators to evaluate repeatability and reproducibility of TCP. The agreement of TCP and other parameters including total corneal astigmatism, anterior keratometry, anterior corneal astigmatism, posterior keratometry, posterior corneal astigmatism, anterior chamber depth, white-to-white corneal diameter (WTW), central corneal thickness, and intraocular power were also evaluated. Results: This study enrolled 100 healthy participants and 34 patients with keratoconus. The repeatability and reproducibility of TCP were high in all devices (ICC > 0.9). The agreement of TCP was excellent among three devices in both groups (ICC > 0.9). However, the agreement of TCP between CASIA 2 and IOLMaster 700 was slightly lower in healthy participants (ICC = 0.867) and keratoconic patients (ICC = 0.852) with mean differences of more than 1.0 diopter is clinically significant. Wider 95% limit of agreement were found in keratoconic eyes. Most of other parameters showed good to excellent agreement except WTW which showed poor to moderate agreement in both groups. IOL power showed clinically significant differences in patients with keratoconus. Conclusions: The agreement of TCP measured by three devices was excellent in normal and keratoconic patients. However, TCP cannot be used interchangeably between devices.