Fengxin Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fengxin Xie has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Guorong Huang
Department of Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
3 shared publications - Huiyan Tian
Department of Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
3 shared publications - Jia Shi
Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, China
3 shared publications - Weiling Fu
Department of Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
3 shared publications - Xiang Yang
Department of Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing 400038, China
3 shared publications - Marc Lamy de la Chapelle
Interdisciplinary Research Institute on Bio-Nano-Sciences, Babes-Bolyai University, Treboniu Laurian Street, 400271 Cluj-Napoca, Romania
2 shared publications
Latest Publications
- Open Access
- 31 October 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (11) , 721
Correction: He et al. A Novel Optical Fiber Terahertz Biosensor Based on Anti-Resonance for the Rapid and Nondestructive Detection of Tumor Cells. Biosensors 2023, 13, 947
- 31 October 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (11) , 721
Open AccessCorrection: He et al. A Novel Optical Fiber Terahertz Biosensor Based on Anti-Resonance for the Rapid and Nondestructive Detection of Tumor Cells. Biosensors 2023, 13, 947
- Open Access
- 23 October 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (10) , 947
A Novel Optical Fiber Terahertz Biosensor Based on Anti-Resonance for the Rapid and Nondestructive Detection of Tumor Cells
The sensitive and accurate detection of tumor cells is essential for successful cancer therapy and improving cancer survival rates. However, current tumor cell detection technologies have some limitations for clinical applications due to their complexity, low specificity, and high cost. Herein, we describe the design of a terahertz anti-resonance hollow core fiber (THz AR-HCF) biosensor that can be used for tumor cell detection. Through simulation and experimental comparisons, the low-loss property of the THz AR-HCF was verified, and the most suitable fiber out of multiple THz AR-HCFs was selected for biosensing applications. By measuring different cell numbers and different types of tumor cells, a good linear relationship between THz transmittance and the numbers of cells between 10 and 106 was found. Meanwhile, different types of tumor cells can be distinguished by comparing THz transmission spectra, indicating that the biosensor has high sensitivity and specificity for tumor cell detection. The biosensor only required a small amount of sample (as low as 100 μL), and it enables label-free and nondestructive quantitative detection. Our flow cytometry results showed that the cell viability was as high as 98.5 ± 0.26% after the whole assay process, and there was no statistically significant difference compared with the negative control. This study demonstrates that the proposed THz AR-HCF biosensor has great potential for the highly sensitive, label-free, and nondestructive detection of circulating tumor cells in clinical samples.
- 23 October 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (10) , 947
Open AccessA Novel Optical Fiber Terahertz Biosensor Based on Anti-Resonance for the Rapid and Nondestructive Detection of Tumor Cells
The sensitive and accurate detection of tumor cells is essential for successful cancer therapy and improving cancer survival rates. However, current tumor cell detection technologies have some limitations for clinical applications due to their complexity, low specificity, and high cost. Herein, we describe the design of a terahertz anti-resonance hollow core fiber (THz AR-HCF) biosensor that can be used for tumor cell detection. Through simulation and experimental comparisons, the low-loss property of the THz AR-HCF was verified, and the most suitable fiber out of multiple THz AR-HCFs was selected for biosensing applications. By measuring different cell numbers and different types of tumor cells, a good linear relationship between THz transmittance and the numbers of cells between 10 and 106 was found. Meanwhile, different types of tumor cells can be distinguished by comparing THz transmission spectra, indicating that the biosensor has high sensitivity and specificity for tumor cell detection. The biosensor only required a small amount of sample (as low as 100 μL), and it enables label-free and nondestructive quantitative detection. Our flow cytometry results showed that the cell viability was as high as 98.5 ± 0.26% after the whole assay process, and there was no statistically significant difference compared with the negative control. This study demonstrates that the proposed THz AR-HCF biosensor has great potential for the highly sensitive, label-free, and nondestructive detection of circulating tumor cells in clinical samples.
- Open Access
- 31 May 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (6) , 378
THz-ATR Spectroscopy Integrated with Species Recognition Based on Multi-Classifier Voting for Automated Clinical Microbial Identification
The demand for rapid and accurate identification of microorganisms is growing due to considerable importance in all areas related to public health and safety. Here, we demonstrate a rapid and label-free strategy for the identification of microorganisms by integrating terahertz-attenuated total reflection (THz-ATR) spectroscopy with an automated recognition method based on multi-classifier voting. Our results show that 13 standard microbial strains can be classified into three different groups of microorganisms (Gram-positive bacteria, Gram-negative bacteria, and fungi) by THz-ATR spectroscopy. To detect clinical microbial strains with better differentiation that accounts for their greater sample heterogeneity, an automated recognition algorithm is proposed based on multi-classifier voting. It uses three types of machine learning classifiers to identify five different groups of clinical microbial strains. The results demonstrate that common microorganisms, once time-consuming to distinguish by traditional microbial identification methods, can be rapidly and accurately recognized using THz-ATR spectra in minutes. The proposed automatic recognition method is optimized by a spectroscopic feature selection algorithm designed to identify the optimal diagnostic indicator, and the combination of different machine learning classifiers with a voting scheme. The total diagnostic accuracy reaches 80.77% (as high as 99.6% for Enterococcus faecalis) for 1123 isolates from clinical samples of sputum, blood, urine, and feces. This strategy demonstrates that THz spectroscopy integrated with an automatic recognition method based on multi-classifier voting significantly improves the accuracy of spectral analysis, thereby presenting a new method for true label-free identification of clinical microorganisms with high efficiency.
- 31 May 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (6) , 378
Open AccessTHz-ATR Spectroscopy Integrated with Species Recognition Based on Multi-Classifier Voting for Automated Clinical Microbial Identification
The demand for rapid and accurate identification of microorganisms is growing due to considerable importance in all areas related to public health and safety. Here, we demonstrate a rapid and label-free strategy for the identification of microorganisms by integrating terahertz-attenuated total reflection (THz-ATR) spectroscopy with an automated recognition method based on multi-classifier voting. Our results show that 13 standard microbial strains can be classified into three different groups of microorganisms (Gram-positive bacteria, Gram-negative bacteria, and fungi) by THz-ATR spectroscopy. To detect clinical microbial strains with better differentiation that accounts for their greater sample heterogeneity, an automated recognition algorithm is proposed based on multi-classifier voting. It uses three types of machine learning classifiers to identify five different groups of clinical microbial strains. The results demonstrate that common microorganisms, once time-consuming to distinguish by traditional microbial identification methods, can be rapidly and accurately recognized using THz-ATR spectra in minutes. The proposed automatic recognition method is optimized by a spectroscopic feature selection algorithm designed to identify the optimal diagnostic indicator, and the combination of different machine learning classifiers with a voting scheme. The total diagnostic accuracy reaches 80.77% (as high as 99.6% for Enterococcus faecalis) for 1123 isolates from clinical samples of sputum, blood, urine, and feces. This strategy demonstrates that THz spectroscopy integrated with an automatic recognition method based on multi-classifier voting significantly improves the accuracy of spectral analysis, thereby presenting a new method for true label-free identification of clinical microorganisms with high efficiency.