Shaun T. Lancaster
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shaun T. Lancaster has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Johanna Irrgeher
Chair of General and Analytical Chemistry, Montanuniversität Leoben, Leoben, Austria
7 shared publications - Thomas Prohaska
Department of General, Analytical and Physical Chemistry, Chair of General and Analytical Chemistry, Montanuniversität Leoben, Leoben, Austria
6 shared publications - Anita Röthke
Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
2 shared publications - Axel Pramann
Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
2 shared publications - Ben Russell
Nuclear Metrology Group, National Physical Laboratory, Hampton Road, Teddington, UK
2 shared publications - Daniel Pröfrock
Institute of Coastal Environmental Chemistry, Helmholtz Zentrum Hereon, Geesthacht, Germany
2 shared publications
Latest Publications
- Open Access
- 17 January 2026
- Published by Springer Nature in Aquatic Sciences
- Vol. 88 (2) , 25
Spatio-temporal variations of strontium isotope ratios in the Mur River: a tool to support river management
This study explores the application of strontium (Sr) isotope ratios ( 87 Sr/ 86 Sr) as geochemical tracers to understand hydrological connectivity and anthropogenic influences in a geologically diverse Alpine river catchment encompassing regions of Austria and Slovenia. Focusing on the Mur River and its tributaries, water samples were collected across 45 sites during three hydrological regimes to capture seasonal and spatial variability. In total, 28 tributaries were sampled to evaluate their influence on the isotope composition of the main river. Isotope analyses using multi-collector inductively coupled plasma mass spectrometry, supplemented by geospatial mapping and multivariate statistics, were combined with measurements of 26 elemental concentrations to investigate land–water interactions and human impacts. The results demonstrate substantial temporal and spatial variability in 87 Sr/ 86 Sr ratios (ranging from 0.70853 to 0.71322), reflecting both geological heterogeneity and varying tributary inputs. A preliminary aquatic isoscape was developed, enabling the monitoring of connectivity and the impacts of geological and human influences under varying flow regimes. Tributaries, such as the Mürz River, significantly modulate isotope signatures in the main channel, often overriding local geological signals. The application of isotope pattern deconvolution revealed a contribution of 17% from the Mürz River to the Mur River’s isotope signature downstream of the confluence. Correlations between 87 Sr/ 86 Sr and metal concentrations further suggest the utility of 87 Sr/ 86 Sr as a proxy for source identification and anthropogenic influence assessment. By constructing a preliminary strontium isoscape for the region, this research provides novel insights into riverine connectivity, catchment-scale processes, and ecosystem dynamics. The integration of isotope data contributes to interdisciplinary understanding across geological, chemical, and ecological boundaries, and supports the development of isotope-based tools for sustainable aquatic system monitoring and management, including potential applications in fish ecology and habitat tracking. Graphical abstract
- 17 January 2026
- Published by Springer Nature in Aquatic Sciences
- Vol. 88 (2) , 25
Open AccessSpatio-temporal variations of strontium isotope ratios in the Mur River: a tool to support river management
This study explores the application of strontium (Sr) isotope ratios ( 87 Sr/ 86 Sr) as geochemical tracers to understand hydrological connectivity and anthropogenic influences in a geologically diverse Alpine river catchment encompassing regions of Austria and Slovenia. Focusing on the Mur River and its tributaries, water samples were collected across 45 sites during three hydrological regimes to capture seasonal and spatial variability. In total, 28 tributaries were sampled to evaluate their influence on the isotope composition of the main river. Isotope analyses using multi-collector inductively coupled plasma mass spectrometry, supplemented by geospatial mapping and multivariate statistics, were combined with measurements of 26 elemental concentrations to investigate land–water interactions and human impacts. The results demonstrate substantial temporal and spatial variability in 87 Sr/ 86 Sr ratios (ranging from 0.70853 to 0.71322), reflecting both geological heterogeneity and varying tributary inputs. A preliminary aquatic isoscape was developed, enabling the monitoring of connectivity and the impacts of geological and human influences under varying flow regimes. Tributaries, such as the Mürz River, significantly modulate isotope signatures in the main channel, often overriding local geological signals. The application of isotope pattern deconvolution revealed a contribution of 17% from the Mürz River to the Mur River’s isotope signature downstream of the confluence. Correlations between 87 Sr/ 86 Sr and metal concentrations further suggest the utility of 87 Sr/ 86 Sr as a proxy for source identification and anthropogenic influence assessment. By constructing a preliminary strontium isoscape for the region, this research provides novel insights into riverine connectivity, catchment-scale processes, and ecosystem dynamics. The integration of isotope data contributes to interdisciplinary understanding across geological, chemical, and ecological boundaries, and supports the development of isotope-based tools for sustainable aquatic system monitoring and management, including potential applications in fish ecology and habitat tracking. Graphical abstract
- 2 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 556-567
Investigating the potential of methyl fluoride cell gas for radionuclide interference removal and measurement using ICP-MS/MS
Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) has established itself as a valuable analytical technique for measurement of a range of medium- and long-lived radionuclides.
- 2 January 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (2) , 556-567
Investigating the potential of methyl fluoride cell gas for radionuclide interference removal and measurement using ICP-MS/MS
Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) has established itself as a valuable analytical technique for measurement of a range of medium- and long-lived radionuclides.
- Open Access
- 7 October 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3210-3220
Isobaric interference removal for selected radionuclides using nitrous oxide and ammonia with inductively coupled plasma tandem mass spectrometry
The determination of long-lived radionuclides by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is a well-established approach. However, such determinations can still be hindered by isobaric interferences from stable isotopes of neighbouring elements. As such, investigations towards novel gas cell approaches for removing interfering ions are required in order to improve the reliability of the analysis. Nitrous oxide (N2O) is a reaction gas that has been well studied for stable isotope analysis. Studies towards its applicability to radionuclide analysis have so far been limited. Here, the use of N2O, as well as a mixture with ammonia (NH3), have been evaluated for determinations of 10 radionuclides of interest for nuclear decommissioning: 41Ca, 63Ni, 79Se, 90Sr, 93Zr, 93Mo, 94Nb, 107Pd, 135Cs, and 137Cs. Single element solutions of stable isotope analogues of the radionuclides, as well as solutions of the interfering ions, were used to observe the reactions with the ICP-MS/MS reaction cell gases. Abundance-corrected sensitivities were used to assess the achievable separation factors and sensitivities for the determination of the radionuclides of interest. The N2O/NH3 gas mixture was found to provide a significant enhancement in the removal of isobaric interferences, as well as instrument detection limits (given in brackets), compared to N2O alone for determinations of 41Ca (0.50 pg g−1 (0.0016 Bq g−1)), 79Se (0.11 pg g−1 (5.4 × 10−5 Bq g−1)), 90Sr (0.11 pg g−1 (0.56 Bq g−1)), 93Mo (0.12 pg g−1 (0.0044 Bq g−1)), 135Cs (0.1 pg g−1 (7.5 × 10−6 Bq g−1)), and 137Cs (0.1 pg g−1 (0.33 Bq g−1)).
- 7 October 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3210-3220
Open AccessIsobaric interference removal for selected radionuclides using nitrous oxide and ammonia with inductively coupled plasma tandem mass spectrometry
The determination of long-lived radionuclides by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is a well-established approach. However, such determinations can still be hindered by isobaric interferences from stable isotopes of neighbouring elements. As such, investigations towards novel gas cell approaches for removing interfering ions are required in order to improve the reliability of the analysis. Nitrous oxide (N2O) is a reaction gas that has been well studied for stable isotope analysis. Studies towards its applicability to radionuclide analysis have so far been limited. Here, the use of N2O, as well as a mixture with ammonia (NH3), have been evaluated for determinations of 10 radionuclides of interest for nuclear decommissioning: 41Ca, 63Ni, 79Se, 90Sr, 93Zr, 93Mo, 94Nb, 107Pd, 135Cs, and 137Cs. Single element solutions of stable isotope analogues of the radionuclides, as well as solutions of the interfering ions, were used to observe the reactions with the ICP-MS/MS reaction cell gases. Abundance-corrected sensitivities were used to assess the achievable separation factors and sensitivities for the determination of the radionuclides of interest. The N2O/NH3 gas mixture was found to provide a significant enhancement in the removal of isobaric interferences, as well as instrument detection limits (given in brackets), compared to N2O alone for determinations of 41Ca (0.50 pg g−1 (0.0016 Bq g−1)), 79Se (0.11 pg g−1 (5.4 × 10−5 Bq g−1)), 90Sr (0.11 pg g−1 (0.56 Bq g−1)), 93Mo (0.12 pg g−1 (0.0044 Bq g−1)), 135Cs (0.1 pg g−1 (7.5 × 10−6 Bq g−1)), and 137Cs (0.1 pg g−1 (0.33 Bq g−1)).
- Open Access
- 16 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (38) , 20788-20797
δ(18O/16O) Determinations in Water Using Inductively Coupled Plasma–Tandem Mass Spectrometry
A fully validated measurement approach for the determination of oxygen isotope ratios in water using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described for the first time. Deuterium was used as a reaction gas to mass-shift the oxygen isotopes to the OD3+ product ion, allowing for the removal of polyatomic ions (16O1H+ and 16O1H2+) generated in the plasma that interfere on the less abundant oxygen stable isotopes (17O and 18O). The developed methodology was validated for δVSMOW-SLAP(18O/16O) determinations using four internationally recognized IAEA reference materials, as well as 11 in-house laboratory isotope reference materials that were characterized by isotope ratio mass spectrometry and cavity ring-down spectroscopy. δVSMOW-SLAP(18O/16O) values determined by ICP-MS/MS and the reference methods overlapped within the uncertainties and showed no significant difference for water materials with a low matrix load. Elevated levels of sodium, chloride, and silicon in the matrix lead to isotope ratio shifts of up to 12‰ in both the positive and negative directions. Additionally, comparisons with indicative values from the reference materials demonstrated that δVSMOW-SLAP(17O/16O) determinations are also possible using the ICP-MS/MS approach. While the uncertainty of the developed approach (median uncertainty uc(δVSMOW-SLAP(18O/16O)) = 0.70‰) is not currently able to match that of existing methodologies, it is envisioned that oxygen isotope ratio determinations can be performed alongside multielemental analysis by a wider community for applications where lower uncertainties are not required.
- 16 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (38) , 20788-20797
Open Accessδ(18O/16O) Determinations in Water Using Inductively Coupled Plasma–Tandem Mass Spectrometry
A fully validated measurement approach for the determination of oxygen isotope ratios in water using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described for the first time. Deuterium was used as a reaction gas to mass-shift the oxygen isotopes to the OD3+ product ion, allowing for the removal of polyatomic ions (16O1H+ and 16O1H2+) generated in the plasma that interfere on the less abundant oxygen stable isotopes (17O and 18O). The developed methodology was validated for δVSMOW-SLAP(18O/16O) determinations using four internationally recognized IAEA reference materials, as well as 11 in-house laboratory isotope reference materials that were characterized by isotope ratio mass spectrometry and cavity ring-down spectroscopy. δVSMOW-SLAP(18O/16O) values determined by ICP-MS/MS and the reference methods overlapped within the uncertainties and showed no significant difference for water materials with a low matrix load. Elevated levels of sodium, chloride, and silicon in the matrix lead to isotope ratio shifts of up to 12‰ in both the positive and negative directions. Additionally, comparisons with indicative values from the reference materials demonstrated that δVSMOW-SLAP(17O/16O) determinations are also possible using the ICP-MS/MS approach. While the uncertainty of the developed approach (median uncertainty uc(δVSMOW-SLAP(18O/16O)) = 0.70‰) is not currently able to match that of existing methodologies, it is envisioned that oxygen isotope ratio determinations can be performed alongside multielemental analysis by a wider community for applications where lower uncertainties are not required.
- Open Access
- 19 October 2024
- Published by Elsevier in Waste Management
- Vol. 190, 496-505
Evaluation of X-ray fluorescence for analysing critical elements in three electronic waste matrices: A comprehensive comparison of analytical techniques
- 19 October 2024
- Published by Elsevier in Waste Management
- Vol. 190, 496-505
Open AccessEvaluation of X-ray fluorescence for analysing critical elements in three electronic waste matrices: A comprehensive comparison of analytical techniques
- Open Access
- 18 September 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (11) , 2809-2823
Development and application of reference and routine analytical methods providing SI-traceable results for the determination of technology-critical elements in PCB from WEEE
The recovery and reprocessing of technology-critical elements (TCE) present in printed circuit boards (PCB) from electrical and electronic waste is essential both for recycling valuable materials subject to supply risk and for reducing the environmental impact. Although the quantitative knowledge of TCE amounts in end-of-life PCB plays a key role, there are neither matrix certified reference materials nor harmonized analytical methods available to establish the traceability of the results to the International System of Units. To fill these gaps, we developed and applied five reference analytical methods based on ICP-MS standard addition calibrations and INAA k0- and relative calibrations suitable to certify reference materials. In addition, we developed and tested six analytical methods based on more commonly used ICP-MS external standard calibrations to provide industry with routine analysis methods. Twenty TCE (Ag, Au, Co, Cu, Dy, Ga, Gd, Ge, In, La, Li, Nd, Ni, Pd, Pr, Pt, Rh, Sm, Ta and Ti) were selected as target analytes and a batch of powdered PCB was used as measurement material. An overall mutual agreement was observed among data collected by reference methods at a few percent relative uncertainty levels. Moreover, all but one of the methods developed for routine analysis demonstrated their suitability in industrial applications by producing data within ± 20% of the values established with reference methods.
- 18 September 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (11) , 2809-2823
Open AccessDevelopment and application of reference and routine analytical methods providing SI-traceable results for the determination of technology-critical elements in PCB from WEEE
The recovery and reprocessing of technology-critical elements (TCE) present in printed circuit boards (PCB) from electrical and electronic waste is essential both for recycling valuable materials subject to supply risk and for reducing the environmental impact. Although the quantitative knowledge of TCE amounts in end-of-life PCB plays a key role, there are neither matrix certified reference materials nor harmonized analytical methods available to establish the traceability of the results to the International System of Units. To fill these gaps, we developed and applied five reference analytical methods based on ICP-MS standard addition calibrations and INAA k0- and relative calibrations suitable to certify reference materials. In addition, we developed and tested six analytical methods based on more commonly used ICP-MS external standard calibrations to provide industry with routine analysis methods. Twenty TCE (Ag, Au, Co, Cu, Dy, Ga, Gd, Ge, In, La, Li, Nd, Ni, Pd, Pr, Pt, Rh, Sm, Ta and Ti) were selected as target analytes and a batch of powdered PCB was used as measurement material. An overall mutual agreement was observed among data collected by reference methods at a few percent relative uncertainty levels. Moreover, all but one of the methods developed for routine analysis demonstrated their suitability in industrial applications by producing data within ± 20% of the values established with reference methods.
- Open Access
- 11 October 2023
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 58 (4) , 288-300
Development of an online analyser to meet challenging new discharge limits for mercury in flue gas desulphurisation wastewater
Anthropogenic emissions of mercury to the environment are of great concern due to its toxicity. The burning of coal contributes highly to Hg emissions and, as such, much lower effluent discharge limits for Hg in flue gas desulphurisation (FGD) wastewater have recently been proposed in the USA. Lower detection limits are required to meet the most demanding discharge limit of 10 ng L−1. Therefore, in this work, a new analyser for online monitoring of Hg in FGD wastewater based on syringe injections of chemicals combined with gold amalgamation – atomic fluorescence spectrometry has been developed. The instrument has been validated against international standard method ISO 17852, as well as an interference study with extreme levels of salts majorly present in FGD water. Detection limits of 1.8 ng L−1 as well as accurate performance in an on-site field trial indicate that the methodology is fit to meet the new legislation.
- 11 October 2023
- Published by IWA Publishing in Water Quality Research Journal
- Vol. 58 (4) , 288-300
Open AccessDevelopment of an online analyser to meet challenging new discharge limits for mercury in flue gas desulphurisation wastewater
Anthropogenic emissions of mercury to the environment are of great concern due to its toxicity. The burning of coal contributes highly to Hg emissions and, as such, much lower effluent discharge limits for Hg in flue gas desulphurisation (FGD) wastewater have recently been proposed in the USA. Lower detection limits are required to meet the most demanding discharge limit of 10 ng L−1. Therefore, in this work, a new analyser for online monitoring of Hg in FGD wastewater based on syringe injections of chemicals combined with gold amalgamation – atomic fluorescence spectrometry has been developed. The instrument has been validated against international standard method ISO 17852, as well as an interference study with extreme levels of salts majorly present in FGD water. Detection limits of 1.8 ng L−1 as well as accurate performance in an on-site field trial indicate that the methodology is fit to meet the new legislation.
- Open Access
- 28 April 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (5) , 1135-1145
Characterisation of gas cell reactions for 70+ elements using N2O for ICP tandem mass spectrometry measurements
Gas cell interactions of 73 elements with nitrous oxide (N2O) have been evaluated using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). Recommendations for the reduction of interferences are provided.
- 28 April 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (5) , 1135-1145
Open AccessCharacterisation of gas cell reactions for 70+ elements using N2O for ICP tandem mass spectrometry measurements
Gas cell interactions of 73 elements with nitrous oxide (N2O) have been evaluated using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). Recommendations for the reduction of interferences are provided.
- Open Access
- 10 January 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (6) , 1159-1172
Determination of 48 elements in 7 plant CRMs by ICP-MS/MS with a focus on technology-critical elements
Seven plant certified reference materials (NIST SRM1515 Apple Leaves, NIST SRM1547 Peach Leaves, BCR-129 Hay Powder, BCR-670 Aquatic Plant, GBW07603 Bush Twigs and Leaves, GBW10015 Spinach Leaves and NCS ZC73036a Green Tea) were analysed for their mass fractions of 48 elements by inductively coupled plasma tandem-mass spectrometry (ICP-MS/MS): Li, Be, Na, Mg, Al, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Y, Nb, Mo, Ag, Cd, Sb, Te, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Ta, Tl, Pb, Bi, Th, U. Special focus was put on the determination of technology-critical elements (TCEs), to which, e.g. Li, Be, Ga, Ge, Nb, Sb, Ta, Tl, Bi, and the rare-earth elements (REEs, lanthanides and Y) are counted. Closed-vessel microwave digestion was performed using HNO3, H2O2 and HBF4. The average bias for certified values is − 1% ± 13% (SD). Limits of detection (xL) in the measured solutions lie between 13 fg g−1 (Tb) and 52 ng g−1 (Ca). This article seeks to provide an optimised measurement procedure for the determination of element mass fractions of emerging importance in environmental samples, which are challenging to analyse with more traditional techniques such as single-quad ICP-MS. In addition, it aims to improve the characterisation of commonly used plant reference materials by providing mass fraction data for rarely studied elements. Graphical abstract
- 10 January 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (6) , 1159-1172
Open AccessDetermination of 48 elements in 7 plant CRMs by ICP-MS/MS with a focus on technology-critical elements
Seven plant certified reference materials (NIST SRM1515 Apple Leaves, NIST SRM1547 Peach Leaves, BCR-129 Hay Powder, BCR-670 Aquatic Plant, GBW07603 Bush Twigs and Leaves, GBW10015 Spinach Leaves and NCS ZC73036a Green Tea) were analysed for their mass fractions of 48 elements by inductively coupled plasma tandem-mass spectrometry (ICP-MS/MS): Li, Be, Na, Mg, Al, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Y, Nb, Mo, Ag, Cd, Sb, Te, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Ta, Tl, Pb, Bi, Th, U. Special focus was put on the determination of technology-critical elements (TCEs), to which, e.g. Li, Be, Ga, Ge, Nb, Sb, Ta, Tl, Bi, and the rare-earth elements (REEs, lanthanides and Y) are counted. Closed-vessel microwave digestion was performed using HNO3, H2O2 and HBF4. The average bias for certified values is − 1% ± 13% (SD). Limits of detection (xL) in the measured solutions lie between 13 fg g−1 (Tb) and 52 ng g−1 (Ca). This article seeks to provide an optimised measurement procedure for the determination of element mass fractions of emerging importance in environmental samples, which are challenging to analyse with more traditional techniques such as single-quad ICP-MS. In addition, it aims to improve the characterisation of commonly used plant reference materials by providing mass fraction data for rarely studied elements. Graphical abstract
- Open Access
- 31 May 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (25) , 7495-7502
Low-level 40Ca determinations using nitrous oxide with reaction cell inductively coupled plasma–tandem mass spectrometry
In inductively coupled plasma mass spectrometry, the most abundant Ca isotope (40Ca) suffers from isobaric interference with argon, hindering the potential for low detection limits of Ca. A powerful approach is to remove the interference by using a reaction gas in a reaction cell. Ammonia (NH3) has proven to be an effective reaction gas by process of a charge transfer reaction. However, NH3 is highly corrosive and toxic and cannot remove isobaric 40 K. Therefore, this work proposes the use of nitrous oxide (N2O) to mass shift the target analyte 40Ca to 40Ca16O+ as a non-corrosive and non-toxic alternative. Instrument performance testing demonstrated that N2O was capable of reaching equivalent detection limits (0.015 ng g−1) and background equivalence concentrations (0.041 ng g−1) to that of NH3 and limited by the blank only. Further investigation of matrix interferences with synthetic standards highlighted that the N2O approach supports the separation of potassium (K) and magnesium (Mg)–based interferences at tested concentrations of more than 600 times and almost 800 times higher than Ca respectively, whereas NH3 was found to only support the removal of Mg. This work highlights a clear advantage of N2O for low-level Ca determinations with high matrix loads, as well as compatibility with other instrumentation sensitive to corrosion that supports reaction cell technology. Graphical abstract
- 31 May 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (25) , 7495-7502
Open AccessLow-level 40Ca determinations using nitrous oxide with reaction cell inductively coupled plasma–tandem mass spectrometry
In inductively coupled plasma mass spectrometry, the most abundant Ca isotope (40Ca) suffers from isobaric interference with argon, hindering the potential for low detection limits of Ca. A powerful approach is to remove the interference by using a reaction gas in a reaction cell. Ammonia (NH3) has proven to be an effective reaction gas by process of a charge transfer reaction. However, NH3 is highly corrosive and toxic and cannot remove isobaric 40 K. Therefore, this work proposes the use of nitrous oxide (N2O) to mass shift the target analyte 40Ca to 40Ca16O+ as a non-corrosive and non-toxic alternative. Instrument performance testing demonstrated that N2O was capable of reaching equivalent detection limits (0.015 ng g−1) and background equivalence concentrations (0.041 ng g−1) to that of NH3 and limited by the blank only. Further investigation of matrix interferences with synthetic standards highlighted that the N2O approach supports the separation of potassium (K) and magnesium (Mg)–based interferences at tested concentrations of more than 600 times and almost 800 times higher than Ca respectively, whereas NH3 was found to only support the removal of Mg. This work highlights a clear advantage of N2O for low-level Ca determinations with high matrix loads, as well as compatibility with other instrumentation sensitive to corrosion that supports reaction cell technology. Graphical abstract