Judicael Aubry
Research Subjects
Judicael Aubry has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anne Blavette
SATIE, CNRS, France
1 shared publication - Bernard Multon
SATIE, ENS Rennes, University of Rennes, Bruz, France
1 shared publication D. Hissel
1 shared publication- Daniel Hissel
Université Marie et Louis Pasteur, UTBM, SupMicroTech-ENSMM, CNRS, Institut FEMTO-ST, FCLAB, 90000 Belfort, France
1 shared publication - Hamid Ben Ahmed
SATIE, CNRS, ENS Rennes, Université de Rennes, 35170 Bruz, France
1 shared publication Martin Serine
1 shared publication
Latest Publications
- Open Access
- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization of Operating Conditions for a PEMFC Automotive Stack Using Design of Experiments and a multi-factor ANOVA method
This paper provides a novel workflow for PEMFC performance enhancement through the Design of Experiment technique. A comparative study of multi-way ANOVAs is performed for operating factor screening, showing that reactant gas pressure explains more than 75% of cell voltage variations. A 2-hour testing time reduction is reached with the refinement of a 4-factors Box-Behnken test matrix. A polynomial model is developed and validated on a separate dataset. It catches operating condition quadratic effects on mean cell voltage response and has been extended to standard deviation prediction. The resulting response surface reveals the 60-mV potential gain on cell voltage and the 20% associated decrease of cell voltage dispersion among the stack at fixed current density. The obtained results pave the way for data-based model integration into fuel cell stack product development and industrialization.
- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization of Operating Conditions for a PEMFC Automotive Stack Using Design of Experiments and a multi-factor ANOVA method
This paper provides a novel workflow for PEMFC performance enhancement through the Design of Experiment technique. A comparative study of multi-way ANOVAs is performed for operating factor screening, showing that reactant gas pressure explains more than 75% of cell voltage variations. A 2-hour testing time reduction is reached with the refinement of a 4-factors Box-Behnken test matrix. A polynomial model is developed and validated on a separate dataset. It catches operating condition quadratic effects on mean cell voltage response and has been extended to standard deviation prediction. The resulting response surface reveals the 60-mV potential gain on cell voltage and the 20% associated decrease of cell voltage dispersion among the stack at fixed current density. The obtained results pave the way for data-based model integration into fuel cell stack product development and industrialization.
- Open Access
- 24 May 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 6687-6706
Fuel cell diagnosis methods for embedded automotive applications
- 24 May 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 6687-6706
Open AccessFuel cell diagnosis methods for embedded automotive applications
- Open Access
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Comparison between centralized and decentralized storage energy management for Direct Wave Energy Converter Farm
This article compares the sizes of an Energy Storage System (ESS) with two control types in order to smooth a Direct Wave Energy Converter (DWEC) Farm Production, namely a centralized one that deals with the PCC power and a decentralized one that deals with each unit power production. The main objective is to compare the two controls on the basis of their life cycle cost. The SEAREV project is the Direct Wave Energy Converter used as an example in this paper. The ESS is necessary for grid integration in the case considered here due to the flicker constraint, which is not being satisfied without storage. The optimization strategies for both the sizing and the management of an Energy Storage System (ESS) will be described: the rule-based energy management approach depends on the State of Energy of this ESS as well as the power produced by the DWEC unit or the DWEC farm. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost. The centralized control clearly allowed smaller capacity, but has some drawbacks for the losses in the rest of the farm.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Open AccessComparison between centralized and decentralized storage energy management for Direct Wave Energy Converter Farm
This article compares the sizes of an Energy Storage System (ESS) with two control types in order to smooth a Direct Wave Energy Converter (DWEC) Farm Production, namely a centralized one that deals with the PCC power and a decentralized one that deals with each unit power production. The main objective is to compare the two controls on the basis of their life cycle cost. The SEAREV project is the Direct Wave Energy Converter used as an example in this paper. The ESS is necessary for grid integration in the case considered here due to the flicker constraint, which is not being satisfied without storage. The optimization strategies for both the sizing and the management of an Energy Storage System (ESS) will be described: the rule-based energy management approach depends on the State of Energy of this ESS as well as the power produced by the DWEC unit or the DWEC farm. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost. The centralized control clearly allowed smaller capacity, but has some drawbacks for the losses in the rest of the farm.