Balaji Baskar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Balaji Baskar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo Aguilar
J. Mike Walker '66 Department of Mechanical Engineering Texas A&M University College Station TX 77840 USA
3 shared publications - Atiqul Islam Ahad
J. Mike Walker '66 Department of Mechanical Engineering Texas A&M University College Station TX 77840 USA
2 shared publications - Carla Berrospe‐Rodriguez
J. Mike Walker '66 Department of Mechanical Engineering Texas A&M University College Station TX 77840 USA
2 shared publications - Aravind Jakkinapalli
Mechanical Engineering, Texas A&M University, College Station, TX 77843, United States of America
1 shared publication C. Berrospe-Rodriguez
1 shared publication- J. Williams1 shared publication
Latest Publications
- 25 August 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Femtosecond Single‐ and Double‐Pulse Fabrication of Periodic Nanostructures on Stainless Steel for Surface‐Enhanced Raman Spectroscopy
- 25 August 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Femtosecond Single‐ and Double‐Pulse Fabrication of Periodic Nanostructures on Stainless Steel for Surface‐Enhanced Raman Spectroscopy
- Open Access
- 29 May 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Femtosecond Single‐ and Double‐Pulse Fabrication of Periodic Nanostructures on Stainless Steel for Surface‐Enhanced Raman Spectroscopy
Fabrication of laser‐induced periodic surface structures (LIPSS) with near‐submicron length scale can greatly modify the surface‐related properties of materials as shown over the past decade. The hydrophobic properties can be combined with the dense nanostructures present in LIPSS to act as hotspots for highly sensitive surface‐enhanced Raman spectroscopy (SERS) applications. In this study, usage of single and double fs laser pulse irradiation to obtain different morphologies of LIPSS is demonstrated. By controlling the polarization, fluency, and interpulse delay between fs pulses, 1D and 2D periodic nanostructures are generated on 304‐stainless‐steel substrates, and the corresponding formation mechanisms are discussed. The LIPSS‐based sensors exhibit a high contact angle of 112°, demonstrating good capability of depositing analyte molecules after evaporation for SERS detection. Furthermore, the dense hotspots present in LIPSS‐based SERS sensors can detect up to 10−10 M concentration of Rhodamine 6G with an analytical enhancement factor of 2 × 107. The substrates also demonstrated uniform and repeatable measurements with an RSD of 9.64%. The results provide insight into controlling laser‐induced submicron morphology by changing experimental parameters as a simple and cost‐effective approach for ultra‐trace detection of molecules.
- 29 May 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Open AccessFemtosecond Single‐ and Double‐Pulse Fabrication of Periodic Nanostructures on Stainless Steel for Surface‐Enhanced Raman Spectroscopy
Fabrication of laser‐induced periodic surface structures (LIPSS) with near‐submicron length scale can greatly modify the surface‐related properties of materials as shown over the past decade. The hydrophobic properties can be combined with the dense nanostructures present in LIPSS to act as hotspots for highly sensitive surface‐enhanced Raman spectroscopy (SERS) applications. In this study, usage of single and double fs laser pulse irradiation to obtain different morphologies of LIPSS is demonstrated. By controlling the polarization, fluency, and interpulse delay between fs pulses, 1D and 2D periodic nanostructures are generated on 304‐stainless‐steel substrates, and the corresponding formation mechanisms are discussed. The LIPSS‐based sensors exhibit a high contact angle of 112°, demonstrating good capability of depositing analyte molecules after evaporation for SERS detection. Furthermore, the dense hotspots present in LIPSS‐based SERS sensors can detect up to 10−10 M concentration of Rhodamine 6G with an analytical enhancement factor of 2 × 107. The substrates also demonstrated uniform and repeatable measurements with an RSD of 9.64%. The results provide insight into controlling laser‐induced submicron morphology by changing experimental parameters as a simple and cost‐effective approach for ultra‐trace detection of molecules.
- 23 July 2024
- Published by Elsevier in Applied Surface Science
- Vol. 672
Wettability tuning on stainless steel LIPSS by laser oxidation and its implication on cavitation bubble dynamics
- 23 July 2024
- Published by Elsevier in Applied Surface Science
- Vol. 672
Wettability tuning on stainless steel LIPSS by laser oxidation and its implication on cavitation bubble dynamics
- Open Access
- 26 May 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (16) , 4891-4899
Femtosecond 3D photolithography through a digital micromirror device and a microlens array
Based on the microscale 3D point cloud projection with a digital micromirror device (DMD) and a microlens array (MLA) developed recently, we explore the capabilities of this specific type of 3D projection in 3D lithography with femtosecond light in this study. Unlike 3D point cloud projection with UV continuous light demonstrated before, high accuracy positioning between the DMD and the MLA is required to have rays simultaneously arrive at the designed voxel positions to induce two-photon absorption with femtosecond light. Because of this additional requirement, a new positioning method through direct microscope inspection of the relative positions of the DMD and the MLA is developed in this study. Because of the usage of a rectangular MLA, around four rays can arrive at each projecting voxel at the same time. Thus, to the best of our knowledge, a new algorithm for determining the pixel map on the DMD to the 3D point cloud projection with a femtosecond laser is also developed. It is observed that a very long exposure time is required to generate 3D patterns with the new 3D projection scheme because of the very limited number of rays used for projecting each voxel with the new algorithm. It is also found that 3D structures with desired shapes should be projected far away from the MLA ( ∼ 15 f to 30 f , with f being the focal distance of the MLA) in the 3D lithography with this femtosecond 3D point cloud projection. For patterns projected closer than 10 f , shapes are distorted because of unwanted voxels cured with the 3D projection technique using a DMD and MLA.
- 26 May 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (16) , 4891-4899
Open AccessFemtosecond 3D photolithography through a digital micromirror device and a microlens array
Based on the microscale 3D point cloud projection with a digital micromirror device (DMD) and a microlens array (MLA) developed recently, we explore the capabilities of this specific type of 3D projection in 3D lithography with femtosecond light in this study. Unlike 3D point cloud projection with UV continuous light demonstrated before, high accuracy positioning between the DMD and the MLA is required to have rays simultaneously arrive at the designed voxel positions to induce two-photon absorption with femtosecond light. Because of this additional requirement, a new positioning method through direct microscope inspection of the relative positions of the DMD and the MLA is developed in this study. Because of the usage of a rectangular MLA, around four rays can arrive at each projecting voxel at the same time. Thus, to the best of our knowledge, a new algorithm for determining the pixel map on the DMD to the 3D point cloud projection with a femtosecond laser is also developed. It is observed that a very long exposure time is required to generate 3D patterns with the new 3D projection scheme because of the very limited number of rays used for projecting each voxel with the new algorithm. It is also found that 3D structures with desired shapes should be projected far away from the MLA ( ∼ 15 f to 30 f , with f being the focal distance of the MLA) in the 3D lithography with this femtosecond 3D point cloud projection. For patterns projected closer than 10 f , shapes are distorted because of unwanted voxels cured with the 3D projection technique using a DMD and MLA.