YSYuxuan Song

Yuxuan Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuxuan Song has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Advanced Sensing Materials and Their Applications for Power Sensors

    by Weigen Chen, Yuxuan Song, Jun Hu, Xia Chen, Han Peng, Cheng He, Xing Fan, Wentao Zhang, Shijie Cheng

    The construction of new‐generation power systems imposes stringent requirements on the safety and reliability of critical equipment, making accurate state perception essential for grid security and digital transformation. Sensing materials fundamentally determine sensor performance in terms of sensitivity, bandwidth, environmental adaptability and intelligence. This paper systematically analyses the demands of new‐generation power systems on sensing materials across five dimensions: multiparameter, high‐sensitivity sensing, miniaturisation, high reliability, self‐powering and intelligence. It comprehensively reviews five major categories of advanced sensing materials—electromagnetic, optical waveguide, semiconductor, quantum and self‐powered materials—detailing their development, performance enhancement mechanisms and applications in monitoring key equipment parameters. The critical challenges facing engineering applications are examined, including cross‐sensitivity, long‐term stability and scalable fabrication. Future development trends towards intelligence, integration and multifunctionality are projected. This review concludes that innovation in sensing materials is fundamental to advancing power sensing technology and establishing a robust perception foundation for new‐generation power systems.

  • Open Access

    Quasi‐Distributed Static/Dynamic Strain Detection of Wind Turbine Blades Based on Fibre Bragg Grating Arrays Sensing

    by Zijie Tang, Hong Liu, Changding Wang, Yuxuan Song, Haoyuan Tian, Xuetao Duan, Weikai Zhang, Bingfei Zhang, Weigen Chen

    This paper presents a quasi‐distributed sensing method for wind turbine blade strain using fibre Bragg grating (FBG) arrays. The sensitive area of the blade strain variation is determined by simulation, and three fibre grating arrays are arranged on the surface of the sensitive part of the blade strain. Static experiments show that the strain is larger between 0.6 times blade length (0.6 R ) and 0.8 times blade length (0.8 R ), which is consistent with the simulation results. It is also found that the slopes of the strain versus load fitting curves are similar at different angles of attack, but the intercepts are different. The dynamic experiments show that the strain at 0.8 times blade length (0.8 R ) is the largest and changes most rapidly with time. The dynamic strain distribution is similar to the static experimental results. In this paper, the integration of quasi‐distributed strain sensing for wind turbine blades is explored, providing a new fibre optic detection technique for strain monitoring.


  • A novel fiber-optic implantable basin insulator and its detection of current-excited GIS vibration signals

    by Yuxuan Song, Anqi Tao, Weigen Chen, Weikai Zhang, Changding Wang, Xiaosong Zhu, Bo Liu, Haoyuan Tian, Hong Liu


  • 110 kV Power Cable External Disturbance Optical Fiber Sensing Detection and Identification Method Based on ResNeXt and Attention Mechanism

    by Haoyuan Tian, Jianxin Wang, Weikai Zhang, Hong Liu, Yuxuan Song, Weigen Chen

    Power cable is a core equipment for the operation of power transmission and distribution systems. Effective detection and identification of external disturbances of power cable is of great significance to the stable operation of power transmission and distribution systems. Optical fiber sensor has the characteristics of anti-electromagnetic interference and small size and is widely used in built-in detection of equipment. Based on 110kV power cable and optical fiber Mach-Zehnder interferometer, the signal difference between built-in optical fiber and external optical fiber is compared, and the effectiveness of built-in optical fiber detection is verified. Subsequently, the detection performance of built-in optical fiber under four different external disturbances is studied, and the signal denoising method based on Slime mould algorithm(SMA)-Variational Mode Decomposition(VMD) is used for the built-in optical fiber detection signal to obtain one-dimensional data with improved quality. The Gramian angular field is used for time-frequency joint analysis to expand the one-dimensional information into a two-dimensional image for ResNeXt to identify the type of external disturbance. By introducing the attention mechanism, the recognition rate of the system is improved. The results show that the best recognition index of the model can reach 98.35%. This method provides a new idea for the detection of external disturbances of intelligent power cables.


  • Top Cited Papers

    Pattern Recognition Method for Detecting Partial Discharge in Oil-Paper Insulation Equipment Using Optical F-P Sensor Array Based on KAN-CNN Algorithm

    by Hong Liu, Zhixian Zhang, Ruimin Song, Zhiqing Shu, Jianxin Wang, Haoyuan Tian, Yuxuan Song, Weigen Chen

    Ultrasound detection can promptly identify partial discharge (PD) faults inside power transformer by using fiber-optic Fabry-Perot (F-P) array sensors. This paper presents a new design scheme for a wideband acousto-optic direct-coupled F-P sensor. Indirect-coupled F-P sensors have a narrow, highly sensitive response region, and direct-coupled F-P sensors have a wide band response from 1 to 200 kHz. We constructed a PD database by simulating different PD signals in oil tank. We proposed learnable KAN kernel to replace traditional CNN kernel and introduced KAN as a replacement for the ReLU function. Furthermore, we conducted pattern recognition research with a convolutional depth of only 6 layers. The test accuracy on oil tank dataset reached 98.7% for KAN Convolution + ReLU and 99.5% for KAN Convolution + KAN. The validation accuracy achieved by inputting PD signals measured from a real 220 kV power transformer into the two models was 97.5% and 98.75%, respectively.


  • Top Cited Papers

    Comparison of Different Coupling Types of Fiber-Optic Fabry–Perot Ultrasonic Sensing for Detecting Partial Discharge Faults in Oil-Paper Insulated Equipment

    by Hong Liu, Zhixian Zhang, Haoyuan Tian, Yuxuan Song, Jianxin Wang, Zhiqing Shu, Weigen Chen

    Power transformer internal partial discharge fault detection is a guarantee for the safe operation of the power system, fiber optic F-P sensors are widely used in the partial discharge detection of power equipment due to the anti-electromagnetic interference, high sensitivity and can be built-in fault location. Based on two different types of sensing principles, F-P sensors are divided into two categories: F-P cavity length change (indirect-coupled F-P) and medium refractive index change (direct-coupled F-P). At present, most scholars focus on indirect-coupled F-P studies, and direct-coupled F-P sensors based on the change of refractive index of the medium are less studied. This paper focuses on the effect of fluid parameter variations on its internal spatial optical waveguide in the liquid-phase environment, revealing the acousto-optic direct-coupled F-P sensing mechanism in oil. Two types of F-P sensors were developed and the band characteristics, directional performance and sensitivity of F-P sensors were comparatively tested. The results show that the indirect-coupled F-P sensors have a narrow and highly sensitive response region, typically 20 kHz to 30 kHz, but are less directional and insensitive to lateral signals. Direct-coupled F-P sensors have a wide bandwidth, a wide dynamic range, a flat response in the 1 to 200 kHz range, and omnidirectional detectability. In this paper, a comparison of partial discharge fault detection of oil-paper insulation equipment was carried out using two types of F-P sensors. The results show that indirect-coupled F-P sensors detect partial discharges with partial signal distortion, while direct-coupled F-P sensors can effectively detect different types of partial discharge ultrasonic signals of oil-paper insulated equipment.


  • Top Cited Papers
    Open Access

    Ultrasonic localization method based on Chan‐WLS algorithm for detecting power transformer partial discharge faults by fibre optic F‐P sensing array

    by Hong Liu, Tianhe Yang, Zhixian Zhang, Haoyuan Tian, Yuxuan Song, Qiuxia Sun, Wei Wang, Yunjun Geng, Weigen Chen

    Fibre optic F‐P sensor has become one of the mainstream detection methods for partial discharge faults due to their advantages of good insulation, high sensitivity, resistance to electromagnetic interference, simple structure and inexpensive pricing. The first‐order resonant frequency of the acoustically sensitive diaphragm of the F‐P sensor is given based on the theory of plate and shell vibration, and the fibre optic F‐P sensing array is designed based on the Fabry–Perot interference principle. A sensor installation method is also proposed for introducing a fibre optic F‐P probe into the power transformer interior using a fibre optic penetrator through flange at the power transformer oil change valve. A system of non‐linear equations is developed by utilising the time difference of arrival (TDOA) of the partial discharge ultrasound signal propagation to the F‐P sensing array. The Chan‐WLS algorithm is used to convert the non‐linear equations in the TDOA localisation method into a non‐linear optimisation problem to be solved and experimentally verified on the 220 kV real power transformer. The experimental results show that the error in the partial discharge fault localisation is solved based on the Chan‐WLS algorithm and the actual location is 20.27 cm, which is within the acceptable error.


  • Distributed Partial Discharge Acoustic Signal Detection and Localization Technology for GIL With Built-in Fiber Optics

    by Yuxuan Song, Haoyuan Tian, Zongqing Jia, Weigen Chen, Weikai Zhang, Changding Wang, Tao Zhou, Litong Li, Deng Hong, Yan Wang, et al.

    Fiber optic distributed acoustic sensing (DAS) is a potential method to achieve partial discharge (PD) detection and fast localization in gas insulated metal enclosed transmission lines (GIL). In order to detect and locate the weak partial discharge signals in the GIL as early as possible, this paper proposes an integrated distributed fiber optic sensor installation method for the GIL, as well as a distributed partial discharge acoustic detection and localization system. Based on the fully insulating nature of the optical fiber, the optical fiber is installed inside the GIL to improve the sensitivity to partial discharge acoustic signals, and the length of the sensor unit is increased by repeated winding to further improve the detection performance of the acoustic signals. A true-to-life GIL partial discharge test platform was built to investigate the multi-point distributed sensing performance of the proposed coherent optical time domain reflectometer system for metal tip discharge. The test results show that the sensing distance of the sensing system can reach 120m, which can achieve the multipoint detection and localization of the partial discharge acoustic signal of 29.7pC. The proposed sensing method and system provide a new solution for GIL weak partial discharge optical fiber distributed acoustic signal detection.


  • Top Cited Papers

    Online multi-parameter sensing and condition assessment technology for power cables: A review

    by Yuxuan Song, Weigen Chen, Fu Wan, Zhixian Zhang, Lin Du, Pinyi Wang, Jian Li, Zhaoguo Wu, Huixian Huang