Jonathan Bilko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan Bilko has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alexander K. Glaros
Comprehensive Sickle Cell Center, Children’s Hospital of Michigan, Detroit, MI 48201, USA
1 shared publication - Ariel Washington
Department of Oncology, School of Medicine, Wayne State University, Detroit, MI 48201, USA
1 shared publication - Megan Faucett
Department of Medical Laboratory Science, Eugene Applebaum College of Pharmacy and Health Sciences, Wayne State University, Detroit, MI 48201, USA
1 shared publication - Meghna Shukla
College of Nursing, Wayne State University
1 shared publication - Navdeep Singh
College of Nursing, Wayne State University, Detroit, MI 48202, USA
1 shared publication - Ramona A. Benkert
College of Nursing, Wayne State University, Detroit, MI, USA
1 shared publication
Latest Publications
- Open Access
- 20 April 2026
- Published by Open Exploration Publishing in Exploration of Medicine
- Vol. 7, 1001400
Medical mistrust and sickle cell disease: a systematic review
Background: Sickle cell disease (SCD) is a group of heritable conditions with significant morbidity, burden of disease management and healthcare delivery issues. Medical mistrust (MM) is a psychological outcome of healthcare delivery issues. The purpose of this review was to assess the concept of MM in the literature on SCD, summarize the findings and gaps, and was guided by three questions: 1) How has MM been measured and/or described in patients with SCD? 2) What factors have been described in the literature that predispose patients with SCD to develop MM? 3) What consequences or outcomes have been described because of MM in patients with SCD? Methods: The methodological framework of Arksey and O’Malley was used to review articles from PubMed, Scopus, Web of Science, CINAHL, PsycInfo, and EMBASE. Inclusion criteria were quantitative, qualitative, and mixed methods peer-reviewed studies published in English between 1994 and 2025; articles focused on patients with SCD and those that described concepts found in the existing MM instruments. Results: Forty-two studies were included; 26 were strictly qualitative, 11 were mixed methods, and 5 were strictly quantitative. No study used an existing MM measure; yet concepts from MM measures were described: group disparities and suspicion. Negative healthcare staff communication, poor pain control, transition of care, and lack of provider transparency predisposed patients toward MM. Outcomes of MM included avoidance of care, nonadherence, psychological distress, and maladaptive coping. Discussion: This review highlights the predictors and outcomes of MM in patients with SCD and identifies the notable gaps in the state of the SCD MM literature. More studies are needed to assess the development and consequences of MM in patients with SCD. The findings highlight the experiences of patients with SCD and offer researchers insights into possible interventions to decrease MM and improve outcomes.
- 20 April 2026
- Published by Open Exploration Publishing in Exploration of Medicine
- Vol. 7, 1001400
Open AccessMedical mistrust and sickle cell disease: a systematic review
Background: Sickle cell disease (SCD) is a group of heritable conditions with significant morbidity, burden of disease management and healthcare delivery issues. Medical mistrust (MM) is a psychological outcome of healthcare delivery issues. The purpose of this review was to assess the concept of MM in the literature on SCD, summarize the findings and gaps, and was guided by three questions: 1) How has MM been measured and/or described in patients with SCD? 2) What factors have been described in the literature that predispose patients with SCD to develop MM? 3) What consequences or outcomes have been described because of MM in patients with SCD? Methods: The methodological framework of Arksey and O’Malley was used to review articles from PubMed, Scopus, Web of Science, CINAHL, PsycInfo, and EMBASE. Inclusion criteria were quantitative, qualitative, and mixed methods peer-reviewed studies published in English between 1994 and 2025; articles focused on patients with SCD and those that described concepts found in the existing MM instruments. Results: Forty-two studies were included; 26 were strictly qualitative, 11 were mixed methods, and 5 were strictly quantitative. No study used an existing MM measure; yet concepts from MM measures were described: group disparities and suspicion. Negative healthcare staff communication, poor pain control, transition of care, and lack of provider transparency predisposed patients toward MM. Outcomes of MM included avoidance of care, nonadherence, psychological distress, and maladaptive coping. Discussion: This review highlights the predictors and outcomes of MM in patients with SCD and identifies the notable gaps in the state of the SCD MM literature. More studies are needed to assess the development and consequences of MM in patients with SCD. The findings highlight the experiences of patients with SCD and offer researchers insights into possible interventions to decrease MM and improve outcomes.
- Open Access
- 2 June 2022
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (9) , 1665-1671
Determination of cocaine on banknotes using innovative sample preparation coupled with multiple calibration techniques
A method using innovative sample preparation was developed for determination of cocaine on banknotes. Aqueous extraction of cocaine from banknotes was performed using a sonication‐enhanced technique. Quantitation of cocaine was achieved using high performance liquid chromatography (HPLC) with UV detection at 230 nm, whereas identification was accomplished utilizing gas chromatography with mass spectrometry (GC‐MS). Multiple calibration techniques, including the external calibration method (ECM), internal standard method (ISM), and standard addition method (SAM) were incorporated into the experimental design to simultaneously determine cocaine contents and assess matrix effects. Statistical paired t tests confirmed that matrix effects were not significant with the sample preparation employed. No damage to the features of the banknotes was observed from the extraction procedure. Extraction efficiency, spike recovery, and detection limit were also determined. The unique experimental design allowed for ECM, ISM, and SAM to concurrently determine the contents of cocaine on banknotes collected around Metro‐Detroit. The concentration range of cocaine was from 1.58 to 14.7 μg per note, with an average of 6.96 μg per note. The method is simple and suitable for drug analysis and forensic science applications.
- 2 June 2022
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (9) , 1665-1671
Open AccessDetermination of cocaine on banknotes using innovative sample preparation coupled with multiple calibration techniques
A method using innovative sample preparation was developed for determination of cocaine on banknotes. Aqueous extraction of cocaine from banknotes was performed using a sonication‐enhanced technique. Quantitation of cocaine was achieved using high performance liquid chromatography (HPLC) with UV detection at 230 nm, whereas identification was accomplished utilizing gas chromatography with mass spectrometry (GC‐MS). Multiple calibration techniques, including the external calibration method (ECM), internal standard method (ISM), and standard addition method (SAM) were incorporated into the experimental design to simultaneously determine cocaine contents and assess matrix effects. Statistical paired t tests confirmed that matrix effects were not significant with the sample preparation employed. No damage to the features of the banknotes was observed from the extraction procedure. Extraction efficiency, spike recovery, and detection limit were also determined. The unique experimental design allowed for ECM, ISM, and SAM to concurrently determine the contents of cocaine on banknotes collected around Metro‐Detroit. The concentration range of cocaine was from 1.58 to 14.7 μg per note, with an average of 6.96 μg per note. The method is simple and suitable for drug analysis and forensic science applications.