Deepak Kumar Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Deepak Kumar Singh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ashok Kumar Akella
Department of Electrical Engineering National Institute of Technology Jamshedpur Jamshedpur Jharkhand 831014 India
5 shared publications- Saibal Manna
Department of Electrical Engineering, National Institute of Technology Jamshedpur, Jharkhand, India
5 shared publications Saibal Manna
Department of Electrical and Electronics Engineering ABES Engineering College Ghaziabad Uttar Pradesh 201009 India
3 shared publications- Ashok Kumar Akella
National Institute of Technology Jamshedpur
2 shared publications - Amr Yousef
Electrical Engineering Department, University of Business and Technology, Jeddah, Saudi Arabia
1 shared publication - Hossam Kotb
Department of Electrical Power and Machines, Faculty of Engineering, Alexandria University, Alexandria, Egypt
1 shared publication
Latest Publications
- 15 December 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Framework of Maximum Solar Energy Conversion Using Lyapunov‐Based Model Reference Adaptive Control Technique in Stochastic Weather Conditions
The solar photovoltaic (PV) energy generation technology has grown rapidly. Herein, a novel continuous‐time Lyapunov‐based model reference adaptive control (LB‐MRAC) technique is suggested for determining the duty cycle of boost converter to maintain maximum power point (MPP) of the solar PV panel. For ensuring the fast‐tracking speed, the reference voltage of, respectively, MPP is calculated using perturb and observe (PO) and input to the MRAC technique. Using MATLAB/Simulink, the performances of the LB‐MRAC maximum power point tracking are comparatively analyzed with PO, incremental conductance, and adaptive neuro‐fuzzy inference system under diverse testing modes such as stand‐alone, partial shading, grid integrated, and real time. The proposed technique tracks MPP in just 3.7 ms having tracking efficacy between 99.15% and 99.59% under highly fluctuating irradiance and temperature with load uncertainties. In partial shading mode, four patterns (3 × 1 PV string) are devised and determined where that the suggested approach monitors the global MPP in merely 0.04 s with the highest power tracked and the least amount of shading loss. Next, the efficacy is checked in a three‐phase 50 kW grid‐integrated mode under realistic weather. Finally, the performance of the suggested continuous‐time LB‐MRAC technique is experimentally corroborated employing OPAL‐RT(OP4510) in the real‐time mode.
- 15 December 2023
- Published by Wiley in Energy Technology
- Vol. 12 (2)
Framework of Maximum Solar Energy Conversion Using Lyapunov‐Based Model Reference Adaptive Control Technique in Stochastic Weather Conditions
The solar photovoltaic (PV) energy generation technology has grown rapidly. Herein, a novel continuous‐time Lyapunov‐based model reference adaptive control (LB‐MRAC) technique is suggested for determining the duty cycle of boost converter to maintain maximum power point (MPP) of the solar PV panel. For ensuring the fast‐tracking speed, the reference voltage of, respectively, MPP is calculated using perturb and observe (PO) and input to the MRAC technique. Using MATLAB/Simulink, the performances of the LB‐MRAC maximum power point tracking are comparatively analyzed with PO, incremental conductance, and adaptive neuro‐fuzzy inference system under diverse testing modes such as stand‐alone, partial shading, grid integrated, and real time. The proposed technique tracks MPP in just 3.7 ms having tracking efficacy between 99.15% and 99.59% under highly fluctuating irradiance and temperature with load uncertainties. In partial shading mode, four patterns (3 × 1 PV string) are devised and determined where that the suggested approach monitors the global MPP in merely 0.04 s with the highest power tracked and the least amount of shading loss. Next, the efficacy is checked in a three‐phase 50 kW grid‐integrated mode under realistic weather. Finally, the performance of the suggested continuous‐time LB‐MRAC technique is experimentally corroborated employing OPAL‐RT(OP4510) in the real‐time mode.
- Open Access
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 118268-118280
Probabilistic Bi-Level Assessment and Adaptive Control Mechanism for Two-Tank Interacting System
Liquid level control is a fundamental aspect employed across various industries, where the precise regulation of liquid levels and flow rates is of utmost importance. The Proportional-integral-derivative (PID)controller is widely employed but in practice, the operation of a PID may not always align with the desired outcome due to various factors such as system dynamic behavior, model uncertainties, time-varying parameters, and disturbances. To effectively address these challenges, the article proposes model reference adaptive control (MRAC) based on the Massachusetts Institute of technology (MIT) law feedback PID technique for a two-tank interacting system. The detailed comparative analysis is carried out in MATLAB/Simulink with open loop, PID, and MRAC in respect of time domain specifications. The proposed approach stability is verified using the Lyapunov approach. The robustness of the control mechanism is validated through probabilistic assessment by introducing a bi-level uncertainty framework such as gain mistuning and dynamic system behavior. In the first level, the gain mistuning is accomplished in three aspects i.e., fine-tuned, increased, and decrease gain. In the second level, it is considered that system behavior is dynamic in nature. Based on the findings, the MRAC-PID exhibits superior performance against uncertainties as compared to PID and MRAC with enhanced tracking rapidity, accuracy, and robustness.
- 23 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 118268-118280
Open AccessProbabilistic Bi-Level Assessment and Adaptive Control Mechanism for Two-Tank Interacting System
Liquid level control is a fundamental aspect employed across various industries, where the precise regulation of liquid levels and flow rates is of utmost importance. The Proportional-integral-derivative (PID)controller is widely employed but in practice, the operation of a PID may not always align with the desired outcome due to various factors such as system dynamic behavior, model uncertainties, time-varying parameters, and disturbances. To effectively address these challenges, the article proposes model reference adaptive control (MRAC) based on the Massachusetts Institute of technology (MIT) law feedback PID technique for a two-tank interacting system. The detailed comparative analysis is carried out in MATLAB/Simulink with open loop, PID, and MRAC in respect of time domain specifications. The proposed approach stability is verified using the Lyapunov approach. The robustness of the control mechanism is validated through probabilistic assessment by introducing a bi-level uncertainty framework such as gain mistuning and dynamic system behavior. In the first level, the gain mistuning is accomplished in three aspects i.e., fine-tuned, increased, and decrease gain. In the second level, it is considered that system behavior is dynamic in nature. Based on the findings, the MRAC-PID exhibits superior performance against uncertainties as compared to PID and MRAC with enhanced tracking rapidity, accuracy, and robustness.
- 1 September 2023
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 36 (3) , 1171-1185
Design and Implementation of MRAC & MRAC-PID Feedback for Turntable
The paper explains a control method for turntable by feedback a PID controller with the traditional model reference adaptive controller (MRAC) based on the MIT rule. The traditional MRAC is designed for a first-order system with the adjustment of a two-variable parameter. However, the majority of plants, including turntable, are second-order systems. Traditional MRAC tracking performance for second-order systems is unsatisfactory. The control law for the second order system along with extension from the first to the second order of MRAC is derived. The modified MRAC i.e., MRAC-PID controller is designed for the application of turntable. It enhanced the system’s dynamic performance. To assess the performance of the proposed controller, MATLAB/Simulink software was used. The article incorporates a detailed analysis and comparison of PID, MRAC as well as MRAC-PID controllers based on the MIT rule for the turntable system. The robustness of the proposed controller is validated by introducing uncertainties in two aspects i.e., mistuning of the controller gains and turntable system dynamics change. The probabilistic design assessment for the mistuning is carried out through levels of uncertainty in controller gain. It is observed that PID and MRAC would track the reference model but modified MRAC has better performance in terms of tracking accuracy, adaptability, and rapidity. Several performance indexes such as integral absolute error (IAE), integral time absolute error (ITAE), and integral square error (ISE) were employed to justify the proposed controller superiority.
- 1 September 2023
- Published by Gazi University Journal of Science in Gazi University Journal of Science
- Vol. 36 (3) , 1171-1185
Design and Implementation of MRAC & MRAC-PID Feedback for Turntable
The paper explains a control method for turntable by feedback a PID controller with the traditional model reference adaptive controller (MRAC) based on the MIT rule. The traditional MRAC is designed for a first-order system with the adjustment of a two-variable parameter. However, the majority of plants, including turntable, are second-order systems. Traditional MRAC tracking performance for second-order systems is unsatisfactory. The control law for the second order system along with extension from the first to the second order of MRAC is derived. The modified MRAC i.e., MRAC-PID controller is designed for the application of turntable. It enhanced the system’s dynamic performance. To assess the performance of the proposed controller, MATLAB/Simulink software was used. The article incorporates a detailed analysis and comparison of PID, MRAC as well as MRAC-PID controllers based on the MIT rule for the turntable system. The robustness of the proposed controller is validated by introducing uncertainties in two aspects i.e., mistuning of the controller gains and turntable system dynamics change. The probabilistic design assessment for the mistuning is carried out through levels of uncertainty in controller gain. It is observed that PID and MRAC would track the reference model but modified MRAC has better performance in terms of tracking accuracy, adaptability, and rapidity. Several performance indexes such as integral absolute error (IAE), integral time absolute error (ITAE), and integral square error (ISE) were employed to justify the proposed controller superiority.
- 9 July 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 3751-3772
Adjustable variable step-based MRAC MPPT for solar PV system in highly fluctuating and cloudy atmospheric conditions
- 9 July 2023
- Published by Springer Nature in Electrical Engineering
- Vol. 105 (6) , 3751-3772
Adjustable variable step-based MRAC MPPT for solar PV system in highly fluctuating and cloudy atmospheric conditions
- 4 April 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (5)
A novel robust maximum power extraction framework for sustainable PV system using incremental conductance based MRAC technique
This study proposes a maximum power point tracking (MPPT) approach with two components: an Incremental Conductance (INC) MPPT for reference voltage regulation and a Model Reference Adaptive Controller (MRAC) for adjusting the duty cycle of the DC‐DC converter switch. A robustness test is performed on the system considering real‐world situations that involve an abrupt change in atmospheric conditions with load uncertainties. The probabilistic load distribution analysis is accomplished through levels of uncertainty (i.e., Probabilistic DOWN and UP) to guarantee the operation of the proposed INC‐MRAC controller while generating unexpected disturbances in the system. Using MATLAB/Simulink, the performances of the novel INC‐MRAC MPPT are comparatively analyzed with PO, INC, VSSPO, and ANN under realistic case studies in seven states. After comparative analysis, it is evident that the proposed MPPT offers less tracking time, i.e., 3.8 ms, to track maximum power point (MPP) with negligible steady‐state oscillation and ripples. It is about 3, 7, 9, and 10 times faster than ANN, VSSPO, INC and PO, respectively. Moreover, the tracking efficiency of the proposed controller is up to 99.63% as well as overall efficiency of the system is more than 98%. The tracking power loss and error rate in finding MPP for the proposed controller is the lowest among all state‐of‐the‐art MPPT approaches. Finally, the effectiveness of the proposed INC‐MRAC approach is experimentally validated by employing a real‐time simulator OPAL‐RT (OP4510). The study helps in environmental protection and participation in sustainable development.
- 4 April 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (5)
A novel robust maximum power extraction framework for sustainable PV system using incremental conductance based MRAC technique
This study proposes a maximum power point tracking (MPPT) approach with two components: an Incremental Conductance (INC) MPPT for reference voltage regulation and a Model Reference Adaptive Controller (MRAC) for adjusting the duty cycle of the DC‐DC converter switch. A robustness test is performed on the system considering real‐world situations that involve an abrupt change in atmospheric conditions with load uncertainties. The probabilistic load distribution analysis is accomplished through levels of uncertainty (i.e., Probabilistic DOWN and UP) to guarantee the operation of the proposed INC‐MRAC controller while generating unexpected disturbances in the system. Using MATLAB/Simulink, the performances of the novel INC‐MRAC MPPT are comparatively analyzed with PO, INC, VSSPO, and ANN under realistic case studies in seven states. After comparative analysis, it is evident that the proposed MPPT offers less tracking time, i.e., 3.8 ms, to track maximum power point (MPP) with negligible steady‐state oscillation and ripples. It is about 3, 7, 9, and 10 times faster than ANN, VSSPO, INC and PO, respectively. Moreover, the tracking efficiency of the proposed controller is up to 99.63% as well as overall efficiency of the system is more than 98%. The tracking power loss and error rate in finding MPP for the proposed controller is the lowest among all state‐of‐the‐art MPPT approaches. Finally, the effectiveness of the proposed INC‐MRAC approach is experimentally validated by employing a real‐time simulator OPAL‐RT (OP4510). The study helps in environmental protection and participation in sustainable development.
- 19 February 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (1) , 1321-1345
Implementation of a novel robust model reference adaptive controller-based MPPT for stand-alone and grid-connected photovoltaic system
The fast advancement of photovoltaic (PV) power generation technologies led to the integration of solar-based generation systems into several modes of transportation, including aircraft, automobiles, and trains. In these PV systems, solar irradiation levels fluctuate significantly and invalidate specific maximum power point (MPP) tracking (MPPT) control strategies, lowering the energy conversion efficiency. It is evident that the new robust model reference adaptive control (MRAC) proposed in this paper alleviates these problems by reducing tracking direction loss and oscillations near MPP. To evaluate the proposed controller’s performance, MATLAB/Simulink is utilized and compared with well-known techniques (P&O, VSPO, INC, ANFIS, and swarm-based MPPT) under three different modes, i.e. stand-alone, grid-connected, and real-time mode. The proposed scheme has tracking efficacy lies between 99.02% and 99.96% and achieved MPP in just 4 msec under highly fluctuating radiation and temperature conditions. It takes only 0.08 sec to capture the global MPP, which is on average two times faster than swarm-based global MPPT methods. Furthermore, the effectiveness is tested in a 50 kW three-phase grid-connected mode with and without cloud effects in realistic weather situations. Finally, real-time validation on the OPAL-RT simulator demonstrates the proposed technique’s practicality in real-world applications.
- 19 February 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (1) , 1321-1345
Implementation of a novel robust model reference adaptive controller-based MPPT for stand-alone and grid-connected photovoltaic system
The fast advancement of photovoltaic (PV) power generation technologies led to the integration of solar-based generation systems into several modes of transportation, including aircraft, automobiles, and trains. In these PV systems, solar irradiation levels fluctuate significantly and invalidate specific maximum power point (MPP) tracking (MPPT) control strategies, lowering the energy conversion efficiency. It is evident that the new robust model reference adaptive control (MRAC) proposed in this paper alleviates these problems by reducing tracking direction loss and oscillations near MPP. To evaluate the proposed controller’s performance, MATLAB/Simulink is utilized and compared with well-known techniques (P&O, VSPO, INC, ANFIS, and swarm-based MPPT) under three different modes, i.e. stand-alone, grid-connected, and real-time mode. The proposed scheme has tracking efficacy lies between 99.02% and 99.96% and achieved MPP in just 4 msec under highly fluctuating radiation and temperature conditions. It takes only 0.08 sec to capture the global MPP, which is on average two times faster than swarm-based global MPPT methods. Furthermore, the effectiveness is tested in a 50 kW three-phase grid-connected mode with and without cloud effects in realistic weather situations. Finally, real-time validation on the OPAL-RT simulator demonstrates the proposed technique’s practicality in real-world applications.
- 9 November 2022
- Published by Springer Nature
- p. 221-236
Comparison of Various Empirical Models to Estimate Monthly Mean Diffuse Solar Radiation for Humid-Subtropical Climate Region of India
- 9 November 2022
- Published by Springer Nature
- p. 221-236
Comparison of Various Empirical Models to Estimate Monthly Mean Diffuse Solar Radiation for Humid-Subtropical Climate Region of India
- 7 June 2022
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 41 (6)
Deterministic and probabilistic analysis of different empirical models to estimate monthly mean diffuse solar radiation for composite climatic region of India
This research compares the performance of the models to estimate monthly mean diffuse solar radiation (DSR) on a horizontal surface for composite climatic region of India. The goal is to identify the most accurate model using deterministic and probabilistic analysis through two levels of uncertainty in daily sunshine period to examine the accuracy of the model that will be used to estimate DSR in the region under consideration. The meteorological data were collected from Indian Meteorological Department for the city of New Delhi (28°34′N, 77°12′E) which comes under composite climatic region prescribed by the Energy Conservation Building Code for India. From the literature, 150 typical models were chosen and categorized into three categories correlating diffuse fraction to sky‐clearness index and relative sunshine period. The models are statistically evaluated using well‐known statistical indicators in a unique way. In addition, the global performance indicator (GPI) is calculated using scaled values of indicators. The GPI of the chosen models ranged from −2.2912 to 0.2584, with the greatest value indicating the best model. Following that, the models are then ranked in decreasing order of GPI. Finally, the performances of the models are also checked for different locations having similar climatic conditions. Thus, results of this work are useful for impoverished countries as well as remote areas having similar environment conditions.
- 7 June 2022
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 41 (6)
Deterministic and probabilistic analysis of different empirical models to estimate monthly mean diffuse solar radiation for composite climatic region of India
This research compares the performance of the models to estimate monthly mean diffuse solar radiation (DSR) on a horizontal surface for composite climatic region of India. The goal is to identify the most accurate model using deterministic and probabilistic analysis through two levels of uncertainty in daily sunshine period to examine the accuracy of the model that will be used to estimate DSR in the region under consideration. The meteorological data were collected from Indian Meteorological Department for the city of New Delhi (28°34′N, 77°12′E) which comes under composite climatic region prescribed by the Energy Conservation Building Code for India. From the literature, 150 typical models were chosen and categorized into three categories correlating diffuse fraction to sky‐clearness index and relative sunshine period. The models are statistically evaluated using well‐known statistical indicators in a unique way. In addition, the global performance indicator (GPI) is calculated using scaled values of indicators. The GPI of the chosen models ranged from −2.2912 to 0.2584, with the greatest value indicating the best model. Following that, the models are then ranked in decreasing order of GPI. Finally, the performances of the models are also checked for different locations having similar climatic conditions. Thus, results of this work are useful for impoverished countries as well as remote areas having similar environment conditions.