Irina G. Smirnova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Irina G. Smirnova has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Svetlana A. Vostrikova
ITMO University
3 shared publications - Daniil S. Shiryaev
ITMO University
2 shared publications - Kira O. Pogorelova
Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, Moscow, 107031, Russian Federation, sc 57191545581
2 shared publications - Yurii S. Andreev
Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology, Moscow, 107031, Russian Federation, sc 57191545581
2 shared publications - A. A. Denisova
Admiral Makarov State University of Maritime and Inland Shipping
1 shared publication - Aleksandr Rybalka
Institute of Advanced Data Transfer Systems, ITMO University, Kronverkskiy Pr., 49, Bldg. A, 197198 Saint Petersburg, Russia
1 shared publication
Latest Publications
- 1 January 2026
- Published by ITMO University in Reviews on Advanced Materials and Technologies
- Vol. 8 (2)
Effects of High-Temperature Annealing on the Microstructure and Mechanical Properties of β-Ga2O3:Fe Crystals
In this work, the microstructure and mechanical properties of bulk β Ga2O3:Fe (0.01 mol.%) crystals were investigated using X ray diffraction, optical transmission spectroscopy, and the ultrasonic composite oscillator technique at successive stages of two step annealing at 1400 °C in air. Rocking curves revealed a substantial microstructural evolution, with a more complex profile envelope after 6 hours of annealing and a significant narrowing accompanied by increased reflection intensity after 12 hours. Optical transmission spectra showed an increase in transmittance below 650 nm and a decrease in the long wavelength region. The amplitude dependences of internal friction and the effective elastic modulus were obtained and characterized. Changes in the microplastic yield point under oscillatory deformation and in the background values of these quantities were observed, indicating a reduction in the concentration of mobile defects and microstructural ordering. The effective elastic modulus measured in β Ga2O3:Fe (0.01 mol.%) crystal after annealing along the [100] direction was found to be 339.8 GPa.
- 1 January 2026
- Published by ITMO University in Reviews on Advanced Materials and Technologies
- Vol. 8 (2)
Effects of High-Temperature Annealing on the Microstructure and Mechanical Properties of β-Ga2O3:Fe Crystals
In this work, the microstructure and mechanical properties of bulk β Ga2O3:Fe (0.01 mol.%) crystals were investigated using X ray diffraction, optical transmission spectroscopy, and the ultrasonic composite oscillator technique at successive stages of two step annealing at 1400 °C in air. Rocking curves revealed a substantial microstructural evolution, with a more complex profile envelope after 6 hours of annealing and a significant narrowing accompanied by increased reflection intensity after 12 hours. Optical transmission spectra showed an increase in transmittance below 650 nm and a decrease in the long wavelength region. The amplitude dependences of internal friction and the effective elastic modulus were obtained and characterized. Changes in the microplastic yield point under oscillatory deformation and in the background values of these quantities were observed, indicating a reduction in the concentration of mobile defects and microstructural ordering. The effective elastic modulus measured in β Ga2O3:Fe (0.01 mol.%) crystal after annealing along the [100] direction was found to be 339.8 GPa.
- 30 December 2025
- Published by ITMO University in Reviews on Advanced Materials and Technologies
- Vol. 7 (4)
Electrospun Nanofibers-Based Moist-Electric Generators
Moisture-electric generators provide an innovative and sustainable method for harvesting electricity directly from ambient atmospheric humidity through hygroscopic interactions and ion transport processes. Among diverse architectures, those based on electrospun nanofibers are particularly promising due to their high surface area, superior breathability, mechanical flexibility, and seamless integration into wearable systems. This review provides a comprehensive summary of recent advances in electrospun nanofiber moisture-electric generators, with a focus on fabrication techniques via electrospinning, material optimization through functional additives, device performance metrics, and emerging applications in self-powered wearable electronics, sensors, and smart textiles. Significant improvements in power output and durability have been reported in hybrid designs. Nonetheless, challenges in long-term reliability, manufacturing scalability, and conversion efficiency hinder widespread adoption. Future directions include multifunctional materials, asymmetric device designs, and scalable production strategies to enable practical, battery-free power sources for next-generation wearable technologies.
- 30 December 2025
- Published by ITMO University in Reviews on Advanced Materials and Technologies
- Vol. 7 (4)
Electrospun Nanofibers-Based Moist-Electric Generators
Moisture-electric generators provide an innovative and sustainable method for harvesting electricity directly from ambient atmospheric humidity through hygroscopic interactions and ion transport processes. Among diverse architectures, those based on electrospun nanofibers are particularly promising due to their high surface area, superior breathability, mechanical flexibility, and seamless integration into wearable systems. This review provides a comprehensive summary of recent advances in electrospun nanofiber moisture-electric generators, with a focus on fabrication techniques via electrospinning, material optimization through functional additives, device performance metrics, and emerging applications in self-powered wearable electronics, sensors, and smart textiles. Significant improvements in power output and durability have been reported in hybrid designs. Nonetheless, challenges in long-term reliability, manufacturing scalability, and conversion efficiency hinder widespread adoption. Future directions include multifunctional materials, asymmetric device designs, and scalable production strategies to enable practical, battery-free power sources for next-generation wearable technologies.
- Open Access
- 24 July 2023
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Messenger of ANESTHESIOLOGY AND RESUSCITATION
- Vol. 20 (4) , 19-26-26
Possibilities and prospects for assessing pain nociception in patients with chronic disorders of consciousness
The objective was to study the possibilities of assessing pain nociception in patients with chronic disorders of consciousness (CDC) using the ANI index and to identify differences depending on the level of CDC, to create systems for objectification of pain sensations of patients with CDC. Materials and methods. The study included 29 patients with CDC. Group 1 (9 patients) – vegetative state / unresponsive wakefulness syndrome (VS/UWS), group 2 (20 patients) – minimally conscious state (MCS) – “plus”. The pain stimulus (PS) consisted in pressing on the nail phalanx of the hand with a reflex hammer. The ANI index was recorded three times: at rest (ANI 1), during the application of PS (ANI 2), 30 minutes after the application of PS (ANI 3). The assessment on the pain scale (NCS-R) was performed once during the application of PS. Statistical processing was carried out using the R programming language, a package of applied statistical programs SPSS STATISTICS.Results. The average values of the index difference ANI 2 and ANI 1 in group 1 differed, ANI 2 – ANI 3 had no differences. The average values of the ANI 3 index in groups 1 and 2 differed statistically significantly. A rank correlation between the ANI index and the NCS-R score existed in group 1 in the period after the application of BS. A statistically significant negative correlation was found in group 1 during the application of BS. When comparing the ANI index and the difference between the CRS-R index at discharge and admission, it was found that in group 2, the greater the difference between the CRS-R index at discharge and admission, the lower the value of the ANI index at all stages of the study, and in group 1 the opposite relationship was obtained. In group 1, there was a statistical relationship between the Kerdo index (IR) and the difference between the indices ANI 2 and ANI 1, ANI 2 and ANI 1 and IR, for group 2, the relationship could not be established.Conclusion. The data obtained during the study indicate that there are certain differences in the response to PS in patients in the VS / UWS and MCS ≪plus≫. Сreation of systems for objectification of pain sensations of patients in the VS / UWS will contribute to improving their quality of life.
- 24 July 2023
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Messenger of ANESTHESIOLOGY AND RESUSCITATION
- Vol. 20 (4) , 19-26-26
Open AccessPossibilities and prospects for assessing pain nociception in patients with chronic disorders of consciousness
The objective was to study the possibilities of assessing pain nociception in patients with chronic disorders of consciousness (CDC) using the ANI index and to identify differences depending on the level of CDC, to create systems for objectification of pain sensations of patients with CDC. Materials and methods. The study included 29 patients with CDC. Group 1 (9 patients) – vegetative state / unresponsive wakefulness syndrome (VS/UWS), group 2 (20 patients) – minimally conscious state (MCS) – “plus”. The pain stimulus (PS) consisted in pressing on the nail phalanx of the hand with a reflex hammer. The ANI index was recorded three times: at rest (ANI 1), during the application of PS (ANI 2), 30 minutes after the application of PS (ANI 3). The assessment on the pain scale (NCS-R) was performed once during the application of PS. Statistical processing was carried out using the R programming language, a package of applied statistical programs SPSS STATISTICS.Results. The average values of the index difference ANI 2 and ANI 1 in group 1 differed, ANI 2 – ANI 3 had no differences. The average values of the ANI 3 index in groups 1 and 2 differed statistically significantly. A rank correlation between the ANI index and the NCS-R score existed in group 1 in the period after the application of BS. A statistically significant negative correlation was found in group 1 during the application of BS. When comparing the ANI index and the difference between the CRS-R index at discharge and admission, it was found that in group 2, the greater the difference between the CRS-R index at discharge and admission, the lower the value of the ANI index at all stages of the study, and in group 1 the opposite relationship was obtained. In group 1, there was a statistical relationship between the Kerdo index (IR) and the difference between the indices ANI 2 and ANI 1, ANI 2 and ANI 1 and IR, for group 2, the relationship could not be established.Conclusion. The data obtained during the study indicate that there are certain differences in the response to PS in patients in the VS / UWS and MCS ≪plus≫. Сreation of systems for objectification of pain sensations of patients in the VS / UWS will contribute to improving their quality of life.
- Open Access
- 1 October 2022
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 22 (5) , 951
Visual display system of changes in physiological states for patients with chronic disorders and data transmission via optical wireless communication
A visual display system of changes in the physiological state of patients and their data transmission via optical wireless communication is presented. Existing methods such as bedside monitors do not provide the possibility of visual display of information near the object in conditions of high workload of personnel and allow transmitting data via an electric cable or remotely in the radio frequency range. Such disadvantages reduce the responsiveness of personnel and lead to numerous errors in the transmitted data. A remote operational monitoring system is more effective, providing data collection from sensors, display with minimal delay time and data transmission over an interference-free communication channel in the optical range. A simple and visual way of displaying information allows to quickly and accurately recognize critical situations. The proposed system has two channels. The first channel provides a visual representation of changes in the physiological state on the visual display device in the form of a bracelet. The second channel allows transmitting data about the deviation in the patient’s condition via optical wireless communication in the infrared range of the spectrum for detailed display on a computer. The visual representation of changes in the physiological state is based on programmable change in the color of the LED indicators and on change in their operation modes. The block diagram and design of the visual display and data transmission system are presented. As part of the evaluation of the system operability, the heating of the visual display device in the COMSOL Multiphysics was evaluated. It is shown, that the average heating temperature of the indicator part in contact with human skin does not exceed 24 °C and is safe for the patient. The optical scheme of the receiving unit and the transmitting module is presented. The optical model of the module is presented in the Zemax program. It is shown, that the required average optical power of the working spectral region is 235 μW for the four infrared LEDs and four photodiodes located at a distance of 1 meter. A description of the working layout of a visual display and data transmission device is presented, including a digital pulse sensor and blood oxygen level, a color control and data processing unit, a visual display device, and a data transmission unit. The LEDs operation modes and its compliance with the deviation of the controlled parameters were checked by a special microcontroller program of practical significance. The implementation of the developed system is relevant when monitoring the condition of the object of observation in cases where the use of the radio frequency range is limited and the stability of the data transmission channel to electromagnetic interference plays an important role.
- 1 October 2022
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 22 (5) , 951
Open AccessVisual display system of changes in physiological states for patients with chronic disorders and data transmission via optical wireless communication
A visual display system of changes in the physiological state of patients and their data transmission via optical wireless communication is presented. Existing methods such as bedside monitors do not provide the possibility of visual display of information near the object in conditions of high workload of personnel and allow transmitting data via an electric cable or remotely in the radio frequency range. Such disadvantages reduce the responsiveness of personnel and lead to numerous errors in the transmitted data. A remote operational monitoring system is more effective, providing data collection from sensors, display with minimal delay time and data transmission over an interference-free communication channel in the optical range. A simple and visual way of displaying information allows to quickly and accurately recognize critical situations. The proposed system has two channels. The first channel provides a visual representation of changes in the physiological state on the visual display device in the form of a bracelet. The second channel allows transmitting data about the deviation in the patient’s condition via optical wireless communication in the infrared range of the spectrum for detailed display on a computer. The visual representation of changes in the physiological state is based on programmable change in the color of the LED indicators and on change in their operation modes. The block diagram and design of the visual display and data transmission system are presented. As part of the evaluation of the system operability, the heating of the visual display device in the COMSOL Multiphysics was evaluated. It is shown, that the average heating temperature of the indicator part in contact with human skin does not exceed 24 °C and is safe for the patient. The optical scheme of the receiving unit and the transmitting module is presented. The optical model of the module is presented in the Zemax program. It is shown, that the required average optical power of the working spectral region is 235 μW for the four infrared LEDs and four photodiodes located at a distance of 1 meter. A description of the working layout of a visual display and data transmission device is presented, including a digital pulse sensor and blood oxygen level, a color control and data processing unit, a visual display device, and a data transmission unit. The LEDs operation modes and its compliance with the deviation of the controlled parameters were checked by a special microcontroller program of practical significance. The implementation of the developed system is relevant when monitoring the condition of the object of observation in cases where the use of the radio frequency range is limited and the stability of the data transmission channel to electromagnetic interference plays an important role.
- Open Access
- 1 April 2022
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 22 (2) , 401-409
Visual display system of changes in physiological state for patients with chronic disorders
There is an acute issue of patients recovering with chronic disorders in medicine of critical conditions — they are a vegetative and minimally consciousness state. Such states develop in patients after coma and are characterized by the presence of wakefulness with complete or almost complete absence of signs of purposeful behavior. Capturing small reflexes and body signs allows observing changes in the physiological state of the patient, the effectiveness of the treatment course and requires a continuous process, which is not always possible considering to the high workload of medical staff. In this regard, visual display and data transmission systems for patients are more efficient. The display device should be safe, mobile and not restrict the patient’s movement, should not have a negative impact on the patient. The display method should be intuitively understandable and clear for prompt decision-making. The main parts of the visual system are sensors of physiological signs on the patient’s body, a control module, a visual display object, and a data transmission module. RGB Arlight 5060 LED strips with pixel addressing on a textile substrate are used as display elements. The object of the visual display consists of three layers: a duvet cover on the underside, a wool blanket, a cotton backing with LED strips. The paper presents an assessment of the heating of the proposed visual display system for patients with chronic disorders and a comparison of the results with the maximum permissible heating of human skin. The heating estimation was performed by COMSOL Multiphysics cross-platform finite element analysis, solver, and multiphysics simulation. The simulation results are compared with an experimental study using a contact temperature meter Centre 304 and an infrared camera Optris PI 640i. The security of the system has been confirmed. Scenarios for the indicators to reduce the thermal impact are proposed. The proposed visual display system may be relevant when monitoring the physiological state of patients in Intensive Care Units. The implementation of the system will help to see changes in the physiological state and increase the chances of getting out of a chronic condition in the future.
- 1 April 2022
- Published by ITMO University in Scientific and Technical Journal of Information Technologies, Mechanics and Optics
- Vol. 22 (2) , 401-409
Open AccessVisual display system of changes in physiological state for patients with chronic disorders
There is an acute issue of patients recovering with chronic disorders in medicine of critical conditions — they are a vegetative and minimally consciousness state. Such states develop in patients after coma and are characterized by the presence of wakefulness with complete or almost complete absence of signs of purposeful behavior. Capturing small reflexes and body signs allows observing changes in the physiological state of the patient, the effectiveness of the treatment course and requires a continuous process, which is not always possible considering to the high workload of medical staff. In this regard, visual display and data transmission systems for patients are more efficient. The display device should be safe, mobile and not restrict the patient’s movement, should not have a negative impact on the patient. The display method should be intuitively understandable and clear for prompt decision-making. The main parts of the visual system are sensors of physiological signs on the patient’s body, a control module, a visual display object, and a data transmission module. RGB Arlight 5060 LED strips with pixel addressing on a textile substrate are used as display elements. The object of the visual display consists of three layers: a duvet cover on the underside, a wool blanket, a cotton backing with LED strips. The paper presents an assessment of the heating of the proposed visual display system for patients with chronic disorders and a comparison of the results with the maximum permissible heating of human skin. The heating estimation was performed by COMSOL Multiphysics cross-platform finite element analysis, solver, and multiphysics simulation. The simulation results are compared with an experimental study using a contact temperature meter Centre 304 and an infrared camera Optris PI 640i. The security of the system has been confirmed. Scenarios for the indicators to reduce the thermal impact are proposed. The proposed visual display system may be relevant when monitoring the physiological state of patients in Intensive Care Units. The implementation of the system will help to see changes in the physiological state and increase the chances of getting out of a chronic condition in the future.