Latest Publications

  • Open Access

    Finite Element Modeling for Biomechanical Comparisons of Multilevel Transforaminal, Posterior, and Lateral Lumbar Approaches to Interbody Fusion Augmented with Posterior Instrumentation

    by Yutaro Shimooki, Hideki Murakami, Norihiro Nishida, Hirotaka Yan, Ryo Oikawa, Endo Hirooki, Daisuke Yamabe, Yusuke Chiba, Takashi Sakai, Minoru Doita


  • Open Access

    Comparison of the Susceptibility to Implant Failure in the Lateral, Posterior, and Transforaminal Lumbar Interbody Fusion: A Finite Element Analysis

    by Ryo Oikawa, Hideki Murakami, Hirooki Endo, Hirotaka Yan, Daisuke Yamabe, Yusuke Chiba, Ryosuke Oikawa, Norihiro Nishida, Xian Chen, Takashi Sakai, et al.


  • Open Access

    Comparison of Hybrid Posterior Fixation and Conventional Open Posterior Fixation Combined with Multilevel Lateral Lumbar Interbody Fusion for Adult Spinal Deformity

    by Hirooki Endo, Hideki Murakami, Daisuke Yamabe, Yusuke Chiba, Ryosuke Oikawa, Hirotaka Yan, Minoru Doita

    We compared radiological and clinical outcomes between multilevel lateral lumbar interbody fusion (LLIF) + hybrid posterior fixation (PF) and multilevel LLIF + conventional open PF in patients with adult spinal deformity (ASD). Patients who underwent minimally invasive surgery for ASD in a single institution between 2014 and 2018 were retrospectively reviewed. Fifty-six patients (hybrid PF, 30; open PF, 26) who underwent ASD correction surgery were enrolled between 2014 and 2018. We evaluated patients’ demographics, clinical outcomes, and radiographical parameters in each group. There was significantly less estimated blood loss in the hybrid PF group (662.8 mL vs. 1088.8 mL; p = 0.012). The CRP level 7 days after surgery was significantly lower in the hybrid PF group (2.9 mg/dL vs. 4.3 mg/dL; p = 0.035). There was no significant difference between the two groups in other demographic variables, visual analog scores for back pain and leg pain, Oswestry Disability Index, coronal Cobb angle, lumbar lordosis, pelvic tilt, pelvic incidence–lumbar lordosis mismatch, and sagittal vertical axis. There was a significantly higher percentage of major complications in the open PF group (42.3% vs. 13.3%; p = 0.039). Thus, LLIF + hybrid PF for ASD corrective surgery may be comparable to LLIF + open PF in terms of clinical and radiographic outcomes.


  • Analysis of characteristics required for gait evaluation of patients with knee osteoarthritis using a wireless accelerometer

    by Shuntaro Wada, Hideki Murakami, Goro Tajima, Moritaka Maruyama, Atsushi Sugawara, Shinya Oikawa, Yasushi Chida, Minoru Doita


  • Open Access

    Quantification of metal‐induced susceptibility artifacts associated with ultrahigh‐field magnetic resonance imaging of spinal implants

    by Yusuke Chiba, Hideki Murakami, Makoto Sasaki, Hirooki Endo, Daisuke Yamabe, Daichi Kinno, Minoru Doita

    Reports on spinal‐implant metallic artifacts in 7‐T magnetic resonance imaging (MRI) are lacking. Thus, we investigated the magnitude of metal artifacts derived from spinal implants in 7‐T MRI and analyzed the differences obtained with spinal rods manufactured from pure titanium, titanium alloy, and cobalt‐chrome (5.5‐mm and 6.0‐mm diameters and 50‐mm length). Following the American Society for Testing and Materials guidelines, we measured the artifact size and artifact volume ratio of each rod during image acquisition using 7‐T MRI scanners with three‐dimensional (3D) T1‐weighted and 3D T2* spoiled gradient echo (GRE), 3D T2‐weighted fast spin echo, zero echo time (ZTE), and diffusion‐weighted imaging sequences. Pure titanium and titanium alloy rods yielded significantly smaller artifacts than did cobalt‐chrome rods, with no significant difference between pure titanium and titanium alloy rods. The artifact sizes of the 5.5‐mm and 6.0‐mm diameter rods were similar. The artifact magnitude increased in the following sequence order: ZTE, 3D T2 fast spin echo, 3D T1 spoiled GRE, 3D T2* spoiled GRE, and diffusion‐weighted imaging. Artifacts obtained using the spin echo method were smaller than those obtained with the GRE method. Because the echo time in ZTE is extremely short, the occurrence of artifacts because of image distortion and signal loss caused by differences in magnetic susceptibility is minimal, resulting in the smallest artifacts. ZTE can be a clinically useful method for the postoperative evaluation of patients after instrumentation surgery, even with 7‐T MRI.


  • Evaluation of the serum ionic fluoride concentration as a biomarker of bone metabolism post-spinal fusion surgery

    by Ryosuke Oikawa, Yuji Fujita, Hideki Murakami, Hirooki Endo, Daisuke Yamabe, Yusuke Chiba, Yuichiro Abe, Minoru Doita


  • Open Access

    Assessment of magnetic field interactions and radiofrequency-radiation-induced heating of metallic spinal implants in 7 T field

    by Itsuko Tsukimura, Hideki Murakami, Makoto Sasaki, Hirooki Endo, Daisuke Yamabe, Ryosuke Oikawa, Minoru Doita

    The safety of metallic spinal implants in magnetic resonance imaging (MRI) performed using ultrahigh fields has not been established. Hence, we examined whether the displacement forces caused by a static magnetic field and the heating induced by radiofrequency radiation are substantial for spinal implants in a 7 T field. We investigated spinal rods of various lengths and materials, a screw, and a cross-linking bridge in accordance with the American Society for Testing and Materials guidelines. The displacement forces of the metallic implants in static 7 T and 3 T static magnetic fields were measured and compared. The temperature changes of the implants during 15-min-long fast spin-echo and balanced gradient-echo image acquisition sequences were measured in the 7 T field. The deflection angles of the metallic spinal materials in the 7 T field were 5.0°–21.0° [median: 6.7°], significantly larger than those in the 3 T field (1.0°–6.3° [2.2°]). Among the metallic rods, the cobalt–chrome rods had significantly larger deflection angles (17.8°–21.0° [19.8°]) than the pure titanium and titanium alloy rods (5.0°–7.7° [6.2°]). The temperature changes of the implants, including the cross-linked rods, were 0.7°C–1.0°C [0.8°C] and 0.6°C–1.0°C [0.7°C] during the fast spin-echo and balanced gradient-echo sequences, respectively; these changes were slightly larger than those of the controls (0.4°C–1.1°C [0.5°C] and 0.3°C–0.9°C [0.6°C], respectively). All of the metallic spinal implants exhibited small displacement forces and minimal heating, indicating that MRI examinations using 7 T fields may be performed safely on patients with these implants. This article is protected by copyright. All rights reserved


  • A Biomechanical Study of 3 Different Types of Sublaminar Wire Used for Constructs in the Thoracic Spine

    by Hideki Murakami, Ken Yamazaki, Emad S. Attallah-Wasif, Kai-Jow Tsai, Tadashi Shimamura, William C. Hutton

    A biomechanical study was carried out on 3 different types of sublaminar wire used in constructs to secure the thoracic spine: stainless steel monofilament wire (steel wire), titanium cable (cable), and ultra-high molecular weight polyethylene tape (tape). Two experiments were carried out. Experiment 1: Thirty-one fresh human thoracic vertebrae classified as osteoporotic (bone mineral density of <0.8 g/cm2) were used. The steel wire, cable, or tape was placed sublaminarly and a tensile force was applied until the steel wire, cable, or tape cut 5 mm through the lamina, and the force at this point was noted. Experiment 2: Seven fresh human thoracic spines (T7–T10) were biomechanically tested as follows: axial compression (250 N), flexion (7.5 Nm), extension (7.5 Nm), left lateral bending (7.5 Nm), right lateral bending (7.5 Nm), left axial torsion (10 Nm), and right axial torsion (10 Nm). This sequence was applied to the intact spine. The spine was then de-stabilized and then restabilized using one or other of the 3 different types of sublaminar wires. The biomechanical testing was then repeated on the restabilized spine and stiffness curves were generated. In the laminar cut-through test, the cut-through force for tape was higher than that for either steel wire or cable. In the biomechanical stiffness testing, there was no significant difference between the 3 different sublaminar wiring constructs in any of the loading modes tested. The results of both experiments suggest that tape is as good, if not better, than steel wire or cable as a sublaminar wiring construct material.


  • A Biomechanical Assessment of Infra-Laminar Hooks as an Alternative to Supra-Laminar Hooks in Thoracolumbar Fixation

    by Hideki Murakami, Kai-Jow Tsai, Emad S. Attallah-Wasif, Ken Yamazaki, Tadashi Shimamura, William C. Dsc Hutton

    Study Design. Biomechanical study, using human cadaveric spines, of two types of posterior fixation in the thoracolumbar spine. Objectives. To compare fixation in the thoracolumbar spine using pedicle screws combined with infra-laminar hooks (at both the cranial and caudal ends of the same vertebra) with fixation using pedicle screws alone. Summary of Background Data. The standard method of using laminar hooks is to place supra-laminar hooks at the level above the vertebra being fixed by the cranial pedicle screws, and infra-laminar hooks at the level of the vertebra receiving the caudal pedicle screws. However, using this method, a single normal motion segment is killed. In the proposed technique, infra-laminar hooks will be used at the same level as the cranial pedicle screws, thus sparing the superior adjacent segment. Methods. Pedicle screw loosening test. Nine vertebrae (T9–L2) had pedicle screws inserted into both pedicles. On one side, the pedicle screw was connected to a fixation rod, while on the other side the pedicle screw was combined with an infra-laminar hook and connected to a rod. The rod on one side was then pushed with increasing force until loosening of the screw. The same test was repeated on the other rod until loosening of the screw. The reverse test (i.e., pulling until loosening) was done in a similar manner on another nine vertebrae. Biomechanical stiffness test. Eight spines (T12–L2) were biomechanically tested in: axial compression, flexion, extension, left and right lateral bending, and left and right axial torsion. This sequence was applied to: 1) the intact spine; 2) after applying pedicle screws and infra-laminar hooks with rods to the destabilized spine; and 3) after removal of the hooks (with the pedicle screw and rods still inserted). From the load-deformation curves obtained, stiffness values were calculated. Results. Pedicle screw loosening test. The pedicle screw loosening tests showed that a pedicle screw combined with an infra-laminar hook offers significantly greater fixation strength as compared to a pedicle screw alone. Biomechanical stiffness test. Fixation by pedicle screws combined with infra-laminar hooks, placed on the vertebra fixed by pedicle screws at both the cranial and caudal ends, offered a stiffer construct as compared to fixation by pedicle screws alone. Conclusions. This method offers a firm construct without sacrificing a normal motion segment.