QSQi Shao

Qi Shao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qi Shao has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Silent, Low-Heat Pinch Valve Driven by a Single Rolled Dielectric Elastomer Actuator

    by Qi Shao, Xin-Jun Liu, Fumiya Iida, Huichan Zhao

    Fluidic control for untethered soft robots is currently limited by the noise and bulk of solenoid valves. While dielectric elastomer actuators (DEAs) offer a promising soft alternative, existing designs often rely on high-frequency resonance, which induces mechanical vibration, or complex multiactuator stacking to generate sufficient force. Here, we present a miniature (5.0 g) pinch valve driven by a single rolled DEA operating in a nonresonant mode, simplifying the structural and driving system requirements. Our direct-drive design achieves measured sound levels close to the background noise level ($\sim 49 \text{ dB}$) and low heat generation ($5^{\circ }$C rise) while maintaining a rapid response time ($\sim 20 \text{ ms}$). We further integrate the valve into an untethered pneumatic multilegged robot, demonstrating reliable fluidic control at a locomotion speed of 77.5 cm/min.

  • EquiMus: Energy-Equivalent Dynamic Modeling and Simulation of Musculoskeletal Robots Driven by Linear Elastic Actuators

    by Yinglei Zhu, Xuguang Dong, Qiyao Wang, Qi Shao, Fugui Xie, Xinjun Liu, Huichan Zhao

    Dynamic modeling and control are critical for unleashing soft robots’ potential, yet remain challenging due to their complex constitutive behaviors and real-world operating conditions. Bio-inspired musculoskeletal robots, which integrate rigid skeletons with soft actuators, combine high load-bearing capacity with inherent flexibility. Although actuation dynamics have been studied through experimental methods and surrogate models, accurate and effective modeling and simulation remain a significant challenge, especially for large-scale hybrid rigid–soft robots with continuously distributed mass, kinematic loops, and diverse motion modes. To address these challenges, we propose EquiMus, an energy-equivalent dynamic modeling framework and MuJoCo-based simulation for musculoskeletal rigid–soft hybrid robots with linear elastic actuators. The equivalence and effectiveness of the proposed approach are validated and examined through both simulations and real-world experiments on a bionic robotic leg. EquiMus further demonstrates its utility for downstream tasks, including controller design and learning-based control strategies.

  • Long, Fibrous, and Tailorable Dielectric Elastomer Artificial Muscles via Mask‐Free Stamping of Carbon Nanotube Electrodes

    by Qi Shao, Liang Zhou, Jingyi Zhou, Xin‐Jun Liu, Huichan Zhao

    High‐performance, large‐size artificial muscles are in great demand in the field of robotics. This work reports a comprehensive approach for fabricating, actuating, sensing, and controlling a 180 mm‐long fibrous dielectric elastomer (DE) artificial muscle. The fabrication process introduces a novel method for patterning large‐area, uniform electrodes using vacuum filtration followed by mask‐free stamping on DE substrates. To address the challenge of long charging times that impair dynamic performance, an amplitude modulation algorithm is developed for high‐frequency actuation, which increased generated strain by 64% at a resonant frequency of 10 Hz. Additionally, the hollow space within the rolled artificial muscle is used to integrate a waveguide that serves as a strain sensor. This combined actuation‐sensing structure maintains flexibility and actuation capabilities while enabling self‐sensing and feedback control. The versatility of the DE artificial muscle is further demonstrated by segmenting a single long muscle into three shorter units and employing these units to construct two multi‐actuator machines: a tensegrity‐based gimbal and a rotary engine. This work advances the large‐scale production and application of DE artificial muscles.


  • Back Cover, Volume 42, Number 1, January 2025

    by Qi Shao, Qixing Xia, Zhonghan Lin, Xuguang Dong, Xin An, Haoqi Zhao, Zhangyi Li, Xin‐Jun Liu, Wenqiang Dong, Huichan Zhao

  • Unearthing the history with A‐RHex: Leveraging articulated hexapod robots for archeological pre‐exploration

    by Qi Shao, Qixing Xia, Zhonghan Lin, Xuguang Dong, Xin An, Haoqi Zhao, Zhangyi Li, Xin‐Jun Liu, Wenqiang Dong, Huichan Zhao

    This paper aims to develop a miniature mobile robot suitable to assist archeologists in their first exploration of unknown underground tombs. Due to the rather complex and irregular terrains in the tombs and inspired by the classic RHex design, we have developed a two‐segment articulated robot (A‐RHex) with two RHex design units. The robot is compact and lightweight, with dimensions of 25 cm long, 6.5 cm wide, 7 cm high, and weighs 283 g. To assist the robot in entering the tomb, we have also designed a deployment platform that can take the robots underground through a 10‐cm exploration hole. We introduce the overall design, control, and communication methods of A‐RHex, and theoretically analyze how the articulated design can improve the stability of the robot on slopes. Laboratory experiments and field testings at two real archeological excavation sites in China have validated A‐RHex's mechanical design, control strategies, communications, and capabilities for pre‐exploration of open and closed tombs. We believe that this kind of robot with high terrain adaptability and a small profile may become an important tool for field archeology in the future.


  • A Bio-Inspired Deformable Mouthpart Device With Adaptive Control for Negative Pressure Therapy on Unstructured Limb Surfaces

    by Zihao Li, Zhenguo Nie, Huichan Zhao, Qi Shao, Fugui Xie, Xin-Jun Liu

    Negative pressure (NP) therapy is effective in managing chronic lymphedema of the extremities. However, the seal formation of the general head (GH) can fail due to the interspace between the lip and the irregular skin surface on limbs before suction, resulting in the inefficiency of therapy, prolonging the time required for physiotherapy, and increasing the workload of physiotherapists. In this letter, we present a bio-inspired head (BIH) that uses adaptive control for NP therapy on unstructured surfaces. Its lip is designed with soft material inspired by the bloodworm to ensure safe human contact. Additionally, the lip size can be changed with the variation of the cavity pressure, and sensors on the lip could provide contact feedback. An adaptive control method is proposed for autonomous suction on unstructured surfaces. Several experiments were carried out to illustrate the characteristics of this novel head with a deformable lip and contact detection, while the adaptive control method for the NP suction on the unstructured surfaces was validated by phantom and body experiments. Compared with the GH, the results showed that the BIH with adaptive control could automatically fit the irregular arm structures to form a seal and complete the NP suction with a higher success rate(SR).


  • Top Cited Papers

    Active-Cooling-in-the-Loop Controller Design and Implementation for an SMA-Driven Soft Robotic Tentacle

    by Xin An, Yafeng Cui, Hao Sun, Qi Shao, Huichan Zhao

    As a classical type of smart materials, shape memory alloys (SMAs) are of high energy density, light weight, and low actuating voltage, and therefore are of great potential to be used as actuators for robots. Major challenges in controlling an SMA-driven soft robot are the limited bandwidth and in cases with external loads. Active cooling has been demonstrated to dramatically increase its bandwidth, but external load may cause severe inaccuracy in the system modeling. Controllers that do not rely on accurate modeling of the SMA-driven soft robot is essential. In this article, we designed an elastomeric soft robotic tentacle actuated by three pieces of SMA springs with both active heating (Joule heating) and active cooling (compressed air). We proposed a multi-input-multi-output controller that directly uses the heating and cooling states of the three SMAs to control the tentacle's bending posture in three-dimensional (3-D) space. The successful implementation of the controller is attributed to a novel dual-channel control algorithm that integrates the bending motion control and swing motion control, and a state-machine controller for coordinating the three SMAs' actuations to achieve robust swing motion control. The system with such hardware and control algorithm was capable of performing bending motions with maximum actuating speed $ $> 90 $^\circ /$ s, deactuating speed $ $> 25 $^\circ /$ s, closed-loop motions with rapidity (6–41 $^\circ /$ s for heating, 4–19 $^\circ /$ s for cooling), accuracy (steady-state error $ < $ 0.1 $^\circ$ for no load, 0.13 $\%$ of the full range; steady-state error $ < $ 1.2 $^\circ$ with load of 1 bodyweight, 1.6 $\%$ of the full range), and load-bearing capability (dynamic load: 1 bodyweight, static load: 8.8 bodyweights). Besides, the tentacle achieved efficient motion tracking by coordinating the bending and swing motion through the controller, for both predefined trajectories and random trajectories. We demonstrated a remotely controlled 360 $^\circ$ image scanning of a room using our proposed robotic tentacle equipped with a camera at its top end to intuitively show its performances. We believe this work will advance the design and control of SMA-driven soft continuum robots for potential uses in surgery and explorations of unknown areas.


  • Untethered Robotic Millipede Driven by Low-Pressure Microfluidic Actuators for Multi-Terrain Exploration

    by Qi Shao, Xuguang Dong, Zhonghan Lin, Chao Tang, Hao Sun, Xin-Jun Liu, Huichan Zhao

    Mobile robots that can adapt to an extensive range of terrains play essential roles in many applications. Millipedes are one of the most terrain-adaptive creatures in nature due to their multi-legged locomotion and flexible body. Inspired by natural millipedes, we report an untethered robotic millipede with a 6-segments soft-rigid hybrid body that can actively bend and 24 legs driven by low-pressure microfluidic actuators. The 24 microfluidic actuators are driven by two independent low-pressure sources from miniature pumps, which allows the untethered locomotion of the robotic millipede in small size (length, 23 cm; width, 5 cm; height, 4 cm) and lightweight (150 g). Using a pre-defined gait for the multi-legs, the robotic millipede can locomote with a maximum speed of 30.96 cm/min (1.35 body length per minute) and a minimum turning radius of 15 cm (0.65 body length). Experiments also demonstrated that the robot was able to locomote effectively in various uneven terrains. Utilizing its passive or active mode of its flexible body, the robot could also achieve adaptive moves. The robotic millipede has the potential to perform a variety of environment exploration tasks by remotely controlling and transmitting real-time images wirelessly.


  • Top Cited Papers

    A pipeline inspection robot for navigating tubular environments in the sub-centimeter scale

    by Chao Tang, Boyuan Du, Songwen Jiang, Qi Shao, Xuguang Dong, Xin-Jun Liu, Huichan Zhao

    In complex systems like aircraft engines and oil refinery machines, pipeline inspection is an essential task for ensuring safety. Here, we proposed a type of smart material–driven pipeline inspection robot (weight, 2.2 grams; length, 47 millimeters; diameter, <10 millimeters) that could fit into pipes with sub-centimeter diameters and different curvatures. We adopted high–power density, long-life dielectric elastomer actuators as artificial muscles and smart composite microstructure–based, high-efficiency anchoring units as transmissions. Fast assembling of components using magnets with an adjustable number of units was used to fit varying pipeline geometries. We analyzed the dynamic characteristics of the robots by considering soft material’s unique properties like viscoelasticity and dynamic vibrations and tuned the activation voltage’s frequency and phase accordingly. Powered by tethered cables from outside the pipe, our peristaltic pipeline robot achieved rapid motions horizontally and vertically (horizontal: 1.19 body lengths per second, vertical: 1.08 body lengths per second) in a subcentimeter-sized pipe (diameter, 9.8 millimeters). Besides, it was capable of moving in pipes with varying geometries (diameter-changing pipe, L-shaped pipe, S-shaped pipe, or spiral-shaped pipe), filled media (air or oil), and materials (glass, metal, or carbon fiber). To demonstrate its capability for pipeline inspection, we installed a miniature camera on its front and controlled the robot manually from outside. The robot successfully finished an inspection task at different speeds.