Luís Carlos Leal Santana
Luís Carlos Leal Santana has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Joni Augusto Cirelli
Department of Diagnosis and Surgery, School of Dentistry at Araraquara, Sao Paulo State University - UNESP, Araraquara, São Paulo, Brazil
2 shared publications - Luis Geraldo Vaz
Universidade Estadual Paulista, Brazil
2 shared publications - Barbara Araújo dos Reis
Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), School of Dentistry , Araraquara, São Paulo 14801-385, Brazil
1 shared publication - Camila Cristina De Foggi
Department of Conservative Dentistry, Federal University of Rio Grande do Sul (UFRGS), Dental School , Porto Alegre, Rio Grande do Sul 90035-003, Brazil
1 shared publication Camila Cristina de Foggi
Department of Conservative Dentistry, Dental School, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Brazil
1 shared publicationCamila De Foggi
Fed Univ Sao Carlos UFSCar, Chem Dept, Sao Carlos, SP, Brazil
1 shared publication
Latest Publications
- 9 January 2026
- Published by Springer Nature in British Dental Journal
- Vol. 240 (1) , 41
‘Don't look back in anger': the cost of ignoring periodontitis in T2DM
- 9 January 2026
- Published by Springer Nature in British Dental Journal
- Vol. 240 (1) , 41
‘Don't look back in anger': the cost of ignoring periodontitis in T2DM
- 8 August 2025
- Published by Springer Nature in British Dental Journal
- Vol. 239 (3) , 183-184
Which hits harder: place or parents? Unpacking family risk in children's dental extractions
- 8 August 2025
- Published by Springer Nature in British Dental Journal
- Vol. 239 (3) , 183-184
Which hits harder: place or parents? Unpacking family risk in children's dental extractions
- 29 February 2024
- Published by Springer Nature in Journal of Materials Research
- Vol. 39 (8) , 1232-1245
Strontium-loaded titanium surface promotes the MC3T3-E1 pre-osteoblasts growth and S. aureus adhesion
- 29 February 2024
- Published by Springer Nature in Journal of Materials Research
- Vol. 39 (8) , 1232-1245
Strontium-loaded titanium surface promotes the MC3T3-E1 pre-osteoblasts growth and S. aureus adhesion
- 7 June 2023
- Published by Wiley in Oral Diseases
- Vol. 30 (5) , 3504-3505
Artificial Intelligence (AI) and periodontal risk assessment
- 7 June 2023
- Published by Wiley in Oral Diseases
- Vol. 30 (5) , 3504-3505
Artificial Intelligence (AI) and periodontal risk assessment
- 31 May 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (9) , 1-34
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.
- 31 May 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (9) , 1-34
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
Short dental implants with platform matching connection have been used for the rehabilitation of atrophic jaws whenever standard-length dental implants cannot be placed without prior bone augmentation. Yet, there remains a lack of data regarding the risk of technical failures when the all-on-4 configuration is performed in atrophic jaws with platform-switching distal short dental implants. Thus, the current study used the finite element method to evaluate the mechanical behavior at the level of the prosthetic components of the all-on-4 concept performed in atrophic mandible using short-length distal implants with platform switching (PSW) connection. Three models of the all-on-4 configuration were generated in human atrophic mandibles. The geometric models consisted of PSW connection tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) and straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants. A resultant force of 300 N was performed obliquely in the left side and posterior region of the prosthetic bar. The von Mises equivalent stress (σvm) and maximum and minimum principal stresses (σmax and σmin) were performed at level of the prosthetic components/implants and peri-implant bone crest, respectively. The general displacement of the models was also evaluated. The stress analysis was performed on the side of load application. The AO4S configuration showed the lowest values of σvm in the mesial left (ML) and distal left (DL) abutments (37.53 MPa and 232.77 MPa, respectively) and dental implants (91.53 MPa and 231.21 MPa, respectively). The AO4Sh configuration showed the highest values of σvm in the bar screw (102.36 MPa), abutment (117.56 MPa), and dental implant (293.73 MPa) of the ML area. Among the models, the highest values of σmax and σmin were noticed in the peri-implant bone crest of the AO4T design (131.48 MPa and 195.31 MPa, respectively). All models showed similar values of general displacements, which were concentrated in the mandible symphysis. The all-on-4 configurations designed with PSW connection and tilted standard (AO4T; θ = 30 deg; 11 mm-length), straight standard (AO4S; θ = 0 deg; 11 mm-length) or straight short (AO4Sh; θ = 0 deg; 8 mm-length) distal implants were not associated with higher odds of technical failures. The AO4Sh design may be a promising option for the prosthetic rehabilitation of atrophic jaws.
- 3 June 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (4) , 045007
Strontium-loaded titanium-15molybdenum surface improves physicochemical and biological properties in vitro
The titanium alloy composition and microdesign affect the dynamic interplay between the bone cells and titanium surface in the osseointegration process. The current study aimed to evaluate the surface physicochemical properties, electrochemical stability, and the metabolic response of the MC3T3-E1 cells (pre-osteoblast cell line) cultured onto titanium-15molybdenum (Ti-15Mo) discs treated with phosphoric acid (H 3 PO 4 ) and sodium hydroxide (NaOH) and/or strontium-loading by the hydrothermal method. The x-ray dispersive energy spectroscopy (EDS) and x-ray diffraction (XRD) analysis showed no trace of impurities and the possible formation of hydrated strontium oxide (H 2 O 2 Sr), respectively. The confocal laser microscopy (CLSM) analysis indicated that titanium samples treated with strontium (Sr) showed greater surface roughness. The acid/alkali treatment prior to the hydrothermal Sr deposition improved the surface free energy and resistance to corrosion of the Ti-15Mo alloy. The acid/alkali treatment also provided greater retention of the Sr particles on the Ti-15Mo surfaces accordingly with inductively coupled plasma optical emission spectrometry (ICP-OES) analysis. The AlamarBlue and fluorescence analysis indicated noncytotoxic effects against the MC3T3-E1 cells, which allowed cells’ adhesion and proliferation, with greater cells’ spreading in the Sr-loaded Ti-15Mo samples. These findings suggest that Sr deposition by the hydrothermal method has the potential to enhance the physicochemical properties of the Ti-15Mo previously etched with H 3 PO 4 and NaOH, and also improve the initial events related to cell-mediated bone deposition.
- 3 June 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (4) , 045007
Strontium-loaded titanium-15molybdenum surface improves physicochemical and biological properties in vitro
The titanium alloy composition and microdesign affect the dynamic interplay between the bone cells and titanium surface in the osseointegration process. The current study aimed to evaluate the surface physicochemical properties, electrochemical stability, and the metabolic response of the MC3T3-E1 cells (pre-osteoblast cell line) cultured onto titanium-15molybdenum (Ti-15Mo) discs treated with phosphoric acid (H 3 PO 4 ) and sodium hydroxide (NaOH) and/or strontium-loading by the hydrothermal method. The x-ray dispersive energy spectroscopy (EDS) and x-ray diffraction (XRD) analysis showed no trace of impurities and the possible formation of hydrated strontium oxide (H 2 O 2 Sr), respectively. The confocal laser microscopy (CLSM) analysis indicated that titanium samples treated with strontium (Sr) showed greater surface roughness. The acid/alkali treatment prior to the hydrothermal Sr deposition improved the surface free energy and resistance to corrosion of the Ti-15Mo alloy. The acid/alkali treatment also provided greater retention of the Sr particles on the Ti-15Mo surfaces accordingly with inductively coupled plasma optical emission spectrometry (ICP-OES) analysis. The AlamarBlue and fluorescence analysis indicated noncytotoxic effects against the MC3T3-E1 cells, which allowed cells’ adhesion and proliferation, with greater cells’ spreading in the Sr-loaded Ti-15Mo samples. These findings suggest that Sr deposition by the hydrothermal method has the potential to enhance the physicochemical properties of the Ti-15Mo previously etched with H 3 PO 4 and NaOH, and also improve the initial events related to cell-mediated bone deposition.
- 1 January 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (1) , 75-85
Mechanical Stress Analysis of Different Configurations of the All-on-4 Concept in Atrophic Mandible: A 3D Finite Element Study
Purpose: This study evaluated the mechanical behavior of different configurations of the All-on-4 treatment concept designed with straight short (6-mm-length), straight standard (11-mm-length), or tilted standard (30-degree angled; 11-mm-length) posterior implants. Materials and Methods: The All-on-4 configurations were performed in atrophic mandible models and consisted of anterior straight standard and posterior tilted standard implants (H1 model), anterior straight standard and posterior straight short implants (H2 model), and anterior and posterior straight standard implants (H3 model). Three oblique forces of 100 N were simulated in the posterior region of the prosthetic bar. The values of stress were obtained for the ductile materials using the von Mises equivalent stress (sigma(vm)) criteria. The stress peaks in the peri-implant bone crest were measured by the maximum (sigma(max)) and minimum (sigma(min)) principal stresses. The two-way analysis of variance (two-way ANOVA) and Tukey post hoc tests determined significant differences (P < .01) of stress values among the ductile materials (implant and prosthetic components). Results: The use of tilted standard posterior implants (H1 model) showed the lowest values of sigma(max) and sigma(min) in the posterior region of the peri-implant bone area. On the other hand, the use of straight short (H2 model) or straight standard (H3 model) posterior implants significantly reduced the von Mises mean stresses in the bar screws, abutments, and abutment screws (P < .01). Conclusion: The higher odds of technical failures (screw fracture/loosening) may be expected when the All-on-4 configuration is performed with tilted standard posterior implants. Also, peri-implant bone overload may occur when the All-on-4 design is performed with straight short or straight standard posterior implants in atrophic mandibles.
- 1 January 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (1) , 75-85
Mechanical Stress Analysis of Different Configurations of the All-on-4 Concept in Atrophic Mandible: A 3D Finite Element Study
Purpose: This study evaluated the mechanical behavior of different configurations of the All-on-4 treatment concept designed with straight short (6-mm-length), straight standard (11-mm-length), or tilted standard (30-degree angled; 11-mm-length) posterior implants. Materials and Methods: The All-on-4 configurations were performed in atrophic mandible models and consisted of anterior straight standard and posterior tilted standard implants (H1 model), anterior straight standard and posterior straight short implants (H2 model), and anterior and posterior straight standard implants (H3 model). Three oblique forces of 100 N were simulated in the posterior region of the prosthetic bar. The values of stress were obtained for the ductile materials using the von Mises equivalent stress (sigma(vm)) criteria. The stress peaks in the peri-implant bone crest were measured by the maximum (sigma(max)) and minimum (sigma(min)) principal stresses. The two-way analysis of variance (two-way ANOVA) and Tukey post hoc tests determined significant differences (P < .01) of stress values among the ductile materials (implant and prosthetic components). Results: The use of tilted standard posterior implants (H1 model) showed the lowest values of sigma(max) and sigma(min) in the posterior region of the peri-implant bone area. On the other hand, the use of straight short (H2 model) or straight standard (H3 model) posterior implants significantly reduced the von Mises mean stresses in the bar screws, abutments, and abutment screws (P < .01). Conclusion: The higher odds of technical failures (screw fracture/loosening) may be expected when the All-on-4 configuration is performed with tilted standard posterior implants. Also, peri-implant bone overload may occur when the All-on-4 design is performed with straight short or straight standard posterior implants in atrophic mandibles.