Mukesh Ghosh
Mukesh Ghosh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mukesh Ghosh has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Passaretti
Research Campus STIMULATE, Otto von Guericke University Magdeburg, Magdeburg, Germany
1 shared publication - Micaela Lambru Egito
Institute for Information Technology and Communications, Otto von Guericke University Magdeburg, 39106 Magdeburg, Germany
1 shared publication - Shiras Abdurahman
Institute for Medical Engineering and Research Campus STIMULATE, Otto-von-Guericke-Universitt, Magdeburg, Germany
1 shared publication - Thilo Pionteck
Institute for Information Technology and Communications, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
1 shared publication
Latest Publications
- Open Access
- 2 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (11) , 5659
Hardware Optimizations of the X-ray Pre-Processing for Interventional Computed Tomography Using the FPGA
In computed tomography imaging, the computationally intensive tasks are the pre-processing of 2D detector data to generate total attenuation or line integral projections and the reconstruction of the 3D volume from the projections. This paper proposes the optimization of the X-ray pre-processing to compute total attenuation projections by avoiding the intermediate step to convert detector data to intensity images. In addition, to fulfill the real-time requirements, we design a configurable hardware architecture for data acquisition systems on FPGAs, with the goal to have a “on-the-fly” pre-processing of 2D projections. Finally, this architecture was configured for exploring and analyzing different arithmetic representations, such as floating-point and fixed-point data formats. This design space exploration has allowed us to find the best representation and data format that minimize execution time and hardware costs, while not affecting image quality. Furthermore, the proposed architecture was integrated in an open-interface computed tomography device, used for evaluating the image quality of the pre-processed 2D projections and the reconstructed 3D volume. By comparing the proposed solution with the state-of-the-art pre-processing algorithm that make use of intensity images, the latency was decreased 4.125×, and the resources utilization of ∼6.5×, with a mean square error in the order of for all the selected phantom experiments. Finally, by using the fixed-point representation in the different data precisions, the latency and the resource utilization were further decreased, and a mean square error in the order of was reached.- 2 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (11) , 5659
Open AccessHardware Optimizations of the X-ray Pre-Processing for Interventional Computed Tomography Using the FPGA
In computed tomography imaging, the computationally intensive tasks are the pre-processing of 2D detector data to generate total attenuation or line integral projections and the reconstruction of the 3D volume from the projections. This paper proposes the optimization of the X-ray pre-processing to compute total attenuation projections by avoiding the intermediate step to convert detector data to intensity images. In addition, to fulfill the real-time requirements, we design a configurable hardware architecture for data acquisition systems on FPGAs, with the goal to have a “on-the-fly” pre-processing of 2D projections. Finally, this architecture was configured for exploring and analyzing different arithmetic representations, such as floating-point and fixed-point data formats. This design space exploration has allowed us to find the best representation and data format that minimize execution time and hardware costs, while not affecting image quality. Furthermore, the proposed architecture was integrated in an open-interface computed tomography device, used for evaluating the image quality of the pre-processed 2D projections and the reconstructed 3D volume. By comparing the proposed solution with the state-of-the-art pre-processing algorithm that make use of intensity images, the latency was decreased 4.125×, and the resources utilization of ∼6.5×, with a mean square error in the order of for all the selected phantom experiments. Finally, by using the fixed-point representation in the different data precisions, the latency and the resource utilization were further decreased, and a mean square error in the order of was reached.