Chen-Yu Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chen-Yu Pan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Hsieh-Chih Hsu
Intelligent System Laboratory, Department of Electrical Engineering, College of Electrical Engineering and Computer Science, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
7 shared publications - Chien-Chih Chen
Department of Information Management, National Chin-Yi University of Technology, Taichung 411030, Taiwan
2 shared publications Chin-Wei Chang
2 shared publicationsHsieh-Chih Hsu
2 shared publicationsI-Cheng Wu
2 shared publications- Ko-Wei Huang
National Kaohsiung University of Science and Technology
2 shared publications
Latest Publications
- 1 May 2026
- Published by Springer Nature
- p. 374-383
Evaluation of System Improvement Through Frequency Optimization of Fan Coil Systems Using ANOVA and the TOPSIS Method
- 1 May 2026
- Published by Springer Nature
- p. 374-383
Evaluation of System Improvement Through Frequency Optimization of Fan Coil Systems Using ANOVA and the TOPSIS Method
- Open Access
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Adaptive Screening Stations: Transforming 20‐Foot Shipping Containers for Contamination Control and Diverse Medical Needs
In the 21st century, the world has faced two major coronavirus threats. However, the severe acute respiratory syndrome (SARS) outbreak did not lead to sufficient reflection, resulting in the coronavirus disease 2019 (COVID‐19) pandemic surpassing SARS in scale. Many countries struggled to keep up with the rapid spread of the virus, leading to shortages of medical supplies and immense pressure on frontline healthcare workers, further highlighting the importance of medical resource classification. This study explores the adaptation of 20‐foot shipping containers into frontline screening stations to effectively separate existing medical resources. It considers national standards for pressure differentials and air change per hour (ACH) in medical spaces (noting that specific regulations for screening stations are currently lacking) and analyzes key environmental factors affecting indoor conditions, including temperature, humidity, carbon dioxide concentration, and power consumption. The results indicate that maintaining an ACH of 10 times (10 h −1 ) and a pressure differential of 2.5 Pa (positive or negative pressure), along with good airtightness, can effectively sustain indoor environmental quality in screening stations. Additionally, incorporating external ventilation fans enhances the adaptability of these stations, ensuring their usability both during and beyond pandemic periods.
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Open AccessAdaptive Screening Stations: Transforming 20‐Foot Shipping Containers for Contamination Control and Diverse Medical Needs
In the 21st century, the world has faced two major coronavirus threats. However, the severe acute respiratory syndrome (SARS) outbreak did not lead to sufficient reflection, resulting in the coronavirus disease 2019 (COVID‐19) pandemic surpassing SARS in scale. Many countries struggled to keep up with the rapid spread of the virus, leading to shortages of medical supplies and immense pressure on frontline healthcare workers, further highlighting the importance of medical resource classification. This study explores the adaptation of 20‐foot shipping containers into frontline screening stations to effectively separate existing medical resources. It considers national standards for pressure differentials and air change per hour (ACH) in medical spaces (noting that specific regulations for screening stations are currently lacking) and analyzes key environmental factors affecting indoor conditions, including temperature, humidity, carbon dioxide concentration, and power consumption. The results indicate that maintaining an ACH of 10 times (10 h −1 ) and a pressure differential of 2.5 Pa (positive or negative pressure), along with good airtightness, can effectively sustain indoor environmental quality in screening stations. Additionally, incorporating external ventilation fans enhances the adaptability of these stations, ensuring their usability both during and beyond pandemic periods.
- Open Access
- 24 July 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 1273-1282
Mixed-mode ventilation for indoor health and energy efficiency in subtropical climates
- 24 July 2025
- Published by Elsevier in Energy Reports
- Vol. 14, 1273-1282
Open AccessMixed-mode ventilation for indoor health and energy efficiency in subtropical climates
- 4 January 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 83
Air change per hour improvement for positive and negative pressure mechanical ventilation facilities systems
- 4 January 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 83
Air change per hour improvement for positive and negative pressure mechanical ventilation facilities systems
- Open Access
- 1 January 2024
- Published by Wiley in Indoor Air
- Vol. 2024 (1)
Natural Ventilation: Optimizing Window Opening Size for CO2 Concentration Control and Thermal Comfort on Nonwindward Facades
Natural ventilation has become a focal point due to its positive impact on indoor air quality, expanding its role in addressing thermal comfort issues in schools. Despite previous studies exploring various approaches to enhance natural ventilation, factors such as classrooms facing non‐windward directions and optimal window opening sizes have not been adequately considered. This lack of consideration poses challenges for implementation in school environments. To address this issue, this study employed response surface methodology, back‐propagation neural network, and multiple linear regression to investigate the effects of different factors on natural ventilation. Experiments were conducted in classrooms facing nonwindward directions, measuring indoor air changes per hour (ACH) during peak noon temperatures. Thermal comfort was assessed using the predicted mean vote (PMV). The experimental results showed that single window openings provided better thermal comfort compared to cross window openings while maintaining indoor CO2 concentrations below 1000 ppm. Furthermore, subsequent analysis revealed that the opening size (open and open/gap) increases the range of ACH, suggesting avenues for future research to enhance natural ventilation practices. This underscores natural ventilation’s potential in maintaining indoor thermal comfort and CO2 levels under challenging conditions.
- 1 January 2024
- Published by Wiley in Indoor Air
- Vol. 2024 (1)
Open AccessNatural Ventilation: Optimizing Window Opening Size for CO2 Concentration Control and Thermal Comfort on Nonwindward Facades
Natural ventilation has become a focal point due to its positive impact on indoor air quality, expanding its role in addressing thermal comfort issues in schools. Despite previous studies exploring various approaches to enhance natural ventilation, factors such as classrooms facing non‐windward directions and optimal window opening sizes have not been adequately considered. This lack of consideration poses challenges for implementation in school environments. To address this issue, this study employed response surface methodology, back‐propagation neural network, and multiple linear regression to investigate the effects of different factors on natural ventilation. Experiments were conducted in classrooms facing nonwindward directions, measuring indoor air changes per hour (ACH) during peak noon temperatures. Thermal comfort was assessed using the predicted mean vote (PMV). The experimental results showed that single window openings provided better thermal comfort compared to cross window openings while maintaining indoor CO2 concentrations below 1000 ppm. Furthermore, subsequent analysis revealed that the opening size (open and open/gap) increases the range of ACH, suggesting avenues for future research to enhance natural ventilation practices. This underscores natural ventilation’s potential in maintaining indoor thermal comfort and CO2 levels under challenging conditions.
- Open Access
- 8 August 2023
- Published by Hindawi Limited in Indoor Air
- Vol. 2023, 1-11
Application of Data-Driven Building Information Modeling in the Visual Simulation of Disease Transmission and Route with Pipeline System
Currently, preventing epidemics is an extremely critical global topic. Using present data to quickly conduct virus simulations is a difficult but interesting problem, especially when real situations are difficult to experimentally demonstrate. In the past, most studies have used package software for disease transmission simulation, but this approach is limited by availability and software cost. Therefore, we propose a visual simulation of disease transmission using building information modeling data and a 3D model using Unity. The results show that the proposed method can effectively predict the probability and route of disease transmission; it also verifies that the vertical pipeline on the floor plane is conducive to the spread of the virus (90%), and disease transmission on the plane gradually expands outward from the starting room and has a higher probability of spreading (80%) from the opposite room. In addition, a vertical pipeline was simulated using a toilet exhaust air ventilation pipeline, from which it can be observed that the adjacent floors have a higher diffusion probability (70%). It has also been confirmed that distance is the primary factor affecting disease transmission. This framework may provide designers and managers further protection against the spread of future epidemics.
- 8 August 2023
- Published by Hindawi Limited in Indoor Air
- Vol. 2023, 1-11
Open AccessApplication of Data-Driven Building Information Modeling in the Visual Simulation of Disease Transmission and Route with Pipeline System
Currently, preventing epidemics is an extremely critical global topic. Using present data to quickly conduct virus simulations is a difficult but interesting problem, especially when real situations are difficult to experimentally demonstrate. In the past, most studies have used package software for disease transmission simulation, but this approach is limited by availability and software cost. Therefore, we propose a visual simulation of disease transmission using building information modeling data and a 3D model using Unity. The results show that the proposed method can effectively predict the probability and route of disease transmission; it also verifies that the vertical pipeline on the floor plane is conducive to the spread of the virus (90%), and disease transmission on the plane gradually expands outward from the starting room and has a higher probability of spreading (80%) from the opposite room. In addition, a vertical pipeline was simulated using a toilet exhaust air ventilation pipeline, from which it can be observed that the adjacent floors have a higher diffusion probability (70%). It has also been confirmed that distance is the primary factor affecting disease transmission. This framework may provide designers and managers further protection against the spread of future epidemics.
- 31 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 66, 105817
Using the big data analysis and basic information from lecture Halls to predict air change rate
- 31 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 66, 105817
Using the big data analysis and basic information from lecture Halls to predict air change rate
- 20 May 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 54
Controlling the initiating time of ventilation facilities by spatial analytic method
- 20 May 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 54
Controlling the initiating time of ventilation facilities by spatial analytic method