MNMakiko Nishikawa

Makiko Nishikawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Makiko Nishikawa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Haruhiko Machida

    Department of Radiology, Tokyo Women’s Medical University Adachi Medical Center , 4-33-1 Kohoku, Adachi , Tokyo 123-8558, Japan

    2 shared publications
  • Hidenori Yamaguchi

    Department of Radiology, Tokyo Women’s Medical University Adachi Medical Center , 4-33-1 Kohoku, Adachi , Tokyo 123-8558, Japan

    2 shared publications
  • Toshiya Kariyasu

    Department of Radiology, Tokyo Women’s Medical University Adachi Medical Center , 4-33-1 Kohoku, Adachi , Tokyo 123-8558, Japan

    2 shared publications
  • Haruhiko Machida

    Department of Radiology, Tokyo Women’s Medical University, Adachi Medical Center

    1 shared publication
  • Keita Fukushima

    Department of Radiology, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan

    1 shared publication
  • Kenichi Yokoyama

    Department of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan

    1 shared publication

Latest Publications

  • Open Access

    Correlation between CT Value on Lung Subtraction CT and Radioactive Count on Perfusion Lung Single Photon Emission CT in Chronic Thromboembolic Pulmonary Hypertension

    by Toshiya Kariyasu, Haruhiko Machida, Tsuneo Yamashiro, Keita Fukushima, Masamichi Koyanagi, Kenichi Yokoyama, Makiko Nishikawa, Toru Satoh

    Background: Lung subtraction CT (LSCT), the subtraction of noncontrast CT from CT pulmonary angiography (CTPA) without spatial misregistration, is easily applicable by utilizing a software-based deformable image registration technique without additional hardware and permits the evaluation of lung perfusion as iodine accumulation, similar to that observed in perfusion lung single photon emission CT (PL-SPECT). The aim of this study was to use LSCT to newly assess the quantitative correlation between the CT value on LSCT and radioactive count on PL-SPECT as a reference and validate the quantification of lung perfusion by measuring the CT value in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: We prospectively enrolled 47 consecutive patients with CTEPH undergoing both LSCT and PL-SPECT; we used noncontrast CT, CTPA, and LSCT to measure CT values and PL-SPECT to measure radioactive counts in areas representing three different perfusion classes—no perfusion defect, subsegmental perfusion defect, and segmental perfusion defect; we compared CT values on noncontrast CT, CTPA, and LSCT and radioactive counts on PL-SPECT among the three classes, then assessed the correlation between them. Results: Both the CT values and radioactive counts differed significantly among the three classes (p < 0.01 for all) and showed weak correlation (ρ = 0.38) by noncontrast CT, moderate correlation (ρ = 0.61) by CTPA, and strong correlation (ρ = 0.76) by LSCT. Conclusions: The CT value measurement on LSCT is a novel quantitative approach to assess lung perfusion in CTEPH and only correlates strongly with radioactive count measurement on PL-SPECT.


  • Open Access

    Acute myocardial infarction identified by dual-energy cardiac computed tomography without additional contrast media injection immediately following catheter coronary angiography

    by Toshiya Kariyasu, Hidenori Yamaguchi, Makiko Nishikawa, Haruhiko Machida

    A 70-year-old man presenting with acute chest pain was transferred to our hospital. Emergent blood tests showed elevated levels of creatine kinase (CK; 691 IU/L; the reference range, 50–195 IU/L), CK-MB (54 IU/L; the reference range, 0–25 IU/L), and troponin I (35.18 ng/mL; the reference range, 0–0.06 ng/mL); however, no abnormalities were identified on electrocardiogram (ECG; Supplementary image online ) and transthoracic echocardiogram. Under a clinical diagnosis of acute coronary syndrome, emergent catheter coronary angiography (CCA) was performed using a total iodine contrast media (CM) dose of approximately 90 mL, but the culprit lesion could not be identified. Immediately following the CCA, ECG-gated cardiac dual-energy computed tomography (DECT) was performed without CM re-injection or any other special preparation. Iodine density imaging (Panels A and B) revealed late iodine enhancement (LIE) representing acute myocardial infarction (AMI) localized in the interventricular septum more clearly than virtual monochromatic imaging at 70 keV (Panels C and D), which offers similar image contrast to single-energy CT at 120 kVp. The CCA was reviewed to identify a contrast filling defect representing thrombus in the first septal branch (Panel E and see Supplementary data online , Video S1). Due to the small infarct size, the patient was conservatively treated. Three months later, cardiac magnetic resonance (CMR) confirmed late gadolinium enhancement (LGE) in the interventricular septum (Panels F and G), as also shown in the DECT.