Kornel Schadl
Research Subjects
Kornel Schadl has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jessica Rose
Division of Pediatric Orthopaedics, Stanford University School of Medicine, Stanford, CA, United States
2 shared publications - Sung Eun Kim
Stanford Medicine Children’s Health
2 shared publications - Alexander Wilder Richards
Department of Orthopaedic Surgery, Stanford University, Stanford, CA 94305, USA
1 shared publication - Amy L. Ladd
Department of Orthopaedic Surgery, Stanford University, Stanford, CA 94305, USA
1 shared publication - Elise Wang
School of Medicine, University of Rochester, Rochester, NY 14642, USA
1 shared publication - Frezghi Habte
Molecular Imaging Program at Stanford (MIPS), Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA
1 shared publication
Latest Publications
- 8 August 2024
- Published by Springer Nature
- p. 9-16
Graphical Modeling of the Lower-Limb Joint Motion from the Dynamic Floor Responses Under Footstep Forces
- 8 August 2024
- Published by Springer Nature
- p. 9-16
Graphical Modeling of the Lower-Limb Joint Motion from the Dynamic Floor Responses Under Footstep Forces
- Open Access
Validation of Inertial Measurement Units for Analyzing Golf Swing Rotational Biomechanics
Training devices to enhance golf swing technique are increasingly in demand. Golf swing biomechanics are typically assessed in a laboratory setting and not readily accessible. Inertial measurement units (IMUs) offer improved access as they are wearable, cost-effective, and user-friendly. This study investigates the accuracy of IMU-based golf swing kinematics of upper torso and pelvic rotation compared to lab-based 3D motion capture. Thirty-six male and female professional and amateur golfers participated in the study, nine in each sub-group. Golf swing rotational kinematics, including upper torso and pelvic rotation, pelvic rotational velocity, S-factor (shoulder obliquity), O-factor (pelvic obliquity), and X-factor were compared. Strong positive correlations between IMU and 3D motion capture were found for all parameters; Intraclass Correlations ranged from 0.91 (95% confidence interval [CI]: 0.89, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation; Pearson coefficients ranged from 0.92 (95% CI: 0.92, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation (p < 0.001 for all). Bland–Altman analysis demonstrated good agreement between the two methods; absolute mean differences ranged from 0.61 to 1.67 degrees. Results suggest that IMUs provide a practical and viable alternative for golf swing analysis, offering golfers accessible and wearable biomechanical feedback to enhance performance. Furthermore, integrating IMUs into golf coaching can advance swing analysis and personalized training protocols. In conclusion, IMUs show significant promise as cost-effective and practical devices for golf swing analysis, benefiting golfers across all skill levels and providing benchmarks for training.
Open AccessValidation of Inertial Measurement Units for Analyzing Golf Swing Rotational Biomechanics
Training devices to enhance golf swing technique are increasingly in demand. Golf swing biomechanics are typically assessed in a laboratory setting and not readily accessible. Inertial measurement units (IMUs) offer improved access as they are wearable, cost-effective, and user-friendly. This study investigates the accuracy of IMU-based golf swing kinematics of upper torso and pelvic rotation compared to lab-based 3D motion capture. Thirty-six male and female professional and amateur golfers participated in the study, nine in each sub-group. Golf swing rotational kinematics, including upper torso and pelvic rotation, pelvic rotational velocity, S-factor (shoulder obliquity), O-factor (pelvic obliquity), and X-factor were compared. Strong positive correlations between IMU and 3D motion capture were found for all parameters; Intraclass Correlations ranged from 0.91 (95% confidence interval [CI]: 0.89, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation; Pearson coefficients ranged from 0.92 (95% CI: 0.92, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation (p < 0.001 for all). Bland–Altman analysis demonstrated good agreement between the two methods; absolute mean differences ranged from 0.61 to 1.67 degrees. Results suggest that IMUs provide a practical and viable alternative for golf swing analysis, offering golfers accessible and wearable biomechanical feedback to enhance performance. Furthermore, integrating IMUs into golf coaching can advance swing analysis and personalized training protocols. In conclusion, IMUs show significant promise as cost-effective and practical devices for golf swing analysis, benefiting golfers across all skill levels and providing benchmarks for training.
- Open Access
- 30 May 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1453-1462
Web-Based Application for Biomedical Image Registry, Analysis, and Translation (BiRAT)
Imaging has become an invaluable tool in preclinical research for its capability to non-invasively detect and monitor disease and assess treatment response. With the increased use of preclinical imaging, large volumes of image data are being generated requiring critical data management tools. Due to proprietary issues and continuous technology development, preclinical images, unlike DICOM-based images, are often stored in an unstructured data file in company-specific proprietary formats. This limits the available DICOM-based image management database to be effectively used for preclinical applications. A centralized image registry and management tool is essential for advances in preclinical imaging research. Specifically, such tools may have a high impact in generating large image datasets for the evolving artificial intelligence applications and performing retrospective analyses of previously acquired images. In this study, a web-based server application is developed to address some of these issues. The application is designed to reflect the actual experimentation workflow maintaining detailed records of both individual images and experimental data relevant to specific studies and/or projects. The application also includes a web-based 3D/4D image viewer to easily and quickly view and evaluate images. This paper briefly describes the initial implementation of the web-based application.
- 30 May 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1453-1462
Open AccessWeb-Based Application for Biomedical Image Registry, Analysis, and Translation (BiRAT)
Imaging has become an invaluable tool in preclinical research for its capability to non-invasively detect and monitor disease and assess treatment response. With the increased use of preclinical imaging, large volumes of image data are being generated requiring critical data management tools. Due to proprietary issues and continuous technology development, preclinical images, unlike DICOM-based images, are often stored in an unstructured data file in company-specific proprietary formats. This limits the available DICOM-based image management database to be effectively used for preclinical applications. A centralized image registry and management tool is essential for advances in preclinical imaging research. Specifically, such tools may have a high impact in generating large image datasets for the evolving artificial intelligence applications and performing retrospective analyses of previously acquired images. In this study, a web-based server application is developed to address some of these issues. The application is designed to reflect the actual experimentation workflow maintaining detailed records of both individual images and experimental data relevant to specific studies and/or projects. The application also includes a web-based 3D/4D image viewer to easily and quickly view and evaluate images. This paper briefly describes the initial implementation of the web-based application.