Danial Soleymani-Ghoozhdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Danial Soleymani-Ghoozhdi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ali Firoozichahak
Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Sciences, Gonabad, Iran
5 shared publicationsRazzagh Rahimpoor
5 shared publications- Ali Firoozichahak
Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science, Gonabad, Iran
3 shared publications Saber Alizadeh
3 shared publications- Saber Alizadeh
Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
3 shared publications Somayeh Rahimimoghadam
Neyshabur University of Medical Sciences
3 shared publications
Latest Publications
- 30 June 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1420
Determination of BTEX in air samples using a needle trap device packed with a Zeolite@MOF composite adsorbent
- 30 June 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1420
Determination of BTEX in air samples using a needle trap device packed with a Zeolite@MOF composite adsorbent
- 12 November 2025
- Published by SAGE Publications in Toxicology and Industrial Health
- Vol. 41 (12) , 543-549
Health risk assessment of occupational exposure to hydrogen peroxide (H 2 O 2 ) among dairy processing plant workers
Hydrogen peroxide (H 2 O 2 ) is a well-known irritant that affects the eyes, respiratory tract, and skin, and long-term exposure may lead to chronic respiratory conditions such as bronchitis, pulmonary fibrosis, and an increased risk of lung cancer, particularly in occupational settings. The objective of this study was to evaluate occupational exposure to H 2 O 2 among dairy processing plant workers and to characterize the associated semi-quantitative risks using the methodology of the Singapore Occupational Health Department. This research was conducted in the sterilization units of three dairy processing plants located in Neyshabur, Iran. The semi-quantitative risk assessment in this study adhered to the methodology recommended by the Singapore Occupational Health Department. The findings revealed that the average occupational exposure to H 2 O 2 for 29 workers across three dairy processing plants was 0.91 ± 0.54 ppm, with individual exposure levels ranging from 0.10 to 2.12 ppm. The mean exposure level exceeded the adjusted threshold limit value (TLV) for H 2 O 2 (0.78 ppm). The evaluation of health risks associated with H 2 O 2 exposure revealed that all participants fell within the medium-risk category. This classification underscores the potential for adverse health effects among dairy workers and highlights the need for targeted interventions to mitigate exposure risks and enhance workplace safety.
- 12 November 2025
- Published by SAGE Publications in Toxicology and Industrial Health
- Vol. 41 (12) , 543-549
Health risk assessment of occupational exposure to hydrogen peroxide (H 2 O 2 ) among dairy processing plant workers
Hydrogen peroxide (H 2 O 2 ) is a well-known irritant that affects the eyes, respiratory tract, and skin, and long-term exposure may lead to chronic respiratory conditions such as bronchitis, pulmonary fibrosis, and an increased risk of lung cancer, particularly in occupational settings. The objective of this study was to evaluate occupational exposure to H 2 O 2 among dairy processing plant workers and to characterize the associated semi-quantitative risks using the methodology of the Singapore Occupational Health Department. This research was conducted in the sterilization units of three dairy processing plants located in Neyshabur, Iran. The semi-quantitative risk assessment in this study adhered to the methodology recommended by the Singapore Occupational Health Department. The findings revealed that the average occupational exposure to H 2 O 2 for 29 workers across three dairy processing plants was 0.91 ± 0.54 ppm, with individual exposure levels ranging from 0.10 to 2.12 ppm. The mean exposure level exceeded the adjusted threshold limit value (TLV) for H 2 O 2 (0.78 ppm). The evaluation of health risks associated with H 2 O 2 exposure revealed that all participants fell within the medium-risk category. This classification underscores the potential for adverse health effects among dairy workers and highlights the need for targeted interventions to mitigate exposure risks and enhance workplace safety.
- 25 March 2025
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 35 (11) , 3296-3308
Health risk assessment of occupational exposure to heavy metals among workers in the iron and steel industry
Heavy metals (HMs) emitted into the atmosphere from various sources pose numerous health risks, including cancer, respiratory and skin disorders, and neurological effects. This research aimed to conduct comprehensive quantitative and semi-quantitative risk assessments concerning HMs exposure among employees within the Iron and Steel industry. The study included a group of 149 workers exposed to HMs. Air sampling and analysis were conducted according to the NIOSH 7300 method. The semi-quantitative risk assessment followed the delineations provided by the Singapore Health Department, while the quantitative assessment adhered to the methodology outlined by the Office of Environmental Health Hazard Assessment. The study outcomes delineated those levels of exposure to heavy metals across all operational units were lower than the air exposure limits recommended by the ACGIH. According to the semi-quantitative risk assessment, a majority of workers were categorized within the negligible-risk level. Furthermore, mean carcinogenic risk values attributed to Cr surpassed the acceptable threshold of 1 × 10-4. The research findings also indicate the presence of non-carcinogenic risks associated with Mn and Cr exposure among the workforce. Thus, it is imperative to institute strategies aimed at mitigating workers' exposure to HMs, including the implementation of engineering controls and the establishment of regular monitoring protocols.
- 25 March 2025
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 35 (11) , 3296-3308
Health risk assessment of occupational exposure to heavy metals among workers in the iron and steel industry
Heavy metals (HMs) emitted into the atmosphere from various sources pose numerous health risks, including cancer, respiratory and skin disorders, and neurological effects. This research aimed to conduct comprehensive quantitative and semi-quantitative risk assessments concerning HMs exposure among employees within the Iron and Steel industry. The study included a group of 149 workers exposed to HMs. Air sampling and analysis were conducted according to the NIOSH 7300 method. The semi-quantitative risk assessment followed the delineations provided by the Singapore Health Department, while the quantitative assessment adhered to the methodology outlined by the Office of Environmental Health Hazard Assessment. The study outcomes delineated those levels of exposure to heavy metals across all operational units were lower than the air exposure limits recommended by the ACGIH. According to the semi-quantitative risk assessment, a majority of workers were categorized within the negligible-risk level. Furthermore, mean carcinogenic risk values attributed to Cr surpassed the acceptable threshold of 1 × 10-4. The research findings also indicate the presence of non-carcinogenic risks associated with Mn and Cr exposure among the workforce. Thus, it is imperative to institute strategies aimed at mitigating workers' exposure to HMs, including the implementation of engineering controls and the establishment of regular monitoring protocols.
- 7 November 2024
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 181
Microextraction by packed sorbents (MEPS): Fundamental principles and nanomaterial-based adsorbents
- 7 November 2024
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 181
Microextraction by packed sorbents (MEPS): Fundamental principles and nanomaterial-based adsorbents
- Open Access
- 9 June 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (26) , 17656-17666
Investigation of organophosphorus (OPs) compounds by a needle trap device based on mesoporous organo-layered double hydroxide (organo-LDH)
Organophosphorus (OPs) compounds can endanger human health and the environment by inhibiting the acetylcholinesterase enzyme. But these compounds have been widely used as pesticides due to their effectiveness against all kinds of pests. In this study, a Needle Trap Device (NTD) packed with mesoporous organo-layered double hydroxide (organo-LDH) material and coupled with gas chromatography-mass spectrometry (GC-MS) was employed for the sampling and analysis of OPs compounds (diazinon, ethion, malathion, parathion, and fenitrothion). In this way, the [magnesium–zinc–aluminum] layered double hydroxide ([Mg–Zn–Al] LDH) modified with sodium dodecyl sulfate (SDS) as a surfactant was prepared and characterized by FT-IR, XRD, BET, and FE-SEM, EDS, and elemental mapping techniques. Then, various parameters such as relative humidity, sampling temperature, desorption time, and desorption temperature were evaluated by the mesoporous organo-LDH:NTD method. The optimal values of these parameters were determined using response surface methodology (RMS) and central composite design (CCD). The optimal temperature and relative humidity values were obtained as 20 °C and 25.0%, respectively. On the other hand, the desorption temperature and time values were in the range of 245.0–254.0 °C and 5 min, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were reported in the range of 0.02–0.05 mg m−3 and 0.09–0.18 mg m−3, respectively, which shows the high sensitivity of the proposed method compared to the usual methods. The repeatability and reproducibility of the proposed method (by calculating the relative standard deviation) was estimated in the range of 3.8–10.10 which indicates the acceptable precision of the organo-LDH:NTD method. Also, the desorption rate of the stored needles at 25 °C and 4 °C, was determined to be 86.0% and 96.0%, respectively after 6 days. The results of this study proved that the mesoporous organo-LDH:NTD method can be utilized as a fast, simple, environmentally friendly, and effective method for sampling and determining OPs compounds in the air.
- 9 June 2023
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 13 (26) , 17656-17666
Open AccessInvestigation of organophosphorus (OPs) compounds by a needle trap device based on mesoporous organo-layered double hydroxide (organo-LDH)
Organophosphorus (OPs) compounds can endanger human health and the environment by inhibiting the acetylcholinesterase enzyme. But these compounds have been widely used as pesticides due to their effectiveness against all kinds of pests. In this study, a Needle Trap Device (NTD) packed with mesoporous organo-layered double hydroxide (organo-LDH) material and coupled with gas chromatography-mass spectrometry (GC-MS) was employed for the sampling and analysis of OPs compounds (diazinon, ethion, malathion, parathion, and fenitrothion). In this way, the [magnesium–zinc–aluminum] layered double hydroxide ([Mg–Zn–Al] LDH) modified with sodium dodecyl sulfate (SDS) as a surfactant was prepared and characterized by FT-IR, XRD, BET, and FE-SEM, EDS, and elemental mapping techniques. Then, various parameters such as relative humidity, sampling temperature, desorption time, and desorption temperature were evaluated by the mesoporous organo-LDH:NTD method. The optimal values of these parameters were determined using response surface methodology (RMS) and central composite design (CCD). The optimal temperature and relative humidity values were obtained as 20 °C and 25.0%, respectively. On the other hand, the desorption temperature and time values were in the range of 245.0–254.0 °C and 5 min, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were reported in the range of 0.02–0.05 mg m−3 and 0.09–0.18 mg m−3, respectively, which shows the high sensitivity of the proposed method compared to the usual methods. The repeatability and reproducibility of the proposed method (by calculating the relative standard deviation) was estimated in the range of 3.8–10.10 which indicates the acceptable precision of the organo-LDH:NTD method. Also, the desorption rate of the stored needles at 25 °C and 4 °C, was determined to be 86.0% and 96.0%, respectively after 6 days. The results of this study proved that the mesoporous organo-LDH:NTD method can be utilized as a fast, simple, environmentally friendly, and effective method for sampling and determining OPs compounds in the air.
- Open Access
- 23 May 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (25) , 16267-16276
Application of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide
In this research, a novel, selective, and efficient porous adsorbent nano-composite comprising a molecularly imprinted polymer and a metal–organic framework (MIP@MOF) was employed for sampling, extraction and analysis of diazinon from the air by a needle trap device (NTD), for the first time. The synthesized MIP@MOF sorbent was characterized by the FT-IR, XRD, FE-SEM, TEM, and EDS techniques. Then, the effective parameters of the sampling (temperature and humidity) and desorption (time and temperature) process were optimized by response surface methodology (RSM). The optimum values of temperature and humidity of the sampling chamber were estimated to be 20 °C and 25.0%, respectively. Also, the highest response during the analyte desorption was obtained at 262 °C and 4.5 minutes. For more details, the performance of the MIP@MOF:NTD method was evaluated by determination of important parameters such as repeatability, reproducibility, the limit of detection (LOD), and the limit of quantification (LOQ), and then compared with the NIOSH 5600 standard method. The values of LOD and LOQ for the targeted analyte were determined to be 0.02 and 0.1 μg m−3, respectively. Also, the repeatability and reproducibility of the proposed method were obtained in the range of (3.9–5.1)% and (5.1–6.4)%, respectively, which proved the acceptable precision of the method. Furthermore, the results of this study exhibited a high correlation coefficient (R2 = 0.9781) between the proposed method and the recommended NIOSH method. Finally, the proposed procedure was utilized for sampling and determination of the airborne diazinon in real conditions. These results indicated that the proposed MIP@MOF:NTD method can be employed as a fast, simple, environmentally friendly, selective, and effective procedure for sampling and determining diazinon in air.
- 23 May 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (25) , 16267-16276
Open AccessApplication of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide
In this research, a novel, selective, and efficient porous adsorbent nano-composite comprising a molecularly imprinted polymer and a metal–organic framework (MIP@MOF) was employed for sampling, extraction and analysis of diazinon from the air by a needle trap device (NTD), for the first time. The synthesized MIP@MOF sorbent was characterized by the FT-IR, XRD, FE-SEM, TEM, and EDS techniques. Then, the effective parameters of the sampling (temperature and humidity) and desorption (time and temperature) process were optimized by response surface methodology (RSM). The optimum values of temperature and humidity of the sampling chamber were estimated to be 20 °C and 25.0%, respectively. Also, the highest response during the analyte desorption was obtained at 262 °C and 4.5 minutes. For more details, the performance of the MIP@MOF:NTD method was evaluated by determination of important parameters such as repeatability, reproducibility, the limit of detection (LOD), and the limit of quantification (LOQ), and then compared with the NIOSH 5600 standard method. The values of LOD and LOQ for the targeted analyte were determined to be 0.02 and 0.1 μg m−3, respectively. Also, the repeatability and reproducibility of the proposed method were obtained in the range of (3.9–5.1)% and (5.1–6.4)%, respectively, which proved the acceptable precision of the method. Furthermore, the results of this study exhibited a high correlation coefficient (R2 = 0.9781) between the proposed method and the recommended NIOSH method. Finally, the proposed procedure was utilized for sampling and determination of the airborne diazinon in real conditions. These results indicated that the proposed MIP@MOF:NTD method can be employed as a fast, simple, environmentally friendly, selective, and effective procedure for sampling and determining diazinon in air.