Pranee Rattanawaleedirojn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pranee Rattanawaleedirojn has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Nadnudda Rodthongkum
Center of Excellence in Responsive Wearable Materials, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330, Thailand
2 shared publications Chatchai Buekban
National Electronics and Computer Technology Center (NECTEC), Pathumthani, 12120, Thailand
1 shared publication- Chusak Thanawattano
Biomedical Electronics and Systems Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center (NECTEC), Pathum Thani 12120, Thailand
1 shared publication Nadtinan Promphet
Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok, 10330, Thailand
1 shared publication- Nattachai Srisawat
Excellence Center for Critical Care Nephrology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand
1 shared publication Orawon Chailapakul
Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand
1 shared publication
Latest Publications
- 21 May 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1312, 342761
Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening
- 21 May 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1312, 342761
Smartphone based wearable sweat glucose sensing device correlated with machine learning for real-time diabetes screening
- 26 May 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (12) , 2819-2827
A portable blood lactate sensor with a non-immobilized enzyme for early sepsis diagnosis
Early determination of blood lactate levels may accelerate the detection of sepsis, one of the most time-sensitive illnesses. We developed and validated a portable blood lactate detection kit for clinical screening that can measure early bedside lactate levels in intensive care unit (ICU) patients suspected of having sepsis. A TiO2 sol–G nanocomposite was prepared and coated on a screen-printed carbon electrode (SPCE) integrated with non-immobilized lactate oxidase (LOx) to produce a novel lactate biosensor with high sensitivity and high storage stability for human blood lactate measurement. The detection kit was based on an electrochemical technique and showed a wide linear range of 1–20 mM (R2 = 0.9937) with a low detection limit of 0.2 mM for lactate detection. This allowed for differentiating patient groups who may have sepsis using a cut-off level of 4 mM. The device was successfully implemented for blood lactate determination in critical patients, showing an accuracy range from 75% to 112%. This device provided high-precision and rapid quantitative information validated using a blood gas analyzer. Our detection kit might help to reduce the morbidity and mortality rates in severe sepsis and septic shock patients in community hospitals.
- 26 May 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (12) , 2819-2827
A portable blood lactate sensor with a non-immobilized enzyme for early sepsis diagnosis
Early determination of blood lactate levels may accelerate the detection of sepsis, one of the most time-sensitive illnesses. We developed and validated a portable blood lactate detection kit for clinical screening that can measure early bedside lactate levels in intensive care unit (ICU) patients suspected of having sepsis. A TiO2 sol–G nanocomposite was prepared and coated on a screen-printed carbon electrode (SPCE) integrated with non-immobilized lactate oxidase (LOx) to produce a novel lactate biosensor with high sensitivity and high storage stability for human blood lactate measurement. The detection kit was based on an electrochemical technique and showed a wide linear range of 1–20 mM (R2 = 0.9937) with a low detection limit of 0.2 mM for lactate detection. This allowed for differentiating patient groups who may have sepsis using a cut-off level of 4 mM. The device was successfully implemented for blood lactate determination in critical patients, showing an accuracy range from 75% to 112%. This device provided high-precision and rapid quantitative information validated using a blood gas analyzer. Our detection kit might help to reduce the morbidity and mortality rates in severe sepsis and septic shock patients in community hospitals.