Lih-Seng Yeh
Lih-Seng Yeh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
C. H. Huang
Institute of Veterinary Clinical Sciences, School of Veterinary Medicine, National Taiwan University, No. 1, Sec 4, Roosevelt Rd., Taipei, 106, Taiwan
1 shared publicationChao-Chang Chen
Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
1 shared publication- Cheng-Chung Lin
Department of Electrical Engineering, Fu Jen Catholic University, New Taipei City, Taiwan
1 shared publication Chi-Yuan Ho
Section of Small Animal Surgery, National Taiwan University Veterinary Hospital, Taipei, Taiwan
1 shared publication- Chia-Chi Kuo
Department of Nursing, Chang Gung University of Science and Technology, Chiayi Campus, Taiwan, ROC.
1 shared publication - Chih-Cheng Chen
School of Medicine, College of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan; Department of Oncology, Taipei Veterans General Hospital, Taipei, Taiwan
1 shared publication
Latest Publications
- 17 May 2022
- Published by Wiley in Veterinary Record Case Reports
- Vol. 10 (3)
Latex bag contrast system for the diagnosis of oesophageal and rectal strictures in two cats
A common problem we often encounter during traditional contrast radiography is that contrast media are not adequately retained in the target region, especially during oesophagography and proctography. Patients with oesophageal disorders often have dysphagia or regurgitation, which increase the risk of aspiration pneumonia. Stercoroma in patients with rectal disease often prevents clinicians from obtaining good‐quality proctography for diagnosis. In the present case report, we introduce a novel contrast diagnostic system that has been used to diagnose oesophageal and rectal strictures. Latex bags (commercial latex condoms) are thin with good elasticity, producing a delicate interface for contrast filling, thereby providing better image quality. The watertight design of the latex bag system facilitates the retrieval of contrast media after radiographic examination. Furthermore, it significantly decreases the risk of aspiration pneumonia during the diagnostic process.
- 17 May 2022
- Published by Wiley in Veterinary Record Case Reports
- Vol. 10 (3)
Latex bag contrast system for the diagnosis of oesophageal and rectal strictures in two cats
A common problem we often encounter during traditional contrast radiography is that contrast media are not adequately retained in the target region, especially during oesophagography and proctography. Patients with oesophageal disorders often have dysphagia or regurgitation, which increase the risk of aspiration pneumonia. Stercoroma in patients with rectal disease often prevents clinicians from obtaining good‐quality proctography for diagnosis. In the present case report, we introduce a novel contrast diagnostic system that has been used to diagnose oesophageal and rectal strictures. Latex bags (commercial latex condoms) are thin with good elasticity, producing a delicate interface for contrast filling, thereby providing better image quality. The watertight design of the latex bag system facilitates the retrieval of contrast media after radiographic examination. Furthermore, it significantly decreases the risk of aspiration pneumonia during the diagnostic process.
- 1 September 2021
- Published by World Scientific Pub Co Pte Ltd in Taiwan Veterinary Journal
- Vol. 47 (03n04) , 43-47
A STUDY OF WARMING DEVICES AND PERIOPERATIVE FACTORS POTENTIALLY CONTRIBUTING TO SURGICAL FIELD CONTAMINATION IN SMALL ANIMAL PATIENTS
- 1 September 2021
- Published by World Scientific Pub Co Pte Ltd in Taiwan Veterinary Journal
- Vol. 47 (03n04) , 43-47
A STUDY OF WARMING DEVICES AND PERIOPERATIVE FACTORS POTENTIALLY CONTRIBUTING TO SURGICAL FIELD CONTAMINATION IN SMALL ANIMAL PATIENTS
- 3 May 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (03) , 182-187
Biomechanical Comparison between Preloaded Position Screw and Lag Screw Fixations for Their Compressive Effects in a Porcine Rib Fracture Model
Objectives The aim of this study was to compare the compressive effect between preloaded position screws and lag screws in fracture fixation. Methods Pairs of semi-cylindrical bone fragments were created on a porcine rib model to simulate fractured bones. The compressive forces of fracture fixation generated by preloaded position screws (P group) and conventional lag screws (L group) were recorded by a film stress sensor. In the P group, a pair of Angus bone holding forceps was used to compress the interfragmentary interface until reaching the preloading force of 1.3 MPa. Similar preloading procedure was applied on lag screw fixations to explore its potential of additional compressive force. Results With 1.3 MPa preloading force and 0.2 Nm screw insertion torque force, the interfragmentary compressive force of P group was similar to that of L group. When the insertion torque force was increased to 0.4 Nm, all screws in the L group failed due to thread stripping. When screws in the P group were installed under 0.4 Nm torque and in the L group under 0.2 Nm torque, the P group generated significantly greater compressive force. With preloading device applied on lag screw installation, it did not further increase the interfragmentary compressive force. Clinical Significance Compared with lag screws, preloaded position screws tolerated greater torque in screw installation and provided greater interfragmentary compressive force. The study suggests the applicability of preloaded position screws in fracture fixation requiring interfragmentary compression. * Both authors contributed equally to this work.
- 3 May 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (03) , 182-187
Biomechanical Comparison between Preloaded Position Screw and Lag Screw Fixations for Their Compressive Effects in a Porcine Rib Fracture Model
Objectives The aim of this study was to compare the compressive effect between preloaded position screws and lag screws in fracture fixation. Methods Pairs of semi-cylindrical bone fragments were created on a porcine rib model to simulate fractured bones. The compressive forces of fracture fixation generated by preloaded position screws (P group) and conventional lag screws (L group) were recorded by a film stress sensor. In the P group, a pair of Angus bone holding forceps was used to compress the interfragmentary interface until reaching the preloading force of 1.3 MPa. Similar preloading procedure was applied on lag screw fixations to explore its potential of additional compressive force. Results With 1.3 MPa preloading force and 0.2 Nm screw insertion torque force, the interfragmentary compressive force of P group was similar to that of L group. When the insertion torque force was increased to 0.4 Nm, all screws in the L group failed due to thread stripping. When screws in the P group were installed under 0.4 Nm torque and in the L group under 0.2 Nm torque, the P group generated significantly greater compressive force. With preloading device applied on lag screw installation, it did not further increase the interfragmentary compressive force. Clinical Significance Compared with lag screws, preloaded position screws tolerated greater torque in screw installation and provided greater interfragmentary compressive force. The study suggests the applicability of preloaded position screws in fracture fixation requiring interfragmentary compression. * Both authors contributed equally to this work.
- 22 August 2017
- Published by Wiley in Veterinary Surgery
- Vol. 46 (8) , 1116-1119
A vascularized preputial free flap for labial reconstruction in a dog
Objective: To describe the clinical application of a vascularized preputial free flap in the reconstruction of a large facial‐labial defect.Study design: Case report.Animals: An adult neutered male mongrel dog with a large left facial‐labial defect.Methods: A preputial free flap was created by elevating the cranial part of the prepuce, using the ipsilateral caudal superficial epigastric vessels as a vascular pedicle. The flap was transferred to the facial‐labial defect and the donor vessels anastomosed to the sublingual artery and vein, using standard microvascular technique.Results: The free flap survived, leading to good cosmetic and functional outcomes. No major complications were encountered at either the donor or recipient sites after 2 years of follow‐up.Conclusion: Vascularized preputial free flaps can be used to manage composite facial and oral cavity defects involving large areas of skin and mucosa.
- 22 August 2017
- Published by Wiley in Veterinary Surgery
- Vol. 46 (8) , 1116-1119
A vascularized preputial free flap for labial reconstruction in a dog
Objective: To describe the clinical application of a vascularized preputial free flap in the reconstruction of a large facial‐labial defect.Study design: Case report.Animals: An adult neutered male mongrel dog with a large left facial‐labial defect.Methods: A preputial free flap was created by elevating the cranial part of the prepuce, using the ipsilateral caudal superficial epigastric vessels as a vascular pedicle. The flap was transferred to the facial‐labial defect and the donor vessels anastomosed to the sublingual artery and vein, using standard microvascular technique.Results: The free flap survived, leading to good cosmetic and functional outcomes. No major complications were encountered at either the donor or recipient sites after 2 years of follow‐up.Conclusion: Vascularized preputial free flaps can be used to manage composite facial and oral cavity defects involving large areas of skin and mucosa.
- 1 December 2014
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 26 (06) , 1450076
EFFECTS OF PELVIC AND FEMORAL POSITIONING ON CANINE NORBERG ANGLE MEASUREMENTS AND TEST–RETEST RELIABILITY: A COMPUTED TOMOGRAPHY-BASED SIMULATION STUDY
Canine hip dysplasia is a common disease in dogs, often diagnosed by using the Norberg angle (NA), an index for the laxity of the hip joint. Measurement of the NA can be affected by the pelvic and femoral positioning during imaging, the effects and test–retest reliability of which have not been documented. To bridge the gap in knowledge, computed tomography data from 11 Labrador Retriever dogs were obtained and used to generate synthetic ventrodorsal radiographs of the hip for NA measurements via a perspective projection model. Twenty-five synthetic radiographs of the hips were generated at positions defined by combinations of five pelvic tilt angles (-20° to 20° at 10° intervals) and five femoral elevation angles (from full extension to 40° at 10° intervals). For each radiograph, the NA was measured three times by each of the two experienced veterinarian examiners. It was found that both the increase in caudal pelvic tilt and femoral elevation increased the measured NA, although the intra- and inter-examiner reliability was very good for a given hip position. The current results suggest that careful positioning of the pelvis and femur during radiographic imaging is critical for accurately measuring the NA, and thus the laxity of the hip, for the clinical diagnosis of hip dysplasia.
- 1 December 2014
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 26 (06) , 1450076
EFFECTS OF PELVIC AND FEMORAL POSITIONING ON CANINE NORBERG ANGLE MEASUREMENTS AND TEST–RETEST RELIABILITY: A COMPUTED TOMOGRAPHY-BASED SIMULATION STUDY
Canine hip dysplasia is a common disease in dogs, often diagnosed by using the Norberg angle (NA), an index for the laxity of the hip joint. Measurement of the NA can be affected by the pelvic and femoral positioning during imaging, the effects and test–retest reliability of which have not been documented. To bridge the gap in knowledge, computed tomography data from 11 Labrador Retriever dogs were obtained and used to generate synthetic ventrodorsal radiographs of the hip for NA measurements via a perspective projection model. Twenty-five synthetic radiographs of the hips were generated at positions defined by combinations of five pelvic tilt angles (-20° to 20° at 10° intervals) and five femoral elevation angles (from full extension to 40° at 10° intervals). For each radiograph, the NA was measured three times by each of the two experienced veterinarian examiners. It was found that both the increase in caudal pelvic tilt and femoral elevation increased the measured NA, although the intra- and inter-examiner reliability was very good for a given hip position. The current results suggest that careful positioning of the pelvis and femur during radiographic imaging is critical for accurately measuring the NA, and thus the laxity of the hip, for the clinical diagnosis of hip dysplasia.
- 1 November 2013
- Published by Elsevier in Veterinary Anaesthesia and Analgesia
- Vol. 40 (6) , 615-622
Comparison of postoperative effects between lidocaine infusion, meloxicam, and their combination in dogs undergoing ovariohysterectomy
- 1 November 2013
- Published by Elsevier in Veterinary Anaesthesia and Analgesia
- Vol. 40 (6) , 615-622
Comparison of postoperative effects between lidocaine infusion, meloxicam, and their combination in dogs undergoing ovariohysterectomy
- 1 October 2013
- Published by American Scientific Publishers in Journal of Neuroscience and Neuroengineering
- Vol. 2 (5) , 460-464
Minimally Invasive Cannula Approach for Lumbar Decompression: An Innovative Technique in a Canine Model
Herniation of the intervertebral disc is a common cause of spinal cord dysfunction in mammals. However, the procedures for studying herniation in animal experiments are not well established. This study aimed to apply an innovative technique to study spinal cord dysfunction using a canine model. A commonly available 3-mL syringe barrel was used as a cannula sheath, and all surgical tools were inserted and manipulated through the space remaining within the sheath. The study was completed with four dogs; each dog was tested at the L1/L2 and L3/L4 levels on the left side. The procedures of hemilaminectomy, facectomy, and discectomy were performed. The operating time varied between 85 and 280 minutes. The learning curve showed a reduction of the operating time from 280 minutes during the first procedure to 100 minutes during the fifth procedure. The newly developed sheath is inexpensive, disposable, and easy to use, and it can facilitate microscopic surgery. In the future, a clinical study of these surgical procedures is required. In experienced hands, such a technique is as effective as traditional lumbar discectomy and decreases traumatizing the normal anatomy of the dorsal musculature and ligamentous structures.
- 1 October 2013
- Published by American Scientific Publishers in Journal of Neuroscience and Neuroengineering
- Vol. 2 (5) , 460-464
Minimally Invasive Cannula Approach for Lumbar Decompression: An Innovative Technique in a Canine Model
Herniation of the intervertebral disc is a common cause of spinal cord dysfunction in mammals. However, the procedures for studying herniation in animal experiments are not well established. This study aimed to apply an innovative technique to study spinal cord dysfunction using a canine model. A commonly available 3-mL syringe barrel was used as a cannula sheath, and all surgical tools were inserted and manipulated through the space remaining within the sheath. The study was completed with four dogs; each dog was tested at the L1/L2 and L3/L4 levels on the left side. The procedures of hemilaminectomy, facectomy, and discectomy were performed. The operating time varied between 85 and 280 minutes. The learning curve showed a reduction of the operating time from 280 minutes during the first procedure to 100 minutes during the fifth procedure. The newly developed sheath is inexpensive, disposable, and easy to use, and it can facilitate microscopic surgery. In the future, a clinical study of these surgical procedures is required. In experienced hands, such a technique is as effective as traditional lumbar discectomy and decreases traumatizing the normal anatomy of the dorsal musculature and ligamentous structures.
- 14 February 2013
- Published by Wiley in Anatomia, Histologia, Embryologia
- Vol. 42 (6) , 425-431
The Innervation of Canine Hip Joint Capsule: An Anatomic Study
Summary: To clarify the contributions of the nerves supplying the canine hip joint capsule for clinical application, cadaver study of six healthy mongrel dogs was performed. The pelvises and hindlimbs of cadavers were dissected and fixed in formaldehyde. Innervation of the joint capsule was investigated with the aid of an operative microscope. As a result, the canine hip joint capsule receives multiple innervations from articular branches of four nerves. They are articular nerve fibres of femoral, obturator, cranial gluteal and sciatic nerves from the cranioventral, caudoventral, craniolateral and dorsolateral directions of the joint, respectively. No branch originating from the caudal gluteal nerve was observed innervating the hip joint capsule. Our data provides useful information for research on the canine hip joint, including pain analysis with hip disorders and surgical nerve blockade to relieve pain.
- 14 February 2013
- Published by Wiley in Anatomia, Histologia, Embryologia
- Vol. 42 (6) , 425-431
The Innervation of Canine Hip Joint Capsule: An Anatomic Study
Summary: To clarify the contributions of the nerves supplying the canine hip joint capsule for clinical application, cadaver study of six healthy mongrel dogs was performed. The pelvises and hindlimbs of cadavers were dissected and fixed in formaldehyde. Innervation of the joint capsule was investigated with the aid of an operative microscope. As a result, the canine hip joint capsule receives multiple innervations from articular branches of four nerves. They are articular nerve fibres of femoral, obturator, cranial gluteal and sciatic nerves from the cranioventral, caudoventral, craniolateral and dorsolateral directions of the joint, respectively. No branch originating from the caudal gluteal nerve was observed innervating the hip joint capsule. Our data provides useful information for research on the canine hip joint, including pain analysis with hip disorders and surgical nerve blockade to relieve pain.