Zongguang Chen
Research Subjects
Zongguang Chen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Haisheng Chen
Institute of Engineering Thermophysics, Chinese Academy of Sciences
1 shared publication - Peng Li
Power China Zhongnan Engineering Corporation Limited, Changsha, China
1 shared publication - Xuezhi Zhou
Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Zhi Wang
School of Mechanics and Safety Engineering, ZhengZhou University Zhengzhou China
1 shared publication
Latest Publications
- Open Access
- 1 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (11) , 6788
Temperature Regulation Model and Experimental Study of Compressed Air Energy Storage Cavern Heat Exchange System
The first hard rock shallow-lined underground CAES cavern in China has been excavated to conduct a thermodynamic process and heat exchange system for practice. The thermodynamic equations for the solid and air region are compiled into the fluent two-dimensional axisymmetric model through user-defined functions. The temperature regulation model and experimental study results show that the charging time determines the air temperature and fluctuates dramatically under different charging flow rates. The average air temperature increases with increasing charging flow and decreasing charging time, fluctuating between 62.5 °C and −40.4 °C during the charging and discharging processes. The temperature would reach above 40 °C within the first 40 min of the initial pressurization stage, and the humidity decreases rapidly within a short time. The use of the heat exchange system can effectively control the cavern temperature within a small range (20–40 °C). The temperature rises and regularly falls with the control system’s switch. An inverse relationship between the temperature and humidity and water vapor can be seen in the first hour of the initial discharging. The maximum noise is 92 and 87 decibels in the deflation process.
- 1 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (11) , 6788
Open AccessTemperature Regulation Model and Experimental Study of Compressed Air Energy Storage Cavern Heat Exchange System
The first hard rock shallow-lined underground CAES cavern in China has been excavated to conduct a thermodynamic process and heat exchange system for practice. The thermodynamic equations for the solid and air region are compiled into the fluent two-dimensional axisymmetric model through user-defined functions. The temperature regulation model and experimental study results show that the charging time determines the air temperature and fluctuates dramatically under different charging flow rates. The average air temperature increases with increasing charging flow and decreasing charging time, fluctuating between 62.5 °C and −40.4 °C during the charging and discharging processes. The temperature would reach above 40 °C within the first 40 min of the initial pressurization stage, and the humidity decreases rapidly within a short time. The use of the heat exchange system can effectively control the cavern temperature within a small range (20–40 °C). The temperature rises and regularly falls with the control system’s switch. An inverse relationship between the temperature and humidity and water vapor can be seen in the first hour of the initial discharging. The maximum noise is 92 and 87 decibels in the deflation process.