ABAnne Kristine Brekka

Anne Kristine Brekka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anne Kristine Brekka has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Rehabilitation prescription tools in critical care: why reinvent the wheel?

    by Katrine Astrup, Charlotte Schanke, Helena Van Aswegen, Sabrina Eggmann, Anne Kristine Brekka, Frances Eriksson, Ulrika Holdar, Niamh O'SUllivan, Zoe van Willigen

  • Impact of laryngeal-targeted non-invasive ventilation adjustment on health-related quality of life in chronic obstructive pulmonary disease

    by Anne Kristine Brekka, Petrine Veierød Solli, Solfrid Indrekvam, Merete Salveson Engeset, Ola Drange Røksund, Hege Clemm, Sverre Lehmann, John-Helge Heimdal, Thomas Halvorsen, Patrick Brian Murphy, et al.

    Background: Non-invasive ventilation (NIV) in chronic obstructive pulmonary disease (COPD) may induce laryngeal obstruction, causing discomfort, sleep disturbance and reduced treatment adherence. As a major aim of long-term NIV in chronic hypercapnic COPD is to maintain or improve health-related quality of life (HRQoL), minimizing adverse laryngeal responses may be clinically relevant. Aims: To assess changes in overall HRQoL following individualized laryngeal-guided NIV adjustment in patients with COPD. Methods: A longitudinal study was conducted in individuals with stable chronic hypercapnic COPD treated with home NIV. NIV settings were individualized based on laryngeal response assessment to optimize airway patency and comfort. HRQoL was assessed at baseline and at six months using the Severe Respiratory Insufficiency (SRI) questionnaire (0-100 % scale), with higher scores indicating better HRQoL. Arterial carbon dioxide tension (PaCO₂) and home NIV compliance were recorded at both time points. Results: Fifteen individuals with stable COPD were included (6 female). erj;68/suppl_70/PA3229/TB1 T1 TB1 Baseline Change in score p-values SRI Mean 95% CI Sum score 62.87 54.22-71.51 1.8 0.46 Respiratory Complaints 57.92 45.86-69.98 2.71 0.36 Physical Functioning 45.00 32.36-57.64 -3.89 0.29 Attendant Symptoms and Sleep 69.5 59.75-79.30 5.88 0.75 Social Relationships 76.39 63.61-89.17 -1,33 1.0 Anxiety 70.00 56.04-83.96 0 0.31 Psychological Well-Being 70.00 57.00-83.00 3,33 0.74 Social Functioning 55.12 42.35-67.89 -1,49 0.15 PCO2, kPa 5.80 5.33-6.28 -0.23 0.57 Home NIV compliance, min 481.2 411.46-550.94 -10.63 Conclusion: In patients with COPD already established on home NIV, individualized adjustments guided by laryngeal responses over six months preserved overall HRQoL.

  • Open Access

    Can laryngeal ultrasound detect laryngeal movements during mechanically assisted cough?

    by Tiina Maarit Andersen, Anne Kristine Brekka, George Ntoumenopoulos, Aase Johnsen Rogde, Hege Havstad Clemm, Thomas Halvorsen, Ola Drange Røksund, Maria Vollsæter

    Background: Mechanical insufflation–exsufflation (MI-E) is used to augment ineffective cough, but treatment efficacy depends on appropriate upper airway response. Transnasal flexible laryngoscopy (TFL) is the reference standard for assessing laryngeal responses, but is invasive. This study evaluated whether laryngeal ultrasonography (US) can assess laryngeal responses during MI-E. Methods: In this cross-sectional study, healthy volunteers underwent MI-E with both passive and active cough efforts, while TFL and US were performed simultaneously. Laryngeal US was applied using anterior and lateral approaches. Recordings were analysed retrospectively frame-by-frame by two blinded raters. Assessability was defined as appropriate visualisation of the vocal folds or aryepiglottic folds. Visualisation success rates and concordance between laryngeal US and TFL findings were calculated across pre-specified MI-E cycles. Inter-rater reliability for US interpretation was assessed in a subset. Results: 30 adult participants and 875 MI-E cycles were included. At least one laryngeal US approach yielded assessable data in all participants, with lower assessability in males. Across MI-E cycles, visualisation success rates were higher for TFL than for laryngeal US (93.5% versus 68%). Concordance between US and TFL was 78% and 79% during passive and active insufflation, 80% and 88% during passive and active exsufflation, and 92% during active cough compression. Inter-rater reliability was substantial (κ=0.62). Conclusion: This exploratory study suggests that laryngeal US may offer a feasible noninvasive approach to assess laryngeal responses during MI-E, but TFL remains the reference standard. Further validation in patient populations is required.


  • Open Access

    Laryngeal Responses During Non-Invasive Ventilation in Stable Chronic Obstructive Pulmonary Disease: An Observational Study

    by Anne Kristine Brekka, Petrine Solli, Solfrid Indrekvam, Merete Engeset, Ola Røksund, Sverre Lehmann, Hege Clemm, Thomas Halvorsen, John-Helge Heimdal, Patrick Murphy, et al.

    Long-term non-invasive ventilation (NIV) is an established therapy for hypercapnic chronic obstructive pulmonary disease (COPD); however, many patients remain challenging to ventilate effectively. We hypothesized that NIV-induced laryngeal obstruction (NIV-ILO), observed during laryngoscopy, may contribute to reduced ventilatory effectiveness, and that this obstruction can be identified using laryngeal ultrasound (US). This exploratory cross-sectional study included 15 participants with stable COPD receiving long-term NIV. Laryngeal responses were assessed using transnasal flexible laryngoscopy (TFL) and US. Assessments began during spontaneous breathing, followed by NIV at each participant’s prescribed settings. Inspiratory positive airway pressure (IPAP) was increased in 2 cmH2O increments to the device’s maximum. Laryngeal responses were assessed in real time and reassessed retrospectively from video recordings. The participants rated discomfort using a numeric rating scale (0–10). Fifteen participants (40% female) were included. The prescribed IPAP ranged from 7 to 30 cmH2O, with NIV-ILO observed in 5 of 15 participants at a median of 22.0 cmH2O. During subsequent pressure increments, additional 6 of 15 developed NIV-ILO at a median (range) IPAP of 20.5 cmH2O (16.0–30.0), yielding 11 participants (73.3%) developing NIV-ILO within the pressure range of their device. US was assessable in 11 participants, with the structures of interest visualized during 54 of 63 pressure increments. The two methods demonstrated complete concordance for all assessable findings. NIV-ILO was common in patients with COPD using long-term NIV, occurring within the pressure range typically applied to achieve effective ventilation. US can serve as a less invasive diagnostic alternative to TFL.


  • Open Access

    Exploring upper airway and laryngeal resistance to noninvasive ventilation in healthy awake adults

    by Anne Kristine Brekka, Maria Vollsæter, Zoe Fretheim‐Kelly, Manel Lujan, Roy Miodini Nilsen, Hege Havstad Clemm, John‐Helge Heimdal, Thomas Halvorsen, Ove Fondenes, Ola Drange Røksund, et al.

    The interaction between anatomical structures, pressure, and airflow impacts the airway resistance. The airflow during noninvasive ventilation (NIV) relies on the upper airway and laryngeal patency. This study aimed to quantify the airflow resistance at these levels during NIV. In this cross‐sectional study examining 10 healthy, awake adults, we established a NIV setup incorporating a continuous video‐recorded transnasal laryngoscopy and simultaneous airway pressure measurement using a transducer positioned above and below the vocal folds. Airflow and mask pressure were recorded by a pneumotachograph at the mask. NIV was delivered with inspiratory positive pressure (IPAP)/expiratory positive pressure (EPAP) set to 10/4 and 15/4 cmH 2 O. Upper airway (R uaw ) and translaryngeal (R tl ) resistance were calculated and compared with laryngoscopic findings. During IPAP10/EPAP4, the R uaw was 4.25/4.21 and R tl 2.20/3.45. During IPAP15/EPAP4, the R uaw was 5.18/5.73, and the R tl was 2.31/3.83. R uaw was significantly higher than R tl for inspiration at both IPAP levels ( p = 0.001 and p = 0.012), and for expiration with IPAP15/EPAP4 ( p = 0.048). The resistance appeared dynamic during the NIV cycle, and the findings aligned with the laryngoscopic observations. NIV modulates upper airway and translaryngeal resistance. Resistance increases with elevated IPAP levels, particularly within the upper airway.


  • Open Access

    Use of Laryngeal Ultrasound to Observe Laryngeal Movements During Noninvasive Ventilation in Healthy Volunteers

    by Anne Kristine Brekka, George Ntoumenopoulos, Ola Drange Røksund, Merete Salveson Engeset, Hege Clemm, Thomas Halvorsen, Maria Vollsæter, Tiina Andersen

    Background: Transnasal fiberoptic laryngoscopy (TFL) has revealed that laryngeal obstruction can hamper assisted ventilation. TFL may be considered invasive, and laryngeal ultrasound (US) could be a noninvasive alternative. The objective of this study was to investigate the feasibility of using laryngeal US to study laryngeal movements in healthy adult volunteers undergoing noninvasive ventilation (NIV) and to compare the observations with those of simultaneous TFL. Methods: In this cross-sectional study, 30 participants (19 females, age 22–65 y) underwent simultaneous video-recorded TFL and laryngeal US, breathing with and without NIV. Laryngeal US was repeated for anterior and both lateral approaches; the last 5 breaths from each assessment were analyzed. The participants rated discomfort using a numeric rating scale (NRS) from 0 (no discomfort)–10 (worst). Two blinded raters separately described and scored the TFL and laryngeal US recordings, and the findings were subsequently compared. The last 10 laryngeal US recordings were tested for interrater reliability. Results: All participants were successfully assessed using the anterior and both lateral laryngeal US approaches during NIV. Both techniques were well tolerated; 5/30 scored 0 on NRS for TFL and 22/30 for laryngeal US. The visualization rate for all recorded breaths was 99.1% for TFL compared to 81.7% for laryngeal US; overall concordance rate was 84.6%. The discordance rate for the TFL versus laryngeal US observations was 11.1% for vocal fold movements and 11.7% for aryepiglottic fold movements. Interrater reliability showed substantial agreement (0.71). Conclusions: Laryngeal US emerged as a feasible method to describe laryngeal movements during NIV, providing high-quality observations and high concordance with TFL.


  • Laryngeal observations during non-invasive ventilation titration in chronic obstructive pulmonary disease

    by Anne Kristine Brekka, Solfrid Indrekvam, Petrine Veierød Solli, Merete Salveson Engeset, Ola Drange Røksund, Sverre Lehmann, Hege Clemm, Thomas Halvorsen, Patrick Murphy, Maria Vollsæter, et al.

    Background: High-pressure non-invasive ventilation (NIV) is used in chronic obstructive pulmonary disease (COPD) to normalize hypercapnia, thereby enhancing quality of life and improving survival. Despite the benefits, treatment adherence poses challenges. We hypothesized that adverse upper airway responses during NIV may influence treatment efficacy and patient outcomes. Aims: To visualise and describe the laryngeal responses to NIV in individuals with COPD. Methods: An explorative observational study including awake individuals with stable hypercapnic COPD. Laryngeal responses were examined with video-recorded transnasal fiberoptic laryngoscopy during NIV treatment, using a predefined titration protocol starting from each participant’s individual settings up to the inspiratory pressure (IPAP) limit of the patients’ device (25 or 30 cmH2O). The laryngeal responses during NIV were assessed from video-recordings. Results: Eight participants with COPD were included, baseline IPAP levels ranging from 12-26 cmH2O. Among participants where the device’s upper IPAP limit was 25 cmH2O (n=4; baseline IPAP 12-22), 3/4 had normal laryngeal responses. In participants using a device with an upper limit of 30 cmH2O (n=4; baseline IPAP 14-26) laryngeal adduction was observed at high pressures in all. Conclusion: Laryngeal responses to NIV in hypercapnic stable COPD were heterogeneous, with a tendency for increased IPAP to induce laryngeal adduction. Further studies are warranted, using NIV devices capable of delivering higher pressures, to ascertain whether laryngeal obstruction occurs exclusively at pressures exceeding 25 cmH2O.

  • Observed laryngeal responses during non-invasive ventilation in healthy volunteers

    by Anne Kristine Brekka, George Ntoumenopoulos, Ola Drange Røksund, Merete Salveson Engeset, Hege Clemm, Thomas Halvorsen, Maria Vollsæter, Tiina Andersen

    Background: Non-invasive ventilation (NIV) is a vital method for managing respiratory failure. The larynx may resemble a malfunctioning valve and obstruct free airflow. While transnasal fiberoptic laryngoscopy (TFL) effectively observes the laryngeal responses, less invasive techniques would be preferable. Laryngeal point of care ultrasound (L-POCUS) emerges as a potential alternative. Prior to integrating L-POCUS into the assessment of NIV-dependent patients, it is imperative to investigate the feasibility of this method. Aims: To evaluate the viability of L-POCUS for monitoring and characterizing laryngeal responses during NIV, and to compare with those acquired through TFL. Method: In this cross-sectional investigation, thirty healthy participants (19 female) participated in concurrent video-recorded TFL and L-POCUS during NIV treatment (S-mode, IPAP 20, EPAP 4). L-POCUS was performed thrice using anterior, right and left approaches, and the analyses focused on the last five breaths. Two blinded evaluators independently described and scored both TFL and L-POCUS recordings, subsequently comparisons were made between their findings. Interrater-reliability was assessed for the last ten recordings. Results: All participants were successfully assessed using the L-POCUS approaches. The visualization rate was 99.1% for TFL compared to 81.7% for L-POCUS. The overall concordance rate for the laryngeal responses was 84.6%; with 88.9% and 88.3% for movements of vocal folds and aryepiglottic folds, respectively. Interrater reliability showed substantial agreement. Conclusion: L-POCUS proved to be a viable approach for characterizing laryngeal responses during NIV, exhibiting a strong concordance with TFL.


  • Open Access

    Upper Airway and Translaryngeal Resistance During Mechanical Insufflation-Exsufflation

    by Tiina M. Andersen, Anne Kristine Brekka, Zoe Fretheim-Kelly, Manel Lujan, John-Helge Heimdal, Hege H. Clemm, Thomas Halvorsen, Ove Fondenes, Roy M. Nilsen, Ola D. Røksund, et al.


  • Open Access

    Adjustments of non-invasive ventilation and mechanically assisted cough by combining ultrasound imaging of the larynx with transnasal fibre-optic laryngoscopy: a protocol for an experimental study

    by Anne Kristine Brekka, Maria Vollsæter, George Ntoumenopoulos, Hege Havstad Clemm, Thomas Halvorsen, Ola Drange Røksund, Tiina Maarit Andersen

    Introduction Application of non-invasive positive airway pressure may provoke laryngeal responses that obstruct the airways, especially in patients with disturbed laryngeal control. To control and adjust for this, transnasal fibre-optic laryngoscopy (TFL) is used to visualise laryngeal movements during therapeutic interventions. Being an invasive procedure, this may be unpleasant for patients. The aim of this study is to evaluate if ultrasound (US) imaging of the larynx may be used as an alternative less invasive diagnostic tool for evaluating the upper airway responses to non-invasive ventilation (NIV) and mechanical insufflation–exsufflation (MI-E). Methods and analysis This protocol presents an experimental cross-sectional study of a novel method to study laryngeal responses in adult healthy volunteers (n=30). The participants will be assessed with simultaneous TFL and laryngeal US imaging (anterior and lateral approaches) during NIV and MI-E therapy. Additionally, airflow and pressure signals will be registered during the procedures. The primary outcome is whether laryngeal US is a feasible method to study laryngeal responses and, if so, to compare the laryngeal responses visualised with TFL and US. The participants’ perception of the examinations will be recorded. Secondary outcomes include airflow curve shapes and calculated ventilation volumes during the interventions. Ethics and dissemination The study has been approved by The Regional Committee for Medical Research Ethics in Norway, and registered in ClinicalTrials.gov. Results will be disseminated through peer-reviewed journals, presentation of scientific abstracts at international medical conventions and oral presentations in relevant medical conventions. Trial registration number NCT04586855.