EMEhsan Abouee Mehrizi

Ehsan Abouee Mehrizi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ehsan Abouee Mehrizi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Ali Asghar Ebrahimi

    Department of Environmental Health Engineering, Environmental Science and Technology Research Center, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

    1 shared publication
  • Ali Asghar Ebrahimi

    Shahid Sadoughi University of Medical Sciences

    1 shared publication
  • Alireza Abbasi

    Department of Environmental Health, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran

    1 shared publication
  • Amin Mohammadpour

    Department of Environmental Health, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran

    1 shared publication
  • Amir Zahedi

    Air Pollution and Respiratory Diseases Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

    1 shared publication
  • Ebrahim Shahsavani

    Department of Environmental Health Engineering, Environmental Science and Technology Research Center, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

    1 shared publication

Latest Publications

  • Investigating volatile organic compounds and modeling their dispersion from agriculture and industry in Dabal Khazaei, Ahvaz, Iran

    by Kosar Salemi, Amir Zahedi, Ali Asghar Ebrahimi, Mahdi Ghorbanian, Zahra Soltanianzadeh, Ehsan Abouee Mehrizi

    Background: The present study was conducted to investigate the type, concentration, and modeling of the emission of odorous volatile organic compounds (VOCs) caused by the industry in Dabal Khazai with AERMOD software to determine whether the activity of this industry affected the residential community or not. Methods: In this study, volatile compounds were collected in Tedlar bags and analyzed by gas chromatography-mass spectrometry (GC-MS). The emission rate of pollutants from sources is calculated using a combination of different equations. This calculation method is suitable for industrial sources that do not have primary data to calculate the amount of pollutant emissions. Results: The results analysis identified 59 VOCS and determined that ketene and methane are the most important pollutants in industrial source samples. The highest release rate is 3460 g/s of ketene gas for vinasse ponds, and the lowest one is for methane gas from the primary processing unit of the sugarcane plant in the sugarcane factory. The dispersion model showed that the emission radius of concentrations higher than the standard level is only at a distance of 10 km compared to industrial sources. Conclusion: The investigated industrial sources are not the origin of the bad smell in Ahvaz city. As a result, more research is needed to determine the bad smell in the city.

  • Open Access

    Real and Synthetic Greywater Treatment by a Combined Process of Ozonation, Granular Activated Carbon, and Ultrafiltration

    by Ebrahim Shahsavani, Mohammad Hassan Ehrampoush, Mohammad Reza Samaei, Ehsan Abouee Mehrizi, Farzan Madadizadeh, Alireza Abbasi, Mahboubeh Shiranian, Amin Mohammadpour, Ali Asghar Ebrahimi

    Background: The water crisis in different parts of the world forces people to manage water resources. Greywater can be used to reduce water stress. The annual rainfall average in Iran is hardly one-third of the world. In this study, the treatment of synthetic greywater at low, medium, and high organic load and real greywater (RGW) by a combined process of ozonation/granular activated carbon (GAC)/ultrafiltration (UF) have been investigated. Objectives: This study aimed to find a greywater treatment method that is effective, new, environment-friendly, and cost-effective. Methods: Chemicals and commercial compounds were used to prepare synthetic greywater, and the research pilot was developed. After several preparation steps, the GAC was transferred to a GAC reactor. A continuous flow of synthetic greywater entered the treatment system with low: 6.1, medium: 12.2, and high: 18.3 gCOD/L.d organic loading rates for 6 months. Next, the RGW samples from a residential complex in Shiraz, Iran, entered the treatment system for two weeks. After chemical analysis, an analysis of variance was carried out to compare the removal efficiency of parameters: [chemical oxygen demand (COD), five-day biochemical oxygen demand (BOD5), turbidity, and linear alkylbenzene sulfonates (LAS)] at various organic loads (low, medium, and high) of synthetic greywater and RGW. Results: We found the average COD removal in low, medium, and high organic loads of synthetic greywater and RGW as approximately 79.3%, 86.1%, 77.3%, and 97.3%, respectively. Moreover, the average BOD5 removal in the mentioned groups was about 69.6%, 48.9%, 42.7%, and 86.8%, respectively. The average of turbidity removal was 95.6%, 98.3%, 97.4%, and 97.9%, and average LAS removal was 90.1%, 88.9%, 88.3%, and 91.9%, respectively. Conclusions: This treatment method is remarkable for real and synthetic greywater treatment. It can effectively remove COD, BOD5, turbidity, and LAS. In addition, it is a relatively low-cost and environment-friendly system. Therefore, it can be recommended as a greywater treatment method, especially in countries with inadequate water supplies, such as Iran.