Yanfeng Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanfeng Yao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yonghong Wang
Hefei University of Technology
3 shared publications - Biao Wang
Hefei University of Technology, School of Instrument Science and Opto-Electronics Engineering, Hefei, China
2 shared publications - Fenglong Yang
China Acad Space Technol, Beijing, China
1 shared publication - Junrui Li
School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, Anhui 230009, People’s Republic of China
1 shared publication - Mohan Ding
School of Instrument Science and Optoelectronic Engineering, Hefei University of Technology, Hefei, China
1 shared publication - Peizheng Yan
School of Instrument Science and Optoelectronic Engineering, Hefei University of Technology, Hefei, China
1 shared publication
Latest Publications
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
High-Performance Rotational Shearography System Based on Dove Prism for Nondestructive Testing
Digital shearography (DS) is a nondestructive testing method that provides full-field measurement, with its sensitive direction closely related to shearing direction and its sensitivity related to the shearing amount. Conventional single-direction DS carries the risk of missed detection of defects, while conventional two- or multidirectional DS struggles to balance both rapid measurement and high-quality measurement results. To avoid missed detection of defects and achieve high-performance measurement, we have designed a novel rotational shearography system that can perform defect detection with just a single temporal phase shift (TPS). The system introduces rotational shearing amount using a dove prism (D), effectively preventing missed detections caused by the insensitivity of defect shapes to the shearing direction. A 4f system is embedded in the measurement system to overcome the limitations imposed by optical components on the field of view (FOV), allowing the system to work in a large range of FOV. We constructed an experimental setup to evaluate the performance of the proposed system. The measurement results not only demonstrate the system’s applicability for various loading conditions and defect shapes but also verify its feasibility in both large and tiny FOV measurements.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
High-Performance Rotational Shearography System Based on Dove Prism for Nondestructive Testing
Digital shearography (DS) is a nondestructive testing method that provides full-field measurement, with its sensitive direction closely related to shearing direction and its sensitivity related to the shearing amount. Conventional single-direction DS carries the risk of missed detection of defects, while conventional two- or multidirectional DS struggles to balance both rapid measurement and high-quality measurement results. To avoid missed detection of defects and achieve high-performance measurement, we have designed a novel rotational shearography system that can perform defect detection with just a single temporal phase shift (TPS). The system introduces rotational shearing amount using a dove prism (D), effectively preventing missed detections caused by the insensitivity of defect shapes to the shearing direction. A 4f system is embedded in the measurement system to overcome the limitations imposed by optical components on the field of view (FOV), allowing the system to work in a large range of FOV. We constructed an experimental setup to evaluate the performance of the proposed system. The measurement results not only demonstrate the system’s applicability for various loading conditions and defect shapes but also verify its feasibility in both large and tiny FOV measurements.
- 31 January 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 176
High-performance digital shearography integrating spatial light modulator with micro-polarizer camera
- 31 January 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 176
High-performance digital shearography integrating spatial light modulator with micro-polarizer camera
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
A Synchronous Measurement System for the First Derivative of Out-of-Plane Deformation of Double Ends
In current practical applications, synchronously obtaining the information about out-of-plane deformation of double ends is often necessary. However, traditional measurement systems cannot achieve the synchronous measurement of double ends, as two sets of measurement systems are often needed. This study solves the problem by designing a synchronous measurement system for the first derivative of the double-end deformation based on shearography. The first derivative distribution of the double-end deformation is measured synchronically by imaging the two end surfaces in different areas of the camera’s target plane through different shear structures. In addition, by placing apertures in each Michelson shear structure, the synchronous dynamic measurement of both ends and the independent adjustment of the shear and spectral distribution in the Michelson shearography system are realized. The principle of the measurement system is introduced in detail, and the feasibility and practicability of the proposed system are verified by experiments.
- 3 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
A Synchronous Measurement System for the First Derivative of Out-of-Plane Deformation of Double Ends
In current practical applications, synchronously obtaining the information about out-of-plane deformation of double ends is often necessary. However, traditional measurement systems cannot achieve the synchronous measurement of double ends, as two sets of measurement systems are often needed. This study solves the problem by designing a synchronous measurement system for the first derivative of the double-end deformation based on shearography. The first derivative distribution of the double-end deformation is measured synchronically by imaging the two end surfaces in different areas of the camera’s target plane through different shear structures. In addition, by placing apertures in each Michelson shear structure, the synchronous dynamic measurement of both ends and the independent adjustment of the shear and spectral distribution in the Michelson shearography system are realized. The principle of the measurement system is introduced in detail, and the feasibility and practicability of the proposed system are verified by experiments.