RSRostislav A. Stavinskiy

Rostislav A. Stavinskiy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rostislav A. Stavinskiy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Features of the synthesis of reduced state monitoring devices for dc electric actuators with modal control

    by O.S. Sadovoy, A.A. Stavynskyy, A.YU. Rudenko, R.A. Stavynskyy, A.P. Gurov, O.G. Vasiliev

    Purpose. The purpose of the study is the development and justification of a methodology for the synthesis of reduced state monitoring devices for DC electric drives with modal control, as well as the analysis of their impact on the dynamic properties, stability and quality indicators of transient processes of electromechanical systems. Methodology. The work uses methods of automatic control theory and state space theory, in particular methods of modal synthesis and pole placement. To build a reduced observation device, analytical methods of linear algebra and matrix analysis were used. The study of the dynamic properties of the electromechanical system was performed using methods of mathematical modeling and simulation experiment in the MATLAB software environment. The quality of transient processes was assessed based on the analysis of time characteristics and stability indicators of the control system. Findings. Mathematical models of full and reduced state observation devices in the state space are developed and an algorithm for synthesis of a reduced observer is proposed, which provides recovery of only unmeasured state variables of the electric drive. It is shown that the choice of the speed of the reduced observation device, which exceeds the speed of the control object, guarantees the convergence of estimates and the correct operation of the modal control system. Using the example of second- and fourth-order electric drives, the possibility of recovering the integral component of the PI controller and the load moment without using additional sensors is proven. The simulation results show that in low-order systems, the use of a reduced observer can lead to a slight increase in overshoot and the duration of transients, while in higher-order systems its impact on dynamic indicators is minimal. Originality. The paper first substantiates the use of typical normalized equations of modular optimum for the synthesis of reduced observation devices in DC electric drive systems with modal control, and also establishes the dependence of the influence of a reduced observer on the dynamics of the system on its order. Practical value. The results obtained can be used in the design of control systems for electric drives with limited sensor capabilities, allowing to reduce the structural and hardware complexity of the system, increase its reliability, and simplify practical implementation without significantly degrading control quality indicators.

  • Open Access

    Improving the main indicators of transformers with twisted one-piece magnetic cores by changing the technology of circular winding turns formation

    by O. А. Avdieieva, L. V. Vakhonina, O. S. Sadovoy, R. A. Stavinskiy, O. M. Tsyganov

    Introduction. With the adoption of standards to reduce losses in transformers it is necessary to change the design of transformers that remain unchanged. Further energy saving is possible with the use of non-traditional technical solutions for the improvement of transformers. Problem. In order to reduce idle losses, the curved magnetic circuits of power transformers are carried out in the form of low-volume circuits. Windings are injected into assembled magnetic conductors by shuttle machines. The shuttle of windings provides technological gaps in winding windows, which results in an increase in size, metal capacity and losses. Goal. Rationale for transformer performance improvement by excluding process gaps in winding windows. Methodology. The definition of the change in transformer indicators is performed using optimization functions of the dimensionless indicators of the technological level. The adequacy of the functions is confirmed by the calculation of the mass of the electromagnetic system and the losses of the transformer. The figures of the compact analogue are calculated from the named serial analogue. Results. The result is a reduction in mass and a loss in the compactness of the transformer. Originality. The improvement of the indicators and the simplification of the winding technology are provided by a change in the design of insulating frames of winding coils. Winding on the rods is ensured by rotating the outer part of the composite insulating frame. Practical significance. Replacement the design of the windings of transformer with power of 40 kVA of 1000 V voltage class with a spatially twisted, small-dimensional magnetic conductor on a compact analogue leads to a reduction in mass and overall dimensions by 15 % and (17-18) %. Efficiency increases by 0.3 %.