MJMin-Seung Jo

Min-Seung Jo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Min-Seung Jo has a total of 99 co-authors. Here are the top co-authors by number of shared publications:

  • Jun-Bo Yoon

    Korea Advanced Institute of Science and Technology

    5 shared publications
  • Jae-Young Yoo

    Department of Semiconductor Convergence Engineering, Sungkyunkwan University, 2066, Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do 16417, Republic of Korea

    4 shared publications
  • Jae-Young Yoo

    Department of Semiconductor Convergence Engineering, Sungkyunkwan University, Suwon, Republic of Korea

    3 shared publications
  • John A. Rogers

    Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA

    3 shared publications
  • Kwang-Wook Choi

    School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea

    3 shared publications
  • Sung-Ho Kim

    School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea

    3 shared publications

Latest Publications

  • Open Access

    A compact, wireless fluorimeter system for continuous, real-time monitoring of tissue perfusion via in vivo fluorescence signals

    by Tae Wan Park, Haohui Zhang, Chanho Park, Seth D. Goldstein, Lindsey Wade, Eric Rytkin, Alicia J. McLuckie, Yalcin Kulahci, Ramu Janarthanan, Tae Yeon Kim, et al.

    In vivo fluorescence signals provide physiological and pathological insights for the interpretation of biological states associated with anatomical abnormalities or disease. Conventional methods for measuring fluorescence signals rely on bulky, costly instrumentation for imaging or for localized sensing. Here, we report a compact, wireless fluorimeter system for continuous, real-time measurements of the dynamics of fluorescence signals at locations of interest across the body. The approach represents a type of wearable that enables quantitative, interpretable fluorescence readouts and automatic data streaming to standard smart devices. The platform is compatible with injectable fluorescent species of medical relevance, such as indocyanine green, fluorescein, and methylene blue. Measurements from ischemic rodent and healthy porcine models, as well as those associated with limb amputation/replantation studies in rodents, demonstrate physiologically meaningful fluorescence profiles, with validation against ex situ blood analysis. These conceptual and technical advances offer the potential for convenient, continuous monitoring of fluorescence signals to support disease management and long-term patient care.


  • Open Access

    Shape memory polymer adhesives for on-demand, low-force detachment in skin-interfaced devices

    by ChangHee Son, Uhyeon Kim, Hyein Jung, Jay Young Kwak, Junhyung Kim, Katherine R. Jinkins, Claire Liu, Min-Seung Jo, John A. Rogers, Seok Kim, et al.

    Skin-interfaced biomedical devices require adhesives that provide strong attachment during use while enabling gentle removal with minimized subsurface skin deformation. Conventional medical adhesives lack mechanisms for on-demand adhesion modulation, often causing skin irritation and damage during detachment, particularly in vulnerable populations. Here, we present a thermally triggered shape memory polymer (SMP) adhesive that achieves reversible, high-contrast adhesion switching through programmable pyramidal structure recovery. The adhesive incorporates an array of pyramidal structures that remain flattened in a dormant state to ensure robust skin adhesion, but rapidly recover upon mild heating above the glass transition temperature, significantly reducing effective contact area and enabling low-force detachment. Adhesion switchability performances are supported by quantitative mechanical measurements, including reductions in peel force and adhesion energy after activation, as well as three-dimensional digital image correlation (3D-DIC) analyses demonstrating minimal subsurface skin deformation during detachment. Mechanical testing demonstrates up to ~99% reduction in adhesion energy upon activation, while maintaining stable load-bearing performance during use. 3D-DIC shows that the actuated SMP suppresses stress concentrations and minimizes subsurface skin deformation during detachment, unlike the dormant SMP. A kirigami structural design further enhances conformability on both singly and doubly curved anatomical surfaces while improving water vapor permeability. Finite element analysis and 3D-DIC measurements reveal substantial reductions in effective stiffness and enhanced bending accommodation enabled by the kirigami geometry. Integration with wireless mechano-acoustic sensors confirms reliable physiological signal acquisition in the dormant state and controlled detachment upon activation. This work establishes a thermally switchable SMP adhesive platform for low-force removal of skin-interfaced devices.

  • Open Access

    A wearable biomechanical system for medical evaluation of soft tissue disorders.

    by Min-Seung Jo, Hee-Sup Shin, Jin-Tae Kim, Shupeng Li, Sonwoo Jung, Jungyeon Kim, Tae Wan Park, Jodi L Johnson, Carrie Richardson, Eseosa Olive Osaghae, et al.

    Evaluating soft tissue elasticity provides critical biomechanical insights essential for the precise characterization of various physiological and pathological conditions. Here, we present the clinical validation of a wireless, compact wearable system designed for direct, location-specific monitoring of the elastic modulus of the skin and underlying tissues via vibro-rotational biomechanical dynamics. Validated by computational models and experiments, the device uses a tunable skin interface to enable depth-controlled measurements across diverse anatomical sites. Two human subject studies, one involving patients with cancer-related lymphedema and the other involving patients with systemic scleroderma, yield data that correlate with standard clinical metrics. This technology offers the potential for longitudinal assessments in these and other contexts, in both clinical and home settings.


  • Open Access

    Wireless, skin-interfaced multimodal sensing system for continuous psychophysiological monitoring—A wearable polygraph device

    by Sun Hong Kim, Tae Wan Park, Seunghee Cho, Tianyu Yang, Seonggwang Yoo, Khaytin Ilya, Jacie R. McHaney, Jana Jaffe, Anisha Kshetrapal, Yue Wang, et al.

    Accurate, continuous monitoring of psychophysiological states is central to understanding stress and autonomic dysfunction across diverse medical contexts. Current approaches such as polygraphy and polysomnography rely on cumbersome, wired sensors that limit real-world utility and burden patients, particularly vulnerable populations such as infants. Here, we introduce a wireless, skin-interfaced multimodal sensing system capable of simultaneously recording cardiac, respiratory, electrodermal, and thermal signals in a time-synchronized manner. Leveraging compact and soft designs, the technology enables unobtrusive monitoring across controlled, clinical, and naturalistic settings. Validation studies performed in parallel with gold standard systems demonstrate high fidelity in quantifying stress responses during polygraph interviews, cognitive load tasks, and cold pressor tests. In pediatric sleep studies, the data reliably identify arousals, hypopnea, and apnea while revealing disease-specific autonomic signatures in infants with Down syndrome. Real-world deployment during emergency simulation training shows that multimodal stress signatures correlate inversely with performance, underscoring translational value in medical education. Machine learning analyses across all studies confirm that multimodal features outperform single-signal approaches in detecting stress and clinical events with high sensitivity and specificity. Collectively, these findings establish the technology as a next-generation wearable platform that bridges engineering innovation and clinical practice, offering mechanistic insight and diagnostic potential in stress medicine, sleep medicine, and beyond.


  • Perfectly Spatial and Shape-Controllable Nanocrack Lithography via Localized Compressive-Shear Stress Coupling

    by Xu Tian, Sang-Min Kim, Jae-Young Yoo, Min-Seung Jo, Jun-Bo Yoon, Min-Ho Seo

    Cracking-assisted nanofabrication techniques have gained widespread applications across diverse engineering fields for the creation of nanoscale features, valued for their simplicity, cost-effectiveness, and high resolution. However, conventional methods often struggle to control the density, shape, and uniformity of nanocracks due to random stress concentrations caused by material defects and uncontrolled mechanical stress distribution during nanocrack formation. To address these limitations, we developed a highly reliable and reproducible nanocrack patterning method capable of creating large-scale, customizable nanocrack patterns on flexible substrates via the compressive-shear stress coupling effect. Our approach utilizes photolithography-based microphotoresist structures and simultaneous bending and pressing to induce highly localized stresses at the corners of the structures, facilitating the formation of nanocracks. This method enables precise spatial and shape control of nanocrack patterns in functional materials on flexible substrates. For example, in platinum films on polymer substrates, we achieved a uniform and consistent average nanocrack spacing of 40 μm with a standard deviation as low as 0.1 μm across 100 parallel nanocracks. The technique is versatile and can be applied to various functional materials, such as copper and indium tin oxide. We further showed the creation of diverse curved and closed-shape nanocracks, including zigzag, wave, square, circle, parallelogram, and cross shapes, in copper thin films. Finally, we applied this method to various engineering fields to demonstrate its efficacy, including strain sensors with gauge factors of approximately 380, a three-dimensional pressure sensor array capable of reliably measuring pressures below 0.1 N, and nanowire patterning with highly uniform spacing (40 ± 0.5 μm) on polymer substrates that offered both flexibility and transparency.


  • Fast-Response and Low-Power Self-Heating Gas Sensor Using Metal/Metal Oxide/Metal (MMOM) Structured Nanowires

    by Min-Seung Jo, Sung-Ho Kim, So-Yoon Park, Kwang-Wook Choi, Sang-Hee Kim, Jae-Young Yoo, Beom-Jun Kim, Jun-Bo Yoon

    With the escalating global awareness of air quality management, the need for continuous and reliable monitoring of toxic gases by using low-power operating systems has become increasingly important. One of which, semiconductor metal oxide gas sensors have received great attention due to their high/fast response and simple working mechanism. More specifically, self-heating metal oxide gas sensors, wherein direct thermal activation in the sensing material, have been sought for their low power-consuming characteristics. However, previous works have neglected to address the temperature distribution within the sensing material, resulting in inefficient gas response and prolonged response/recovery times, particularly due to the low-temperature regions. Here, we present a unique metal/metal oxide/metal (MMOM) nanowire architecture that conductively confines heat to the sensing material, achieving high uniformity in the temperature distribution. The proposed structure enables uniform thermal activation within the sensing material, allowing the sensor to efficiently react with the toxic gas. As a result, the proposed MMOM gas sensor showed significantly enhanced gas response (from 6.7 to 20.1% at 30 ppm), response time (from 195 to 17 s at 30 ppm), and limit of detection (∼1 ppm) when compared to those of conventional single-material structures upon exposure to carbon monoxide. Furthermore, the proposed work demonstrated low power consumption (2.36 mW) and high thermal durability (1500 on/off cycles), demonstrating its potential for practical applications in reliable and low-power operating gas sensor systems. These results propose a new paradigm for power-efficient and robust self-heating metal oxide gas sensors with potential implications for other fields requiring thermal engineering.


  • Ultrafast (∼0.6 s), Robust, and Highly Linear Hydrogen Detection up to 10% Using Fully Suspended Pure Pd Nanowire

    by Min-Seung Jo, Ki-Hoon Kim, Jae-Shin Lee, Sung-Ho Kim, Jae-Young Yoo, Kwang-Wook Choi, Beom-Jun Kim, Dae-Sung Kwon, Ilseon Yoo, Jae-Soon Yang, et al.

    The high explosiveness of hydrogen gas in the air necessitates prompt detection in settings where hydrogen is used. For this reason, hydrogen sensors are required to offer rapid detection and possess superior sensing characteristics in terms of measurement range, linearity, selectivity, lifetime, and environment insensitivity according to the publicized protocol. However, previous approaches have only partially achieved the standardized requirements and have been limited in their capability to develop reliable materials for spatially accessible systems. Here, an electrical hydrogen sensor with an ultrafast response (∼0.6 s) satisfying all demands for hydrogen detection is demonstrated. Tailoring structural engineering based on the reaction kinetics of hydrogen and palladium, an optimized heating architecture that thermally activates fully suspended palladium (Pd) nanowires at a uniform temperature is designed. The developed Pd nanostructure, at a designated temperature distribution, rapidly reacts with hydrogen, enabling a hysteresis-free response from 0.1% to 10% and durable characteristics in mechanical shock and repetitive operation (>10,000 cycles). Moreover, the device selectively detects hydrogen without performance degradation in humid or carbon-based interfering gas circumstances. Finally, to verify spatial accessibility, the wireless hydrogen detection system has been demonstrated, detecting and reporting hydrogen leakage in real-time within just 1 s.


  • Wireless and Linear Hydrogen Detection up to 4% with High Sensitivity through Phase-Transition-Inhibited Pd Nanowires

    by Min-Seung Jo, Ki-Hoon Kim, Kwang-Wook Choi, Jae-Shin Lee, Jae-Young Yoo, Sung-Ho Kim, Heejeong Jin, Min-Ho Seo, Jun-Bo Yoon

    Palladium (Pd) has been drawing increasing attention as a hydrogen (H2) detecting material due to its highly selective sensitivity to H2. However, at H2 concentrations above 2%, Pd undergoes an inevitable phase transition, causing undesirable electrical and mechanical alterations. In particular, nonlinear gas response (ΔR/R0) that accompanies phase transition has been a great bottleneck for detecting H2 in high concentrations, which is especially important as there is a risk of explosion over 4% H2. Here, we propose a phase-transition-inhibited Pd nanowire H2 sensor that can detect up to 4% H2 with high linearity and high sensitivity. Based on the calculation of the change in free energy, we designed Pd nanowires that are highly adhered to the substrate to withstand the stress that leads to phase transition. We theoretically optimized the Pd nanowire dimensions using a finite element method simulation and then experimentally fabricated the proposed sensor by exploiting a developed nanofabrication method. The proposed sensor exhibits a high sensing linearity (98.9%) with high and stable sensitivity (ΔR/R0/[H2] = 875%·bar-1) over a full range of H2 concentrations (0.1-4%). Using the fabricated Pd sensors, we have successfully demonstrated a wireless sensor module that can detect H2 with high linearity, notifying real-time H2 leakage through remote communication. Overall, our work suggests a nanostructuring strategy for detecting H2 with a phase-transition-inhibited pure Pd H2 sensor with rigorous scientific exploration.


  • Material-Independent Nanotransfer onto a Flexible Substrate Using Mechanical-Interlocking Structure

    by Min-Ho Seo, Seon-Jin Choi, Sang Hyun Park, Jae-Young Yoo, Sung Kyu Lim, Jae-Shin Lee, Kwang-Wook Choi, Min-Seung Jo, Il-Doo Kim, Jun-Bo Yoon

    Nanowire-transfer technology has received much attention thanks to its capability to fabricate high-performance flexible nanodevices with high simplicity and throughput. However, it is still challenging to extend the conventional nanowire-transfer method to the fabrication of a wide range of devices since a chemical-adhesion-based nanowire-transfer mechanism is complex and time-consuming, hindering successful transfer of diverse nanowires made of various materials. Here, we introduce a material-independent mechanical-interlocking-based nanowire-transfer (MINT) method, fabricating ultralong and fully aligned nanowires on a large flexible substrate (2.5 × 2 cm2) in a highly robust manner. For the material-independent nanotransfer, we developed a mechanics-based nanotransfer method, which employs a dry-removable amorphous carbon (a-C) sacrificial layer between a vacuum-deposited nanowire and the underlying master mold. The controlled etching of the sacrificial layer enables the formation of a mechanical-interlocking structure under the nanowire, facilitating peeling off of the nanowire from the master mold robustly and reliably. Using the developed MINT method, we successfully fabricated various metallic and semiconductor nanowire arrays on flexible substrates. We further demonstrated that the developed method is well suited to the reliable fabrication of highly flexible and high-performance nanoelectronic devices. As examples, a fully aligned gold (Au) microheater array exhibited high bending stability (106 cycling) and ultrafast (∼220 ms) heating operation up to ∼100 °C. An ultralong Au heater-embedded cuprous-oxide (Cu2O) nanowire chemical gas sensor showed significantly improved reversible reaction kinetics toward NO2 with 10-fold enhancement in sensitivity at 100 °C.