Haibiao Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haibiao Zheng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chaoju Yu
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Congju Yao
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Jianfei Tong
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Jie Chen
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
1 shared publication - Junye Yang
Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China
1 shared publication - Le Kang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication
Latest Publications
- Open Access
- 8 September 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (3) , 22
Development of a Cryogenic Load Frame for In Situ Neutron Diffraction
In recent years, an increasing number of national major projects have focused on the physicochemical properties of materials and the structural integrity of components in cryogenic environments. In situ neutron non-destructive testing offers a distinct advantage for scientific research conducted under cryogenic conditions. With the progressive advancement of neutron sources and neutron diffraction techniques, neutron probes have become indispensable for the in situ observation of lattice strain, phase transformation behavior, and residual stresses in materials at cryogenic temperatures. Based on the energy-resolved neutron imaging instrument (ERNI) at Beamline 13 of the China Spallation Neutron Source (CSNS), we have developed a cryogenic loading frame for in situ neutron diffraction tensile tests. This paper presents a detailed description of the mechanical structural design, cooling and control system, strength and thermal analyses, and experimental validation of the device. The apparatus enables in situ neutron diffraction experiments over a wide temperature range of 6–473 K, with an axial loading capacity of 50 kN. Furthermore, the device was employed to conduct in situ neutron diffraction measurements on austenitic 304 stainless steel at both room and cryogenic temperatures. The experimental results confirm that this equipment exhibits stable loading capability and precise temperature control, ensuring the reliability of the experimental data.
- 8 September 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (3) , 22
Open AccessDevelopment of a Cryogenic Load Frame for In Situ Neutron Diffraction
In recent years, an increasing number of national major projects have focused on the physicochemical properties of materials and the structural integrity of components in cryogenic environments. In situ neutron non-destructive testing offers a distinct advantage for scientific research conducted under cryogenic conditions. With the progressive advancement of neutron sources and neutron diffraction techniques, neutron probes have become indispensable for the in situ observation of lattice strain, phase transformation behavior, and residual stresses in materials at cryogenic temperatures. Based on the energy-resolved neutron imaging instrument (ERNI) at Beamline 13 of the China Spallation Neutron Source (CSNS), we have developed a cryogenic loading frame for in situ neutron diffraction tensile tests. This paper presents a detailed description of the mechanical structural design, cooling and control system, strength and thermal analyses, and experimental validation of the device. The apparatus enables in situ neutron diffraction experiments over a wide temperature range of 6–473 K, with an axial loading capacity of 50 kN. Furthermore, the device was employed to conduct in situ neutron diffraction measurements on austenitic 304 stainless steel at both room and cryogenic temperatures. The experimental results confirm that this equipment exhibits stable loading capability and precise temperature control, ensuring the reliability of the experimental data.
- Open Access
Comparative Research on Ventilation Characteristics of Scattering and Sample Room from Chinese Spallation Neutron Source
Ventilation design of the scattering room and sample room in the Chinese Spallation Neutron Source (CSNS) is of great significance to maintain good indoor air quality and ensure the health of radiation workers. Based on the computational fluid dynamics (CFD) theory, the three-dimensional models of the scattering and sample rooms were established and fourteen layout schemes were simulated. Subsequently, the best schemes were selected among three typical layout schemes. On this basis, the paper presents research about the influence of changing the height of the outlet on the ventilation quality. The results show that the trend of numerical simulation is consistent with experimental data, which verifies the reliability of the numerical method. The change of the exhaust port position has an apparent influence on indoor ventilation, which reduces the air age by 4–27%. When the position of the outlet descends 0.5 m, the air age decreases by 2–11%, and this study provides guidance and suggestions for the design of the scattering and sample rooms.
Open AccessComparative Research on Ventilation Characteristics of Scattering and Sample Room from Chinese Spallation Neutron Source
Ventilation design of the scattering room and sample room in the Chinese Spallation Neutron Source (CSNS) is of great significance to maintain good indoor air quality and ensure the health of radiation workers. Based on the computational fluid dynamics (CFD) theory, the three-dimensional models of the scattering and sample rooms were established and fourteen layout schemes were simulated. Subsequently, the best schemes were selected among three typical layout schemes. On this basis, the paper presents research about the influence of changing the height of the outlet on the ventilation quality. The results show that the trend of numerical simulation is consistent with experimental data, which verifies the reliability of the numerical method. The change of the exhaust port position has an apparent influence on indoor ventilation, which reduces the air age by 4–27%. When the position of the outlet descends 0.5 m, the air age decreases by 2–11%, and this study provides guidance and suggestions for the design of the scattering and sample rooms.