Tamer M. Elkhodragy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tamer M. Elkhodragy has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Alexey Pryakhin
1 shared publication- Gamal G. N. Geweid
Electrical Engineering Department, School of Electrical Engineering and Computer Science, University of North Dakota, ND 58202 USA and Electrical Engineering Department, Benha Faculty of Engineering, Benha University, Benha 13511Egypt
1 shared publication - Karar Mahmoud
Department of Electrical Engineering, Aswan University, Aswân, Egypt
1 shared publication M.A. Abdallah
1 shared publicationMahmoud El Bahy
Electrical Engineering Department, Faculty of Engineering, Benha University
1 shared publication- Manar A. Khalil
Department of Electrical Engineering, Benha Faculty of Engineering, Benha University, Benha, Egypt
1 shared publication
Latest Publications
- 3 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (1) , 1009-1034
A novel hybrid algorithm based on optimal size and location of photovoltaic with battery energy storage systems for voltage stability enhancement
- 3 July 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (1) , 1009-1034
A novel hybrid algorithm based on optimal size and location of photovoltaic with battery energy storage systems for voltage stability enhancement
- 1 March 2024
- Published by Egyptian Knowledge Bank in Fayoum University Journal of Engineering
- Vol. 7 (2) , 106-119
Optimization of Fault Diagnosis of Electrical Motors Using Adaptive Control Based on IOT Monitoring System
Induction motors are popular in industry due to their robustness, reliability, and low maintenance. Like all machines, they can fail and cause downtime, production losses, and safety hazards. Early detection and diagnosis of motor faults prevents catastrophic failures, reduces maintenance costs, and improves efficiency. This paper presents the feasibility and effectiveness of using vibra-tion, temperature, and current (VTC) measurements to obtain a comprehensive picture of the motor's condition and predict faults early. Internet of Things (IoT) sensors and adaptive control supervision protect induction motors by detecting and classifying faults in real-time based on experimental data obtained in the lab. This IoT system monitors and diagnoses electrical motor conditions by measuring VTC to predict functional abnormalities. Sensors are connected to a universal, low-cost microcontroller to obtain the required results. Data is stored on a cloud platform and accessed via a web dashboard and a smartphone application. An efficient adaptive control technique using Artificial Neural Network (ANN) learning identifies fault types even in uncertain diagnosis situ-ations. Simulation results demonstrate its effectiveness in diagnosing the target fault type among the three types. Overall, the paper's results prove that the pro-posed method improves the reliability and efficiency of motor systems by providing accurate fault diagnosis. This can result in significant economic and environmental benefits by reducing maintenance costs and preventing cata-strophic failures.
- 1 March 2024
- Published by Egyptian Knowledge Bank in Fayoum University Journal of Engineering
- Vol. 7 (2) , 106-119
Optimization of Fault Diagnosis of Electrical Motors Using Adaptive Control Based on IOT Monitoring System
Induction motors are popular in industry due to their robustness, reliability, and low maintenance. Like all machines, they can fail and cause downtime, production losses, and safety hazards. Early detection and diagnosis of motor faults prevents catastrophic failures, reduces maintenance costs, and improves efficiency. This paper presents the feasibility and effectiveness of using vibra-tion, temperature, and current (VTC) measurements to obtain a comprehensive picture of the motor's condition and predict faults early. Internet of Things (IoT) sensors and adaptive control supervision protect induction motors by detecting and classifying faults in real-time based on experimental data obtained in the lab. This IoT system monitors and diagnoses electrical motor conditions by measuring VTC to predict functional abnormalities. Sensors are connected to a universal, low-cost microcontroller to obtain the required results. Data is stored on a cloud platform and accessed via a web dashboard and a smartphone application. An efficient adaptive control technique using Artificial Neural Network (ANN) learning identifies fault types even in uncertain diagnosis situ-ations. Simulation results demonstrate its effectiveness in diagnosing the target fault type among the three types. Overall, the paper's results prove that the pro-posed method improves the reliability and efficiency of motor systems by providing accurate fault diagnosis. This can result in significant economic and environmental benefits by reducing maintenance costs and preventing cata-strophic failures.
- 20 December 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 244
Optimizing dialysis water treatment based on medical planning requirements
- 20 December 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 244
Optimizing dialysis water treatment based on medical planning requirements
- Open Access
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 53713-53723
Pollution Severity Monitoring of High Voltage Transmission Line Insulators Using Wireless Device Based on Leakage Current Bursts
The present article describes a smart wireless online device for the severity monitoring of the contaminated insulators of high voltage transmission networks. Accordingly, the wireless developed monitor works by continuously sensing the magnitudes of the leakage current bursts and calculating its average root-mean-square (RMS) value for every second or minute as the monitor software is calibrated. Regarding, if the average of the leakage current RMS value is adjudicated by the monitor as corresponding to a probably significant scale of a power outage, the monitor transfers an alarm signal and sends a warning message to the maintenance crew members to take the action to wash the high voltage line insulators on time before the unexpected outage of the high voltage network has been occurring. The developed monitor contains the following main units: current transformer with burden resistor, Node MCU (ESP8266), solar power bank, cloud-based data storage, and smart device (Mobile or tablet). These units can be assembled to work without the need for a power source. The proposed monitor has many merits over the other monitoring devices; it enjoys little cost, easy of handling, and calibration. It has a high degree of safety, it is an online system, and its design is simple. The developed monitor is tested in the Laboratory using insulators with different pollution layers’ conductivity and the findings show that the accuracy of the proposed monitor reached 91.66 % after carrying out 50 tests.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 53713-53723
Open AccessPollution Severity Monitoring of High Voltage Transmission Line Insulators Using Wireless Device Based on Leakage Current Bursts
The present article describes a smart wireless online device for the severity monitoring of the contaminated insulators of high voltage transmission networks. Accordingly, the wireless developed monitor works by continuously sensing the magnitudes of the leakage current bursts and calculating its average root-mean-square (RMS) value for every second or minute as the monitor software is calibrated. Regarding, if the average of the leakage current RMS value is adjudicated by the monitor as corresponding to a probably significant scale of a power outage, the monitor transfers an alarm signal and sends a warning message to the maintenance crew members to take the action to wash the high voltage line insulators on time before the unexpected outage of the high voltage network has been occurring. The developed monitor contains the following main units: current transformer with burden resistor, Node MCU (ESP8266), solar power bank, cloud-based data storage, and smart device (Mobile or tablet). These units can be assembled to work without the need for a power source. The proposed monitor has many merits over the other monitoring devices; it enjoys little cost, easy of handling, and calibration. It has a high degree of safety, it is an online system, and its design is simple. The developed monitor is tested in the Laboratory using insulators with different pollution layers’ conductivity and the findings show that the accuracy of the proposed monitor reached 91.66 % after carrying out 50 tests.