Emanuele Franchi
Emanuele Franchi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Filippo Maria Anghilieri
Orthopedic and Trauma Residency Program, University of Milan, 20122 Milan, Italy
2 shared publications - Ilaria Mariani
Institute for Maternal and Child Health IRCCS Burlo Garofolo, Trieste, Italy
2 shared publications - Katia Corona
Department of Medicine and Health Sciences “Vincenzo Tiberio”, University of Molise, Via Giovanni Paolo II, 86100 Campobasso, Italy
2 shared publications - Lorenzo Monti
Istituto Clinico Villa Aprica, GSD, Como, Italy
2 shared publications - Nicola Ursino
IRCCS Orthopedic Institute Galeazzi, Milan, Italy
2 shared publications - Riccardo D’aMbrosi
IRCCS Ospedale Galeazzi - Sant’Ambrogio, Milan, Italy
2 shared publications
Latest Publications
- Open Access
- 1 July 2022
- Vol. 93 (3) , e2022160
Hypoallergenic unicompartmental knee arthroplasty and return to sport: comparison between Oxidized Zirconium and Titanium Niobium Nitride.
The present study aims to compare the rate of return to sports in patients who underwent surgery for mobile-bearing UKA with either hypoallergenic TiNbN or with oxidized zirconium alloy implants. The records of two consecutive cohorts for a total of 90 hypoallergenic implants were prospectively analysed. The first cohort consisted of 41 consecutive series of medial mobile-bearing hypoallergenic TiNbN UKA, whereas the second cohort consisted of 49 consecutive medial fixed-bearing hypoallergenic Uni Oxinium.The clinical evaluation involved evaluating each patient's University of California, Los Angeles (UCLA) activity scoresand the High-Activity Arthroplasty Score(HAAS). Each patient was clinically evaluated on the day before surgery (T0), then after a minimum follow-up period of 12 months (T1), and finally after 24 months (T2). Results:The only pre-operative difference between the two groups involved pre-operative BMI with significantly higher BMI in TiNbN Group (p<0.001). Both groups reported significant improvement at each follow-up compared with the previous and also at the final follow up with respect to UCLA and HAAS (p0.05). Moreover, BMI improved significantly at the final follow up, but only in TiNbN group (p<0.05). Both TiNbN and Oxinium UKA procedures enabled patients to return to an acceptable level of sports activity with excellent radiographic outcomes after the final follow up regardless of the age, gender, BMI, and bearing type.
- 1 July 2022
- Vol. 93 (3) , e2022160
Open AccessHypoallergenic unicompartmental knee arthroplasty and return to sport: comparison between Oxidized Zirconium and Titanium Niobium Nitride.
The present study aims to compare the rate of return to sports in patients who underwent surgery for mobile-bearing UKA with either hypoallergenic TiNbN or with oxidized zirconium alloy implants. The records of two consecutive cohorts for a total of 90 hypoallergenic implants were prospectively analysed. The first cohort consisted of 41 consecutive series of medial mobile-bearing hypoallergenic TiNbN UKA, whereas the second cohort consisted of 49 consecutive medial fixed-bearing hypoallergenic Uni Oxinium.The clinical evaluation involved evaluating each patient's University of California, Los Angeles (UCLA) activity scoresand the High-Activity Arthroplasty Score(HAAS). Each patient was clinically evaluated on the day before surgery (T0), then after a minimum follow-up period of 12 months (T1), and finally after 24 months (T2). Results:The only pre-operative difference between the two groups involved pre-operative BMI with significantly higher BMI in TiNbN Group (p<0.001). Both groups reported significant improvement at each follow-up compared with the previous and also at the final follow up with respect to UCLA and HAAS (p0.05). Moreover, BMI improved significantly at the final follow up, but only in TiNbN group (p<0.05). Both TiNbN and Oxinium UKA procedures enabled patients to return to an acceptable level of sports activity with excellent radiographic outcomes after the final follow up regardless of the age, gender, BMI, and bearing type.
- 29 May 2022
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 33 (4) , 1315-1328
Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy
Background The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. Methods The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient’s Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). Results The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. Conclusions Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. Level of evidence: Level II Comparative study.
- 29 May 2022
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 33 (4) , 1315-1328
Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy
Background The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing unicompartmental knee arthroplasty (UKA) with either titanium niobium nitride (TiNbN) alloy implants or with fixed-bearing oxidized zirconium alloy implants. Methods The records of two consecutive cohorts for a total of 86 hypoallergenic implants were prospectively analyzed. The first cohort consisted of 49 consecutive implantations of the hypoallergenic UKA Journey Uni Oxinium (Ox Group), while the second consisted of 37 consecutive series of UKA Oxford (TiNbN Group). All patients were evaluated by two independent surgeons who were not involved in the index surgery. The clinical evaluation consisted of evaluating each patient’s Oxford Knee Score and Knee Society Score day before surgery (T0), and with two consecutive follow-ups at T1 (minimum follow-up 9 months) and T2 (minimum follow-up 24 months). Results The two groups were homogeneous in all preoperative values, except Body Mass Index (BMI) and duration of final follow-up [both statistically higher (p < 0.05) in the TiNbN group]. Both groups showed a clinically significant improvement for all scores at final follow-up (p < 0.05). The only differences between the two groups involved a higher pre-operative Oxford Score in TiNbN group (p = 0.031), and different tibial and femoral angles at the final follow-up. Conclusions Both TiNbN and Oxinium UKA procedures enabled patients from good to excellent clinical and radiographic outcomes after the final follow-up, regardless of the age, gender, BMI bearing type, and implant size. Level of evidence: Level II Comparative study.