ZZZhilong Zheng

Zhilong Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhilong Zheng has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modeling and Prediction of Water-Jet-Guided Laser Cutting Depth for Inconel 718 Material Using Response Surface Methodology

    by Chuang Zhao, Yugang Zhao, Dandan Zhao, Qian Liu, Jianbing Meng, Chen Cao, Zhilong Zheng, Zhihao Li, Hanlin Yu

    In this study, the water-jet-guided laser (WJGL) method was used to cut Inconel 718 alloy with high temperature resistance. The effect of critical parameters of the water-jet-guided laser machining method on the cutting depth was studied by a Taguchi orthogonal experiment. Furthermore, the mathematical prediction model of cutting depth was established by the response surface method (RSM). The validation experiments showed that the mathematical model had a high predictive ability for cutting depth. The optimal cutting depth was obtained by model prediction, and the error was 5.5% compared with the experimental results. Compared with the traditional dry laser cutting, the water conducting laser method reduced the thermal damage and improved the cutting quality. This study provides a reference for the precision machining of Inconel 718 with a water-jet-guided laser.


  • Open Access

    Experimental Research and Optimization of Ti-6Al-4V Alloy Microgroove Machining Based on Waterjet-Guided High-Power Laser

    by Qian Liu, Yugang Zhao, Jianbing Meng, Zhilong Zheng, Chen Cao, Guoyong Zhao, Chuang Zhao, Guangxin Liu, Di Dai, Zhuang Song

    In order to improve the tribological properties of Ti-6Al-4V alloy and further broaden the application scope of titanium alloy materials in the industrial field, a preparation method of a waterjet-guided high-power laser processing surface microgroove was studied. In this paper, a multifocus coupling lens was innovatively designed to replace the spherical lens in the traditional waterjet-guided laser coupling device, which avoids the gas explosion phenomenon in the coupling of the high-power laser and waterjet, and realizes the high-quality coupling of the high-power laser and water beam fiber. Then, with the microgroove morphology as the response target, the single-factor test and response surface test of the water-guided laser processing microgroove were carried out. Based on the experimental results, an approximate mathematical model of the response surface between the process parameters and the microgroove topography target was constructed, and the quantitative relationship between the waterjet-guided laser processing parameters and the target response was studied. At the same time, the optimal combination of process parameters was obtained by multiobjective optimization, so as to effectively improve the microgroove morphology. This technology provides method guidance and a decision-making reference for subsequent waterjet-guided laser processing of titanium alloy surface functional microstructures.


  • Open Access

    Fabrication of Ultra-Fine and Ultra-Long Copper Tube Electrodes by Ultrasonic High-Frequency Percussion

    by Xiajunyu Zhang, Yugang Zhao, Hanlin Yu, Zhihao Li, Chuang Zhao, Guangxin Liu, Chen Cao, Qian Liu, Zhilong Zheng, Dandan Zhao

    In this study, a new method of ultrasonic high-frequency percussion (UH-FP) is proposed. Ultra-fine and ultra-long copper tube electrodes cannot be fabricated by traditional processing methods, and the copper tube electrodes fabricated by UH-FP can be used in the process of rotary EDM for microfine holes. The UH-FP setup has been established based on an ultrasonic device, a workpiece chucking and rotation device, and a workpiece reciprocating motion device. In this work, by studying the principle of ultrasonic processing, the processing principle and mechanism of ultra-fine and ultra-long copper tube electrode preparation by ultrasonic high-frequency percussion is proposed. The effects of processing parameters (i.e., rotational speed, feed rate, working gap, percussion amplitude) on surface roughness are evaluated quantitatively. Experimental results show that the proposed method could complete the core leach of the core-containing copper tube electrodes after drawing, while improving surface quality. Some surface defects such as cracks, scratches and folds were completed removed, further improving the mechanical performance of processed parts. The surface roughness (Ra) of 0.091 μm was obtained from the initial 0.46 μm under the optimal processing parameters of 800 rpm tube rotational speed, 200 mm/min platform feed speed, 0.13 mm machining gap, 0.15 mm percussion amplitude, and 32 min machining time. The method shows potential for manufacturing copper tube electrodes for a wide range of industrial applications.

  • Open Access

    Study on the Micro Removal Process of Inner Surface of Cobalt Chromium Alloy Cardiovascular Stent Tubes

    by Zhuang Song, Yugang Zhao, Zhihao Li, Chen Cao, Guangxin Liu, Qian Liu, Xiajunyu Zhang, Di Dai, Zhilong Zheng, Chuang Zhao, et al.

    Due to the special manufacturing process of cobalt–chromium alloy cardiovascular stent tubes, there are serious surface defects in their inner walls, which affects the therapeutic effect after implantation. At the same time, the traditional processing technology cannot finish the inner wall of a cardiovascular stent tube. In light of the above problems, magnetic abrasive finishing (MAF) equipment for the inner wall of an ultra-fine and ultra-long cardiovascular stent tube is proposed, and MAF technology is used to improve the surface quality of its inner wall. High-performance spherical magnetic abrasive powders are used to finish the inner wall of a cobalt–chromium alloy cardiovascular stent tube with an inner diameter of 1.6 mm and an outer diameter of 1.8 mm. The effects of finishing time, tube rotational speed, feed speed of the magnetic pole, MAPs filling quantity, and MAP abrasive size on the surface roughness and material removal thickness of cobalt–chromium alloy cardiovascular stent tube are investigated. The results show that the surface roughness of the inner wall of the cobalt–chromium alloy cardiovascular stent decreases from 0.485 μm to 0.101 μm, and the material removal thickness of the defect layer is 4.3 μm. MAF technology is used to solve the problem of the poor surface quality of the inner walls of ultra-fine and ultra-long cobalt–chromium alloy cardiovascular stent tubes.


  • Open Access

    Experimental Investigation on Process Parameters during Laser-Assisted Turning of SiC Ceramics Based on Orthogonal Method and Response Surface Methodology

    by Di Dai, Yugang Zhao, Chen Cao, Ruichun Dong, Haiyun Zhang, Qian Liu, Zhuang Song, Xiajunyu Zhang, Zhilong Zheng, Chuang Zhao

    In this study, laser-assisted machining experiments are carried out on silicon carbide (SiC) ceramic materials by a turning process, and laser power, cutting depth, rotational speed, and feed speed are selected as research factors. In order to improve the surface processing quality of laser-assisted turning of SiC ceramics and obtain the smallest surface roughness, the orthogonal method and response surface method are used to investigate the effect of various factors on surface roughness. The effect of various factors on surface roughness is evaluated by variance analysis, mean analysis, main effect diagram, 3D response surface, and corresponding contour diagram. The surface roughness prediction model is established based on the response surface method, and the prediction error is 4.1% with high accuracy. The experimental results show that laser power and cutting depth are the most significant factors affecting surface roughness, and rotational speed is a significant factor affecting surface roughness. Under the optimum process conditions, the smallest surface roughness Ra obtained by the response surface method is 0.294 μm, which is lower than 0.315 μm obtained by the orthogonal method, and the surface quality is higher. Therefore, the optimal process parameters of the response surface method can obtain the smallest surface roughness and higher surface quality in laser-assisted turning of SiC ceramics.


  • Open Access

    Research on the Removal Mechanism of Resin-Based Coatings by Water Jet-Guided Quasi-Continuous Laser Cleaning

    by Qian Liu, Yugang Zhao, Jianbing Meng, Ke Wang, Guoyong Zhao, Li Li, Zhilong Zheng, Guangxin Liu, Chen Cao, Di Dai

    Laser cleaning technology has the advantages of being green and efficient and is expected to become the most promising remanufacturing cleaning technology. However, the quasi-continuous laser can easily cause problems, such as a heat-affected zone and a recast layer on the substrate material, which limits the development of laser cleaning technology. The environmentally friendly water jet-guided quasi-continuous laser proposed in this paper is an innovative laser cleaning technology that can remove the resin-based coating on the metal substrate with high quality. The epoxy resin coating on the 304 stainless steel surface was cleaned by a water jet guided quasi continuous laser, and the surface morphology, surface element content, and surface roughness of the cleaning area were tested and analyzed. The removal mechanism of water jet-guided quasi-continuous laser cleaning technology was revealed, and the influence of process parameters on cleaning surface quality was found. The optimal process parameters were as follows: the energy density of the water jet-guided laser 17.5 J/cm2, the cleaning speed 135 mm/s, the cleaning line spacing 0.1 mm, and the laser pulse frequency 900 Hz. Therefore, this study is expected to be an important basis for water jet-guided quasi-continuous laser cleaning technology, and promote the development of water jet-guided laser cleaning technology.